| Literature DB >> 35144583 |
E Elgueta-Cancino1, K Rice1, D Abichandani2, D Falla3.
Abstract
BACKGROUND: Smartphone applications offer an accessible and practical option to measure neck range of motion (ROM) and are becoming more commonly used in clinical practice. We assessed the validity, reliability, and responsiveness of smartphone applications (apps) to measure neck ROM in people with and without neck pain.Entities:
Keywords: Cervical spine; Movement; Neck pain; Range of motion; Reliability; Validity
Mesh:
Year: 2022 PMID: 35144583 PMCID: PMC8832814 DOI: 10.1186/s12891-022-05066-6
Source DB: PubMed Journal: BMC Musculoskelet Disord ISSN: 1471-2474 Impact factor: 2.362
Fig. 1A PRISMA flow diagram
Study characteristics
| Study | Country | Study design | Sample size | Participant characteristics | Cause of neck pain and pain characteristics | ROM tested | Smart app details |
|---|---|---|---|---|---|---|---|
| Pourahmadi et al., 2018 [ | Iran | Cross sectional study | 40 | Age: 31.12 (6.38) Gender: 20 /20 | Non-specific, non-traumatic neck pain Pain Intensity VAS - 3.71 ± 1.06 | Neck flexion, extension, lateral flexion, and rotation | ‘Goniometer Pro[G-pro]’ app (version 2.7). It works like a digital gravity-based inclinometer- iPhone 7 uses built-in accelerometer |
| Palsson et al., 2019 [ | Denmark | Cross sectional study | 30 | Age: 2[(21-37] Gender: 19/11 | Asymptomatic NA | Neck flexion, extension, and rotation | ‘Balacy’ app (beta version, MEDEI, Aalborg, Denmark) custom made application |
| Stenneberg et al., 2018 [ | Netherlands | Cross sectional and repeated measures design | 30 for validity study, 26 for reliability study | Age: - Validity study: 53.4. Reliability study: 45.2 Gender: - Validity Study: 11/19 Reliability study: 7/19 | NR NDI (median, range): Validity stud y- 9.5 (1–26) Reliability study- 11.4 (3–27) Pain duration:> 1 week | Neck flexion, extension, lateral flexion, and rotation. | ‘3D range of motion’ custom made application - iPhone 4 s uses built-in gyroscope and accelerometer |
| Guidetti et al., 2017 [ | Italy | Descriptive correlational study | 23 | Age: 26 (5) Gender:13/10 | Asymptomatic NA | Neck flexion, extension, lateral flexion, and rotation. | ‘Compass’ app - iPhone 5c uses built-in accelerometer, gyroscope and magnetometer |
| Ullucci et al., 2019 [ | USA | NR | 38 | Age: 23.8 (1.2) Gender: 19/19 | Asymptomatic NA | Upper cervical spine rotation | ‘Clinometer’ app- Android and iPhone |
| Ghorbani et al., 2020 [ | Iran | NR | 20 | Age: 25.9 [9-33] Gender: 7/13 | NR Pain duration: > 4 weeks | Neck flexion, extension, lateral flexion and rotation. | ‘Clinometer’ app - iPhone 6 s uses built-in gyroscope and accelerometer |
| Chang et al., 2019 [ | Taiwan | Two stage repeated measures design | 41 | Age: 36.9 (7.6) Gender: 9/32 | Asymptomatic NA | Neck flexion, extension, lateral flexion, and rotation. | ‘GPS status & Toolbox app’ - iPhone uses built-in gyroscope and magnetometer |
| Satpute et al., 2019 [ | India | Repeated measures reliability design | 32 | Age: 40.53 Gender: 17/15 | Asymptomatic NA | Upper cervical spine rotation with FRT, and with C0-C2 test | ‘Compass’ app- iPhone 6 uses built-in gyroscope, magnetometer and accelerometer |
| Quek et al., 2014 [ | Australia | NR | 21 | Age: 31 (9.1) Gender: 11/20 | Asymptomatic NA | Neck flexion, extension, lateral flexion, and rotation | Custom made app- Android phone (Samsung Galaxy S3) uses built-in accelerometer and gyroscope |
| Monreal et al., 2021 [ | USA | Repeated measure, correlational design | 50 | Age: 21.46 (2.78) Gender: 15/35 | Asymptomatic NA | Neck flexion, extension, lateral flexion and rotation | ‘Clinometer’ app - Smartphone |
