Literature DB >> 3488378

Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters.

M A King, R B Schwinger, B C Penney, P W Doherty, J A Bianco.   

Abstract

A number of radiopharmaceuticals of great current clinical interest for imaging are labeled with radionuclides that emit medium- to high-energy photons either as their primary radiation, or in low abundance in addition to their primary radiation. The imaging characteristics of these radionuclides result in gamma camera image quality that is inferior to that of 99mTc images. Thus, in this investigation 111In and 123I contaminated with approximately 4% 124I were chosen to test the hypothesis that a dramatic improvement in planar and SPECT images may be obtainable with digital image restoration. The count-dependent Metz filter is shown to be able to deconvolve the rapid drop at low spatial frequencies in the imaging system modulation transfer function (MTF) resulting from the acceptance of septal penetration and scatter in the camera window. Use of the Metz filter was found to result in improved spatial resolution as measured by both the full width at half maximum and full width at tenth maximum for both planar and SPECT studies. Two-dimensional, prereconstruction filtering with optimized Metz filters was also determined to improve image contrast, while decreasing the noise level for SPECT studies. A dramatic improvement in image quality was observed with the clinical application of this filter to SPECT imaging.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3488378

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  9 in total

1.  Improved positron emission tomography quantification by Fourier-based restoration filtering.

Authors:  J M Links; J P Leal; H W Mueller-Gaertner; H N Wagner
Journal:  Eur J Nucl Med       Date:  1992

2.  Stimulating technetium-99m cerebral perfusion studies with a three-dimensional Hoffmann brain phantom: collimator and filter selection in SPECT neuroimaging.

Authors:  H J Kim; J S Karp; P D Mozley; S O Yang; D H Moon; H F Kung; H K Lee; A Alavi
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

Review 3.  Understanding Fourier space and filter selection.

Authors:  I G Zubal; G Wisniewski
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

4.  Interactive reconstruction in single-photon tomography.

Authors:  T R Miller; J W Wallis; A D Wilson
Journal:  Eur J Nucl Med       Date:  1989

5.  Optimal preprocessing Butterworth-Wiener filter for Tl-201 myocardial SPECT.

Authors:  N Honda; K Machida; J Tsukada; H Kaizu; M Hosoba
Journal:  Eur J Nucl Med       Date:  1987

6.  Optimization of Butterworth filter for brain SPECT imaging.

Authors:  S Minoshima; H Maruno; N Yui; T Togawa; F Kinoshita; M Kubota; K L Berger; Y Uchida; K Uno; N Arimizu
Journal:  Ann Nucl Med       Date:  1993-05       Impact factor: 2.668

7.  Usefulness of brain 99mTc-TRODAT-1 SPET for the evaluation of Parkinson's disease.

Authors:  Wen-Sheng Huang; Meei-Shyuan Lee; Jiann-Chyun Lin; Cheng-Yu Chen; Yu-Wen Yang; Shinn-Zong Lin; Shiaw-Pyng Wey
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

8.  Improving (18)F-Fluoro-D-Glucose-Positron Emission Tomography/Computed Tomography Imaging in Alzheimer's Disease Studies.

Authors:  Karin Knešaurek
Journal:  World J Nucl Med       Date:  2015 Sep-Dec

Review 9.  [18F]Tetrafluoroborate ([18F]TFB) and its analogs for PET imaging of the sodium/iodide symporter.

Authors:  Huailei Jiang; Timothy R DeGrado
Journal:  Theranostics       Date:  2018-06-24       Impact factor: 11.556

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.