Literature DB >> 19467053

Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals.

H C Kim1, H J Kim, C J Lee, B M Kim, J K Park, A Versluis.   

Abstract

AIM: To evaluate how different cross-sectional designs affect stress distribution in nickel-titanium (NiTi) instruments during bending, torsion and simulated shaping of a curved canal.
METHODOLOGY: Four NiTi rotary instruments with different cross-sectional geometries were selected: ProFile and HeroShaper systems with a common triangle-based cross section, Mtwo with an S-shaped rectangle-based design and NRT with a modified rectangle-based design. The geometries of the selected files were scanned in a micro-CT and three-dimensional finite-element models were created for each system. Stiffness characteristics for each file system were determined in a series of bending and torsional conditions. Canal shaping was simulated by inserting models of the rotating file into a 45 degrees curved canal model. Stress distribution in the instruments was recorded during simulated shaping. After the instruments were retracted from the canal, residual stresses and permanent bending of their tips due to plastic deformation were determined.
RESULTS: The greatest bending and torsional stiffness occurred in the NRT file. During simulated shaping, the instruments with triangle-based cross-sectional geometry had more even stress distributions along their length and had lower stress concentrations than the instruments with rectangle-based cross sections. Higher residual stresses and plastic deformations were found in the Mtwo and NRT with rectangle-based cross-sectional geometries.
CONCLUSIONS: Nickel-titanium instruments with rectangle-based cross-sectional designs created higher stress differentials during simulated canal shaping and may encounter higher residual stress and plastic deformation than instruments with triangle-based cross sections.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19467053     DOI: 10.1111/j.1365-2591.2009.01553.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  30 in total

1.  Screw-in forces during instrumentation by various file systems.

Authors:  Jung-Hong Ha; Sang Won Kwak; Sung-Kyo Kim; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2016-11-08

2.  Cyclic fatigue resistance of four nickel-titanium rotary instruments: a comparative study.

Authors:  Eugenio Pedullà; Gianluca Plotino; Nicola Maria Grande; Alfio Pappalardo; Ernesto Rapisarda
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

3.  Comparison of the cleaning capacity of Mtwo and Pro Taper rotary systems and manual instruments in primary teeth.

Authors:  Mohammad Reza Azar; Laya Safi; Afshin Nikaein
Journal:  Dent Res J (Isfahan)       Date:  2012-03

4.  Effect of Different Instrumentation Techniques on Vertical Root Fracture Resistance of Endodontically Treated Teeth.

Authors:  Saeid Tavanafar; Azadeh Karimpour; Hamideh Karimpour; Abdulrahman Mohammed Saleh; Musab Hamed Saeed
Journal:  J Dent (Shiraz)       Date:  2015-03

5.  Comparing the Fracture Rate of Hero 642, FlexMaster and Mtwo in the Simulated Canals.

Authors:  Hosein Labaf; Roza Haghgoo; Kiumars Nazarimoghadam; Mahshid Mohamadibasir
Journal:  Iran Endod J       Date:  2014-03-08

6.  Cyclic fatigue resistance tests of Nickel-Titanium rotary files using simulated canal and weight loading conditions.

Authors:  Ok-In Cho; Antheunis Versluis; Gary Sp Cheung; Jung-Hong Ha; Bock Hur; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2013-02-26

7.  Study on bending behaviour of nickel-titanium rotary endodontic instruments by analytical and numerical analyses.

Authors:  C C Tsao; J U Liou; P H Wen; C C Peng; T S Liu
Journal:  Int Endod J       Date:  2012-11-22       Impact factor: 5.264

8.  A survey of experience-based preference of Nickel-Titanium rotary files and incidence of fracture among general dentists.

Authors:  Woocheol Lee; Minju Song; Euiseong Kim; Hyojin Lee; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2012-11-21

Review 9.  Rotary endodontics in primary teeth - A review.

Authors:  Sageena George; S Anandaraj; Jyoti S Issac; Sheen A John; Anoop Harris
Journal:  Saudi Dent J       Date:  2015-11-22

10.  Structural characterisation and mechanical FE analysis of conventional and M-Wire Ni-Ti alloys used in endodontic rotary instruments.

Authors:  Diogo Montalvão; Francisca Sena Alçada; Francisco Manuel Braz Fernandes; Sancho de Vilaverde-Correia
Journal:  ScientificWorldJournal       Date:  2014-01-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.