Literature DB >> 19304085

Comparison of ray-tracing method and thin-lens formula in intraocular lens power calculations.

Haiying Jin1, Tanja Rabsilber, Angela Ehmer, Andreas F Borkenstein, Il-Joo Limberger, Haike Guo, Gerd U Auffarth.   

Abstract

PURPOSE: To compare the accuracy of the thin-lens and ray-tracing methods in intraocular lens (IOL) power calculations in normal eyes and eyes after corneal refractive surgery.
SETTING: International Vision Correction Research Centre, University of Heidelberg, Heidelberg, Germany.
METHODS: Pseudophakic eye models were constructed using Zemax optical software, importing corneal radii (normal ray tracing) and corneal surface elevation data (individual ray tracing) measured by Pentacam Scheimpflug photography. Algorithms to predict IOL position (effective lens position [ELP]) or postoperative anterior chamber depth [ACD(post)]) (Haigis, Hoffer Q, Norrby, Olsen 2) were used in the thin-lens and ray-tracing methods. Intraocular lens power was calculated in 25 eyes after corneal refractive surgery using normal and double-K modified thin-lens and ray-tracing methods.
RESULTS: Back-calculation of ELP and ACD(post) were well correlated. Using algorithms of Haigis, Hoffer Q, Norrby, and Olsen 2 to predict IOL position, mean absolute prediction errors (MAEs) of the thin-lens formula were 0.64 diopters (D) +/- 0.52 (SD), 0.57 +/- 0.46 D, 0.59 +/- 0.42 D, and 0.61 +/- 0.47 D, respectively; MAEs of normal ray-tracing method were 0.64 +/- 0.50 D, 0.58 +/- 0.44 D, 0.59 +/- 0.41 D, and 0.62 +/- 0.45 D, respectively; MAEs of individual ray-tracing method were 0.66 +/- 0.52 D, 0.59 +/- 0.45 D, 0.59 +/- 0.43 D, and 0.62 +/- 0.50 D, respectively. No statistical differences were found between the thin-lens and ray-tracing methods.
CONCLUSION: Theoretical thin-lens formulas were as accurate as the ray-tracing method in IOL power calculations in normal eyes and eyes after refractive surgery.

Mesh:

Year:  2009        PMID: 19304085     DOI: 10.1016/j.jcrs.2008.12.015

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  15 in total

1.  Challenges and approaches in modern biometry and IOL calculation.

Authors:  Wolfgang Haigis
Journal:  Saudi J Ophthalmol       Date:  2012-01

Review 2.  Clinically relevant biometry.

Authors:  Afsun Sahin; Pedram Hamrah
Journal:  Curr Opin Ophthalmol       Date:  2012-01       Impact factor: 3.761

3.  Accuracy of optimized Sirius ray-tracing method in intraocular lens power calculation.

Authors:  Li-Qing Wei; Ying-Hui Fu; Wei-Hua Pan; Li Nie; Yu Chen; Gui-Fang Liu; Zhen-Bin Qian
Journal:  Int J Ophthalmol       Date:  2022-02-18       Impact factor: 1.779

4.  Three-dimensional topographic changes of anterior chamber depth following phacoemulsification with intraocular lens implantation in cataract patients.

Authors:  Yuexin Wang; Siman Sun; Shanshan Wei; Yining Guo; Tingyi Wu; Xuemin Li
Journal:  Int Ophthalmol       Date:  2022-01-05       Impact factor: 2.031

5.  Accuracy of axial length measurements from immersion B-scan ultrasonography in highly myopic eyes.

Authors:  Qing-Hua Yang; Bing Chen; Guang-Hua Peng; Zhao-Hui Li; Yi-Fei Huang
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

6.  Refractive changes after removal of anterior IOLs in temporary piggyback IOL implantation for congenital cataracts.

Authors:  Dong Hui Lim; Sung-Ho Choi; Tae-Young Chung; Eui-Sang Chung
Journal:  Korean J Ophthalmol       Date:  2013-02-27

7.  Personalized pseudophakic model for refractive assessment.

Authors:  Filomena J Ribeiro; António Castanheira-Dinis; João M Dias
Journal:  PLoS One       Date:  2012-10-03       Impact factor: 3.240

8.  Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation.

Authors:  Mohammad Ghoreyshi; Ahmadreza Khalilian; Mohammadreza Peyman; Mohaddeseh Mohammadinia; Alireza Peyman
Journal:  J Curr Ophthalmol       Date:  2017-10-27

Review 9.  Update on Intraocular Lens Formulas and Calculations.

Authors:  Tina Xia; Christine E Martinez; Linda M Tsai
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2020 May-Jun

Review 10.  Intraocular lens power calculation in eyes with previous corneal refractive surgery.

Authors:  Giacomo Savini; Kenneth J Hoffer
Journal:  Eye Vis (Lond)       Date:  2018-07-08
View more