| Literature DB >> 35284326 |
Lilian Tietz1, Renan Diego Furlan2, Ricardo Abreu da Rosa1, Marco Antonio Hungaro Duarte2, Murilo Priori Alcalde3, Rodrigo Ricci Vivan2, Theodoro Weissheimer1, Marcus Vinicius Reis Só1.
Abstract
Objectives: This study evaluated the efficacy of 3 reciprocating systems and the effects of 2 instruments for irrigant activation on filling material removal. Materials andEntities:
Keywords: Endodontic; Micro computed tomography; Reciprocating; Retreatment
Year: 2022 PMID: 35284326 PMCID: PMC8891472 DOI: 10.5395/rde.2022.47.e13
Source DB: PubMed Journal: Restor Dent Endod ISSN: 2234-7658
Figure 1Flowchart representing all stages of the experimental procedures.
Micro-CT, micro-computed tomography.
Comparative analysis of the volume of filling material (mm3) after each retreatment stage and the time required to reach the working length
| Variables | Manual | Reciproc Blue | WaveOne Gold | X1 Blue |
|---|---|---|---|---|
| After root canal obturation | 3.35Aa (1.58–9.21) | 4.03Aa (2.17–6.69) | 3.61Aa (2.41–5.47) | 3.82Aa (1.34–7.26) |
| After filling removal | 2.47Aa (0.79–5.16) | 1.33ABb (0.35–2.97) | 0.95Bb (0.01–1.72) | 1.14ABb (0.67–3.04) |
| After repreparation | 1.15Ab (0.50–4.79) | 1.04Ab (0.29–2.58) | 0.77Ab (0.01–1.09) | 0.96Ab (0.59–2.90) |
| Time required to reach the working length (in seconds) | 325B (178–773) | 239AB (93–477) | 147AB (66–195) | 100A (66–332) |
The numbers represent the median (minimum–maximum) values.
Different uppercase letters in the line denote a statistically significant difference according to the Kruskal-Wallis and Dunn post hoc tests. Different lowercase letters in the column indicate a statistically significant difference according to the Friedman test.
Figure 2Two-dimensional and 3-dimensional micro-computed tomography scans of each stage of the endodontic retreatment protocols. Manual (A-C), Reciproc Blue (D-F), WaveOne Gold (G-I), and X1 Blue (J-L) groups after root canal filling (A, D, G, J), filling removal (B, E, H, K) and repreparation (C, F, I, L) stages.
Median, minimum, and maximum values of filling material volume (mm3) after using auxiliary protocols with XP Clean and Flatsonic regardless of the instrument used for repreparation
| Variables | XP Clean | Flatsonic | ||
|---|---|---|---|---|
| Before | After | Before | After | |
| Median | 0.74A* | 0.59B | 0.96A | 0.78B |
| Minimum | 0.31 | 0.27 | 0.01 | 0.00 |
| Maximum | 2.90 | 2.23 | 4.79 | 3.58 |
Different uppercase letters indicate statistically significant differences according to the Wilcoxon test for comparisons of dependent samples and according to the Mann-Whitney test for independent samples.
Figure 3Two-dimensional and 3-dimensional micro-computed tomography scans of the 2 final irrigant activation protocols (before and after). XP Clean (A, B) and Flatsonic (C, D) groups after repreparation (A, C) and after final irrigant activation protocols (B, D).