| Rodríguez-Sanza et al., 2019 [ | Spain | Cross sectional study | Validity study: 25 Reliability study: 10 | Age: - Validity study: 25 (6.72) [18-53] Reliability study: NR Gender: - Validity study: 11/14 Reliability: NR | NR Duration of neck pain: Mean (SD) (months) Validity study: 70.48 (67.25) | Upper cervical spine: flexion and extension Lower cervical spine: flexion, extension, lateral flexion and rotation | ‘Clinometer’ app- Xiaomi A1 uses built-in accelerometers and a gyroscope. ‘Compass’ app-Xiaomi A1 uses built-in accelerometer. |
| Tousignant-Laflamme et al., 2013 [ | Canada | Descriptive correlational design | 28 | Age: 23 (6) [19-43] Gender: 9/19 | Asymptomatic NA | Neck flexion, extension, lateral flexion, and rotation | ‘Clinometer’ app (Peter Breitling, Version 3.3)- iPhone uses built-in accelerometers ‘Compass’ app- iPhone uses built-in magnetometer. |
SD standard deviation, M male, F female, VAS visual analogue scale, NDI neck disability index, NR not reported, NA non applicable, FRT flexion-rotation test
Summary of characteristics of the measurement properties
| Outcome measure/ measurement property | ||||||
|---|---|---|---|---|---|---|
| Study | Reliability (Intra rater) | Reliability (Inter rater) | Measurement Error | Criterion Validity | Construct Validity | Responsiveness |
| Asymptomatic | Clinometer app. – Available free of payment in apple and google play app stores. | |||||
| Ullucci et al., 2019 [ | ✔ | ✔ | ||||
| Tousignant-Laflamme et al., 2013 [ | ✔ | ✔ | ✔ | |||
| Monreal et al., 2021 [ | ✔ | ✔ | ✔ | |||
| Neck pain | Goniometer – Available free of charge in apple and google play app stores. | |||||
| Pourahmadi et al., 2018 [ | ✔ | ✔ | ||||
| Ghorbani et al., 2020 [ | ✔ | ✔ | ✔ | ✔ | ||
| Rodríguez-Sanza et al., 2019 [ | ✔ | ✔ | ✔ | |||
| Asymptomatic | Compass app. – Available free of charge in apple and google play app stores. | |||||
| Guidetti et al., 2017 [ | ✔ | ✔ | ✔ | ✔ | ||
| Satpute et al., 2019 [ | ✔ | ✔ | ✔ | ✔ | ||
| Tousignant-Laflamme et al., 2013 [ | ✔ | ✔ | ✔ | |||
| Neck pain | Compass app. – Available free of charge in apple and google play app stores | |||||
| Rodríguez-Sanza et al., 2019 [ | ✔ | ✔ | ✔ | |||
| Asymptomatic | Other apps (custom made). – Non-available in app stores. | |||||
| Chang et al., 2019a [ | ✔ | ✔ | ✔ | ✔ | ||
| Quek et al., 2014 [ | ✔ | ✔ | ✔ | |||
| Palsson et al., 2019 [ | ✔ | |||||
| Neck pain | Other apps (custom made). – Non-available in app stores. | |||||
| Stenneberg et al., 2018 [ | ✔ | ✔ | ✔ | ✔ | ||
aGPS status & Toolbox app. – Available in apple (payment required) and google play (free of charge) app stores
Summary of the GRADE assessment
| Outcome measure/ measurement property | Studies | Sample Size | ROB | Criteria for good Measurement Properties | ROB overall rating | GRADE - quality of evidence | |||
|---|---|---|---|---|---|---|---|---|---|
| Inconsistency | Impreciseness | Indirectness | Overall Quality of Evidence | ||||||
| Reliability (Intra rater) | Ullucci P.A. et al., 2019 [ | 38 | D | (+) | ↓ | No | No | No | Moderate |
| Tousignant-Laflamme et al. 2013 [ | 28 | A | (−) | ||||||
| Monreal C. et al., 2021 [ | 50 | A | (+) | ||||||
| Reliability (Inter rater) | Ullucci P.A. et al., 2019 [ | 38 | D | (+) | ↓ | ↓ | ↓ | No | Very Low |
| Tousignant-Laflamme et al. 2013 [ | 28 | A | (−) | ||||||
| Measurement Error | Monreal C. et al., 2021 [ | 50 | A | (?) | Serious | Inconsistent | Not rated | ||
| Criterion Validity | Tousignant-Laflamme et al. 2013 [ | 28 | A | (−) | Serious | Inconsistent | Not rated | ||
| (Concurrent) | Monreal C. et al., 2021 [ | 50 | D | (?) | |||||
| Reliability (Intra-rater) | Pourahmadi M.R. et al., 2018 [ | 40 | A | (−) | No | ↓ | ↓ | No | Low |
| Ghorbani F. et al., 2020 [ | 20 | A | (−) | ||||||
| Rodríguez-Sanza J. et al., 2019 [ | 10 | A | (+) | ||||||
