Literature DB >> 35186681

Accuracy of optimized Sirius ray-tracing method in intraocular lens power calculation.

Li-Qing Wei1, Ying-Hui Fu2, Wei-Hua Pan1, Li Nie2, Yu Chen1, Gui-Fang Liu3, Zhen-Bin Qian2.   

Abstract

AIM: To evaluate the accuracy and predictability of ray tracing-assisted intraocular lens (IOL) calculation function in Sirius internal software and further improve the accuracy by optimizing the calculation of predicted lens position (PLP).
METHODS: This retrospective study recruited 52 eyes of 49 patients. All of the cases with cataract had undergone phacoemulsification combined with IOL implantation. SRK-T, Haigis formula, and Sirius ray-tracing method were all used for each eye's IOL calculation. The mean absolute value of prediction error (prediction error=predicted refraction-postoperative refraction) was defined as mean absolute prediction error (MAPE) and was determined for each method. Calculation of PLP was optimized by effective lens position (ELP). Optimized PLP was entered to Sirius internal software again to verify whether the method was improved.
RESULTS: Compared with SRK-T and Haigis formulas, less accuracy was shown in Sirius ray-tracing method (P=0.001). The ELP of the IOL moved forward compared to PLP (P<0.001). The MAPE of the ELP-inputted Sirius ray-tracing method was reduced. ELP and PLP were well correlated. Taking ELP as y and PLP given by Sirius soft as x, a linear regression formula y=0.1637x+3.1741 was concluded (R2 =0.1066, P=0.018). It was shown that the optimized Sirius ray-tracing method (optimized PLP entered), compared with SRK-T and Haigis formulas, worked with the same accuracy (P=0.038).
CONCLUSION: The original Sirius ray tracing method is not satisfactory enough. However, in normal eyes, the optimized Sirius ray-tracing method in IOL calculation was as accurate as SRK-T and Haigis formulas. International Journal of Ophthalmology Press.

Entities:  

Keywords:  IOL-Master; Sirius; cataract; predicted IOL position; ray-tracing; refractive error

Year:  2022        PMID: 35186681      PMCID: PMC8818452          DOI: 10.18240/ijo.2022.02.06

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  19 in total

1.  Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry.

Authors:  Petros Aristodemou; Nathaniel E Knox Cartwright; John M Sparrow; Robert L Johnston
Journal:  J Cataract Refract Surg       Date:  2011-01       Impact factor: 3.351

2.  Corneal powers measured with a rotating Scheimpflug camera.

Authors:  Kristian Næser; Giacomo Savini; Jesper Flethøj Bregnhøj
Journal:  Br J Ophthalmol       Date:  2015-12-23       Impact factor: 4.638

Review 3.  Calculation of intraocular lens power: a review.

Authors:  Thomas Olsen
Journal:  Acta Ophthalmol Scand       Date:  2007-04-02

4.  Comparison of ray-tracing method and thin-lens formula in intraocular lens power calculations.

Authors:  Haiying Jin; Tanja Rabsilber; Angela Ehmer; Andreas F Borkenstein; Il-Joo Limberger; Haike Guo; Gerd U Auffarth
Journal:  J Cataract Refract Surg       Date:  2009-04       Impact factor: 3.351

5.  Intraocular lens power calculation using a Placido disk-Scheimpflug tomographer in eyes that had previous myopic corneal excimer laser surgery.

Authors:  Giacomo Savini; Kenneth J Hoffer; Domenico Schiano-Lomoriello; Piero Barboni
Journal:  J Cataract Refract Surg       Date:  2018-07-23       Impact factor: 3.351

6.  Accuracy and predictability of intraocular lens power calculation after laser in situ keratomileusis.

Authors:  H V Gimbel; R Sun
Journal:  J Cataract Refract Surg       Date:  2001-04       Impact factor: 3.351

7.  Intraocular lens power calculation by ray-tracing after myopic excimer laser surgery.

Authors:  Giacomo Savini; Andrea Bedei; Piero Barboni; Pietro Ducoli; Kenneth J Hoffer
Journal:  Am J Ophthalmol       Date:  2013-10-05       Impact factor: 5.258

8.  Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis.

Authors:  W Haigis; B Lege; N Miller; B Schneider
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2000-09       Impact factor: 3.117

9.  Comparison of Simulated Keratometry and Total Refractive Power for Keratoconus According to the Stage of Amsler-Krumeich Classification.

Authors:  Kazutaka Kamiya; Yusuke Kono; Masahide Takahashi; Nobuyuki Shoji
Journal:  Sci Rep       Date:  2018-08-20       Impact factor: 4.379

Review 10.  Intraocular lens correction of presbyopia.

Authors:  Rebecca Sieburth; Ming Chen
Journal:  Taiwan J Ophthalmol       Date:  2019 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.