Literature DB >> 21183100

Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry.

Petros Aristodemou1, Nathaniel E Knox Cartwright, John M Sparrow, Robert L Johnston.   

Abstract

PURPOSE: To assess how intraocular lens (IOL) formula choice affects refractive outcomes after cataract surgery using IOLMaster biometry.
SETTING: Department of Ophthalmology, Gloucestershire Hospitals NHS Foundation Trust, Cheltenham, United Kingdom.
DESIGN: Database study.
METHODS: Hypothetical prediction errors were retrospectively calculated on prospectively collected data from electronic medical records using optimized Hoffer Q, Holladay 1, and SRK/T formulas (Sofport AO and Akreos Fit IOLs) across a range of 0.5 mm or 1.0 mm axial length (AL) subgroups.
RESULTS: In short eyes, the Hoffer Q had the lowest mean absolute error (MAE) for ALs from 20.00 to 20.99 mm. The Hoffer Q and Holladay 1 had a lower MAE than the SRK/T for ALs from 21.00 to 21.49 mm. There were no statistically significant differences in MAE for ALs from 21.50 to 21.99 mm. In medium eyes, there were no statistically significant differences in MAE for any IOL formula for ALs from 22.00 to 23.49 mm. For ALs from 23.50 to 25.99 mm, there was a trend toward lower MAEs for the Holladay 1, with statistically significant differences in 2 subgroups. In long eyes, the SRK/T had the lowest MAE, with statistically significant differences for ALs of 27.00 mm or longer.
CONCLUSIONS: The Hoffer Q performed best for ALs from 20.00 to 20.99 mm, the Hoffer Q and Holladay 1 for ALs from 21.00 to 21.49 mm, and the SRK/T for ALs of 27.00 mm or longer. Using optimized constants, refractive outcomes of 40%, 75%, and 95% within ±0.25 diopter (D), ±0.50 D, and ±1.00 D, respectively, were achievable. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned. Additional disclosure is found in the footnotes.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21183100     DOI: 10.1016/j.jcrs.2010.07.032

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  63 in total

1.  Comparison of the biometric formulas used for applanation A-scan ultrasound biometry.

Authors:  Fatih Özcura; Serdar Aktaş; Hacı Murat Sağdık; Mehmet Tetikoğlu
Journal:  Int Ophthalmol       Date:  2016-02-08       Impact factor: 2.031

2.  Refractive outcome of combined phacoemulsification and endoscopic cyclophotocoagulation.

Authors:  S Kang; S Luk; H Han; M F Cordeiro; F Ahmed; P Bloom; L Crawley
Journal:  Int Ophthalmol       Date:  2016-12-19       Impact factor: 2.031

3.  Predictability of intraocular lens power calculation formulae in infantile eyes with unilateral congenital cataract: results from the Infant Aphakia Treatment Study.

Authors:  Deborah K Vanderveen; Rupal H Trivedi; Azhar Nizam; Michael J Lynn; Scott R Lambert
Journal:  Am J Ophthalmol       Date:  2013-09-04       Impact factor: 5.258

4.  Keratometry with five different techniques: a study of device repeatability and inter-device agreement.

Authors:  Shiva Mehravaran; Soheila Asgari; Sara Bigdeli; Ashkan Shahnazi; Hassan Hashemi
Journal:  Int Ophthalmol       Date:  2014-02-23       Impact factor: 2.031

5.  Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation.

Authors:  Ahmet Kirgiz; Kurşat Atalay; Havva Kaldirim; Kubra Serefoglu Cabuk; Mehmet Orcun Akdemir; Muhittin Taskapili
Journal:  Int Ophthalmol       Date:  2016-09-01       Impact factor: 2.031

6.  [Comparison of two optical biometric devices for intraocular lens calculation].

Authors:  M-S Uckmann; M Stattin; C Zehetner; S Neururer; L Speicher
Journal:  Ophthalmologe       Date:  2019-03       Impact factor: 1.059

7.  Refractive Outcomes for Cataract Surgery With Toric Intraocular Lenses at a Veterans Affairs Medical Center.

Authors:  Elaine M Tran; Kevin S Tang; Allison J Chen; Michael L Chen; David R Rivera; Jorge J Rivera; Paul B Greenberg
Journal:  Fed Pract       Date:  2020-03

8.  Clinical application of bicylindric intraocular lens power calculation method.

Authors:  Jorge A Calvo-Sanz; Cristina Bonnin-Arias; Alfonso Arias-Puente
Journal:  Indian J Ophthalmol       Date:  2020-06       Impact factor: 1.848

9.  Accuracy of axial length measurements from immersion B-scan ultrasonography in highly myopic eyes.

Authors:  Qing-Hua Yang; Bing Chen; Guang-Hua Peng; Zhao-Hui Li; Yi-Fei Huang
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

10.  Agreement of IOL power and axial length obtained by IOLMaster 500 vs IOLMaster 500 with Sonolink connection.

Authors:  Sabong Srivannaboon; Chareenun Chirapapaisan; Patchara Nantasri; Mathinee Chongchareon; Pratuangsri Chonpimai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-01-12       Impact factor: 3.117

View more