Literature DB >> 27215810

Removal of Root Canal Fillings in Curved Canals Using Either Reciprocating Single- or Rotary Multi-instrument Systems and a Supplementary Step with the XP-Endo Finisher.

Flávio R F Alves1, Marília F Marceliano-Alves2, Júlio Cézar N Sousa3, Stephanie B Silveira2, José C Provenzano2, José F Siqueira2.   

Abstract

INTRODUCTION: This study compared the efficacy of a reciprocating single-instrument system and a rotary multi-instrument system followed by a supplementary approach with a finishing instrument in removing the filling material from curved canals during retreatment.
METHODS: Forty mesial canals from extracted mandibular molars were instrumented and filled. Then, each mesial canal was retreated by using either Reciproc (VDW, Munich, Germany) or Mtwo (VDW) instruments, alternating the technique used per canal from root to root. The working time was recorded, and the percentage of removed filling volume was assessed by means of micro-computed tomography imaging before and after retreatment. Canals still showing filling material remnants were subjected to an adjunctive approach with the XP-Endo Finisher (FKG Dentaire, La Chaux-de-Fonds, Switzerland), and another microCT scan was taken. Data were statistically analyzed with a significance level of 5%.
RESULTS: The percentage of filling material removed with Mtwo instruments (96%) was significantly higher than Reciproc (89%) (P < .05), both used up to a final instrument size of 40. Mtwo required less time to remove the filling material than Reciproc (P < .05). Intragroup analysis in the Reciproc group showed that the R40 instrument removed significantly more filling material than R25 (P < .05). The supplementary approach with the XP-Endo Finisher was effective in significantly enhancing the removal of filling material (P < .05).
CONCLUSIONS: The rotary multiple-instrument system was more effective and faster than the reciprocating single-instrument approach in removing previous root canal fillings. As for the Reciproc group, it was observed that the larger instrument promoted significantly better results. The adjunctive finishing instrument XP-Endo Finisher significantly improved filling material removal.
Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Keywords:  Endodontic retreatment; reciprocating single-file system; root canal preparation; rotary instruments

Mesh:

Substances:

Year:  2016        PMID: 27215810     DOI: 10.1016/j.joen.2016.04.007

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  30 in total

1.  Reciproc and Reciproc Blue in the removal of bioceramic and resin-based sealers in retreatment procedures.

Authors:  Kaline Romeiro; Andressa de Almeida; Marcely Cassimiro; Luciana Gominho; Eugênia Dantas; Nayane Chagas; Christianne Velozo; Laila Freire; Diana Albuquerque
Journal:  Clin Oral Investig       Date:  2019-05-18       Impact factor: 3.573

2.  Retreatability of three calcium silicate-containing sealers and one epoxy resin-based root canal sealer with four different root canal instruments.

Authors:  David Donnermeyer; Clarissa Bunne; Edgar Schäfer; Till Dammaschke
Journal:  Clin Oral Investig       Date:  2017-06-22       Impact factor: 3.573

3.  Apical extrusion of debris during the preparation of oval root canals: a comparative study between a full-sequence SAF system and a rotary file system supplemented by XP-endo finisher file.

Authors:  Anda Kfir; Rotem Moza-Levi; Moran Herteanu; Amir Weissman; Ronald Wigler
Journal:  Clin Oral Investig       Date:  2017-06-12       Impact factor: 3.573

4.  [In vitro evaluation of the effectiveness of XP-endo Finisher file on smear layer removal after root canal instrumentation].

Authors:  Yue Xin; Jian Yang; Kuang-Yu Song
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2019-02-01

5.  Adjunctive procedure with solvent mixtures in non-surgical endodontic retreatment: does it affect root dentin hardness?

Authors:  Inês Ferreira; Ana Cristina Braga; Maria Ascensão Lopes; Irene Pina-Vaz
Journal:  Odontology       Date:  2021-04-02       Impact factor: 2.634

6.  The effectiveness of the supplementary use of the XP-endo Finisher on bacteria content reduction: a systematic review and meta-analysis.

Authors:  Ludmila Smith de Jesus Oliveira; Rafaella Mariana Fontes de Bragança; Rafael Sarkis-Onofre; André Luis Faria-E-Silva
Journal:  Restor Dent Endod       Date:  2021-06-18

7.  Cleaning Efficiency of XP Finisher, XP Finisher R and Passive Ultrasonic Irrigation Following Retreatment of Teeth Obturated with TotalFill HiFlow Bioceramic Sealer.

Authors:  Reham Hassan; Sherief Elzahar
Journal:  Eur Endod J       Date:  2022-06

8.  Apical transportation using Mtwo or Reciproc retreatment systems in severely curved canals: a micro-computed tomographic study.

Authors:  Isabelle L L Gomes; Flávio R F Alves; Marília F Marceliano-Alves; Stephanie B Silveira; Júlio Cézar N Sousa; José Claudio Provenzano; Lucio Souza Gonçalves
Journal:  Clin Oral Investig       Date:  2022-10-20       Impact factor: 3.606

9.  Effectiveness of XP-Endo Finisher and passive ultrasonic irrigation on intracanal medicament removal from root canals: a systematic review and meta-analysis.

Authors:  Jiani Zhou; Tingjun Liu; Lihong Guo
Journal:  BMC Oral Health       Date:  2021-06-09       Impact factor: 2.757

10.  Safety and Effectiveness of Additional Apical Preparation using a Rotary Heat-treated Nickel-Titanium file with Larger Diameter and Minimum Taper in Retreatment of Curved Root Canals.

Authors:  Jader Camilo Pinto; Fernanda Ferrari Esteves Torres; Airton Oliveira Santos-Junior; Marco Antonio Hungaro Duarte; Juliane Maria Guerreiro-Tanomaru; Mario Tanomaru-Filho
Journal:  Eur J Dent       Date:  2021-02-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.