| Reliability (Inter-rater) | Pourahmadi M.R. et al., 2018 [ | 40 | A | (−) | No | ↓ | No | Low | |
| Ghorbani F. et al., 2020 [ | 20 | A | (−) | ||||||
| Rodríguez-Sanza J. et al., 2019 [ | 10 | A | (+) | ||||||
| Measurement Error | Ghorbani F. et al., 2020 [ | 20 | A | (?) | No | Inconsistent | Not rated | ||
| Criterion | Ghorbani F. et al., 2020 [ | 20 | A | (−) | ↓ | ↓ | ↓ | No | Very Low |
| Rodríguez-Sanza J. et al., 2019 [ | 25 | I | (?) | Very serious | Inconsistent | No | Not rated | ||
| Reliability (Intra rater) | Guidetti. et al., 2017 [ | 23 | A | (+) | ↓ | No | ↓ | No | Low |
| Satpute K. et al., 2019 [ | 32 | D | (+) | ||||||
| Tousignant-Laflamme et al. 2013 [ | 28 | A | (−) | ||||||
| Reliability (Inter rater) | Guidetti L. et al., 2017 [ | 23 | A | (+) | ↓ | No | ↓ | No | Low |
| Satpute K. et al., 2019 [ | 32 | D | (+) | ||||||
| Tousignant-Laflamme et al. 2013 [ | 28 | A | (−) | ||||||
| Measurement Error | Guidetti L. et al., 2017 [ | 23 | A | (?) | Serious | Inconsistent | Not rated | ||
| Satpute K. et al., 2019 [ | 32 | D | (?) | ||||||
| Criterion Validity | Guidetti L. et al., 2017 [ | 23 | A | (+) | No | Inconsistent | Not rated | ||
| Tousignant-Laflamme et al. 2013 [ | 28 | A | (−) | ||||||
| Construct Validity (convergent) | Satpute K. et al., 2019 [ | 32 | A | (?) | Serious | Inconsistent | Not rated | ||
| Reliability (Intra rater) | Rodríguez-Sanza J. et al., 2019 [ | 10 | A | (+) | ↓ | No | ↓↓ | No | Very Low |
| Reliability (Inter rater) | Rodríguez-Sanza J. et al., 2019 [ | 10 | A | (+) | ↓ | No | ↓↓ | No | Very Low |
| Criterion Validity | Rodríguez-Sanza J. et al., 2019 [ | 25 | I | (?) | Serious | Inconsistent | Not rated | ||
| Reliability (Intra rater) | Chang K. et al., 2019 [ | 41 | D | (+) | ↓↓ | No | ↓↓ | No | Very Low |
| Quek J. et al., 2014 [ | 21 | D | (+) | ↓ ↓ | No | ↓↓ | Very Low | ||
| Reliability (Inter rater) | Chang K. et al., 2019 [ | 41 | D | (+) | ↓ ↓ | No | ↓↓ | No | Very Low |
| Measurement Error | Chang K. et al., 2019 [ | 41 | D | (?) | Very serious | Inconsistent | Not rated | ||
| Quek J. et al., 2014 [ | 21 | D | (?) | Very serious | Inconsistent | Not rated | |||
| Criterion Validity | Palsson T. et al., 2019 [ | 30 | A | (+) | ↓ | No | ↓↓ | No | Very Low |
| Criterion Validity | Quek J. et al., 2014 [ | 21 | A | (+) | ↓ | No | ↓↓ | No | Very Low |
| Construct Validity (convergent) | Chang K. et al., 2019 [ | 41 | V | (+) | No | No | ↓↓ | No | Low |
| Reliability (Intra rater) | Stenneberg M.S. et al., 2018 [ | 26 | A | (+) | ↓ | No | ↓↓ | No | Very Low |
| Reliability (Inter rater) | Stenneberg M.S. et al., 2018 [ | 26 | A | (+) | ↓ | No | ↓↓ | No | Very Low |
| Measurement Error | Stenneberg M.S. et al., 2018 [ | 26 | A | (?) | Serious | Inconsistent | Not rated | ||
| Criterion Validity | Stenneberg M.S. et al., 2018 [ | 26 | A | (+) | ↓ | No | ↓↓ | No | Very Low |
PBOM Performance based outcome measure, ROB Risk of Bias, GRADE Grading of Recommendations, Assessment, Development, and Evaluations, V very good, A adequate, D doubtful, I inadequate, (+) - sufficient, (−) - insufficient, (±) - inconsistent, (?) – indeterminate, ↓ – downgraded one level
Fig. 2Forest plot presenting the pooled correlation coefficients for intra-rater reliability of clinometer apps for the measurement of neck range of motion in asymptomatic people. * ICC – intraclass correlation coefficient, CI – confidence interval
Fig. 3Forest plot presenting the pooled correlation coefficients for intra-rater reliability of clinometer apps for the measurement of neck range of motion in people with neck pain
Fig. 4Forest plot presenting the pooled correlation coefficients for inter-rater reliability of clinometer apps for the measurement of neck range of motion in people with neck pain