Improved positron emission tomography quantification by Fourier-based restoration filtering.

J M Links1, J P Leal, H W Mueller-Gaertner, H N Wagner.   

Abstract

Positron emission tomography (PET) images are characterized by both poor spatial resolution and high statistical noise. Conventional methods to reduce noise, such as local weighted averaging, produce further deteriorations in spatial resolution, while the use of deconvolution to recover resolution typically amplifies noise to unacceptable levels. We studied the use of two-dimensional Fourier filtering to simultaneously increase quantitative recovery and reduce noise. The filter was based on inversion of the scanner's measured transfer function, coupled with high frequency roll-off. In phantom studies, we found improvements in both "hot" and "cold" sphere quantification. Compared with ramp-only filtering, improvements in hot spot recovery for the highest accuracy filter averaged 13.6% +/- 6.6% for spheres larger than 15 mm; improvements in cold spot recovery averaged 30.7% +/- 4.7%. At the same time, the noise was reduced by a factor of 3 compared with randomly filtering. Fourier-based image restoration filtering is thus capable of improving both accuracy and precision in PET.

Mesh:

Substances:

Year:  1992        PMID: 1425779     DOI: 10.1007/bf00175857

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  15 in total

1.  Relative importance of the error sources in Wiener restoration of scintigrams.

Authors:  B C Penney; S J Glick; M A King
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

2.  Performance standards in positron emission tomography.

Authors:  J S Karp; M E Daube-Witherspoon; E J Hoffman; T K Lewellen; J M Links; W H Wong; R D Hichwa; M E Casey; J G Colsher; R E Hitchens
Journal:  J Nucl Med       Date:  1991-12       Impact factor: 10.057

3.  Enhancement of SPECT images by Fourier filtering the projection image set.

Authors:  M T Madsen; C H Park
Journal:  J Nucl Med       Date:  1985-04       Impact factor: 10.057

4.  Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters.

Authors:  M A King; R B Schwinger; B C Penney; P W Doherty; J A Bianco
Journal:  J Nucl Med       Date:  1986-08       Impact factor: 10.057

5.  Determination of the optimum filter function for SPECT imaging.

Authors:  D R Gilland; B M Tsui; W H McCartney; J R Perry; J Berg
Journal:  J Nucl Med       Date:  1988-05       Impact factor: 10.057

6.  Interactive visual optimization of SPECT prereconstruction filtering.

Authors:  M A King; S J Glick; B C Penney; R B Schwinger; P W Doherty
Journal:  J Nucl Med       Date:  1987-07       Impact factor: 10.057

7.  Fast count-dependent digital filtering of nuclear medicine images: concise communication.

Authors:  M A King; P W Doherty; R B Schwinger; D A Jacobs; R E Kidder; T R Miller
Journal:  J Nucl Med       Date:  1983-11       Impact factor: 10.057

8.  Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections.

Authors:  M Bergström; L Eriksson; C Bohm; G Blomqvist; J Litton
Journal:  J Comput Assist Tomogr       Date:  1983-02       Impact factor: 1.826

9.  Quantitative potentials of dynamic emission computed tomography.

Authors:  T F Budinger; S E Derenzo; W L Greenberg; G T Gullberg; R H Huesman
Journal:  J Nucl Med       Date:  1978-03       Impact factor: 10.057

10.  Performance evaluation of a positron tomograph designed for brain imaging.

Authors:  E J Hoffman; M E Phelps; S C Huang
Journal:  J Nucl Med       Date:  1983-03       Impact factor: 10.057

View more
  4 in total

Review 1.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

Review 2.  Multidetector single-photon emission tomography: are two (or three or four) heads really better than one?

Authors:  J M Links
Journal:  Eur J Nucl Med       Date:  1993-05

3.  Quantitative evaluation of a comprehensive motion, resolution, and attenuation correction program: initial experience.

Authors:  P Rigo; P Van Boxem; J Foulon; M Safi; J Engdahl; J Links
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

4.  Dynamic positron emission tomography image restoration via a kinetics-induced bilateral filter.

Authors:  Zhaoying Bian; Jing Huang; Jianhua Ma; Lijun Lu; Shanzhou Niu; Dong Zeng; Qianjin Feng; Wufan Chen
Journal:  PLoS One       Date:  2014-02-27       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.