Literature DB >> 30040023

Reliability of Smartphone Inclinometry to Measure Upper Cervical Range of Motion.

Paul A Ullucci, Frank Tudini, Matthew F Moran.   

Abstract

CONTEXT: Assessment of upper cervical range of motion (UCROM) and mobility is commonly performed in the clinical setting for patients suffering from headache, neck pain, and vestibular dysfunction. Reliable and reproducible measurement of this motion is often difficult or too expensive to perform in the clinical setting. Smartphone applications using the device's internal gyroscope offer an easy and inexpensive means of measuring UCROM, but their reliability has not been reported in the literature.
OBJECTIVE: To assess the reliability of an inclinometer application installed on 2 different devices (iPhone 6 [IP] and android [AN]) and to measure UCROM in a healthy population.
DESIGN: Two examiners assessed passive UCROM. Each examiner was assigned to a specific smartphone, and a repeated-measures design consisting of 3 trials for each examiner-phone was performed. The order of testing was randomized, and the examiners were blinded to UCROM measures.
SETTING: Laboratory. PARTICIPANTS: A total of 38 subjects (19 females and 19 males; age: 23.8 [1.2] y) without pain or injury to the neck or spine for at least 3 months. INTERVENTION: Each examiner passively flexed the head fully, rotated the head fully in 1 direction, and then in another. Peak rotation measures were recorded from each smartphone. Three trials were performed for each phone, with a 2-minute break between examiners/phones. MAIN OUTCOME MEASURES: Intraclass correlation coefficient using a 2-way mixed, absolute agreement model was obtained (1) between each examiner-phone and (2) within each examiner-phone for the measurements in each rotation direction.
RESULTS: Interphone/examiner reliability comparing average peak and total UCROM for each device was excellent (.87, .81). Intraphone/examiner reliability, determined across 3 trials, was also excellent (AN right rot. = .91, AN left rot. = .96; IP right rot. = .98, IP left rot. = .95).
CONCLUSION: UCROM can be reliably measured using a smartphone inclinometer application.

Entities:  

Keywords:  atlanto-axial joint; atlanto-occipital joint; inclinometer; upper cervical spine

Year:  2019        PMID: 30040023     DOI: 10.1123/jsr.2018-0048

Source DB:  PubMed          Journal:  J Sport Rehabil        ISSN: 1056-6716            Impact factor:   1.931


  5 in total

1.  Osteopathic Cranial Manipulation for a Patient With Whiplash-Associated Disorder: A Case Report.

Authors:  Giovanni Parravicini; Matteo Ghiringhelli
Journal:  J Chiropr Med       Date:  2022-04-06

2.  Interexaminer Reliability and Validity of Quantity of Cervical Mobility during Online Dynamic Inspection.

Authors:  Leire Leonet-Tijero; Jaime Corral-de-Toro; Jacobo Rodríguez-Sanz; Mar Hernández-Secorún; Hugo Abenia-Benedí; María Orosia Lucha-López; Sofía Monti-Ballano; Julián Müller-Thyssen-Uriarte; Héctor Tricás-Vidal; César Hidalgo-García; José Miguel Tricás-Moreno
Journal:  Diagnostics (Basel)       Date:  2022-02-21

3.  Reliability and validity of clinically accessible smartphone applications to measure joint range of motion: A systematic review.

Authors:  Justin W L Keogh; Alistair Cox; Sarah Anderson; Bernard Liew; Alicia Olsen; Ben Schram; James Furness
Journal:  PLoS One       Date:  2019-05-08       Impact factor: 3.240

4.  Smartphone Application with Virtual Reality Goggles for the Reliable and Valid Measurement of Active Craniocervical Range of Motion.

Authors:  Ke-Vin Chang; Wei-Ting Wu; Mei-Chu Chen; Yi-Chi Chiu; Der-Sheng Han; Chih-Cheng Chen
Journal:  Diagnostics (Basel)       Date:  2019-07-10

5.  Measurement properties of smartphone applications for the measurement of neck range of motion: a systematic review and meta analyses.

Authors:  E Elgueta-Cancino; K Rice; D Abichandani; D Falla
Journal:  BMC Musculoskelet Disord       Date:  2022-02-10       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.