Literature DB >> 3501758

Optimal preprocessing Butterworth-Wiener filter for Tl-201 myocardial SPECT.

N Honda1, K Machida, J Tsukada, H Kaizu, M Hosoba.   

Abstract

The optimal frequency characteristic of Butterworth-Wiener filters (BWF) for improving the image quality of 201Tl myocardial SPECT was determined by a phantom experiment. Thirty two projection images of the phantom containing 11.1 MBq of 201Tl with 4 different cold lesions were collected during a 180 degree arc of a gamma camera. A set of the projection images were processed with each of 27 different BWFs, and SPECT images were reconstructed by Shepp-Logan filtered backprojection. The SPECT images were evaluated for their diagnostic ability to visibly detect the cold lesions by four nuclear medicine physicians. The lesion contrasts were used as an adjunctive tool to determine the optimum filter. The optimal combination of the parameters determining BWF characteristics (for the data of about 100 count/pixel at the myocardium) is: 1) cutoff of 0.25/pixel, 2) FWHM of 3 pixels, 3) noise/signal ratio of 0.02. FWHM and noise/signal ratio affected lesion contrast much less than cutoff frequency. Clinical myocardial SPECT images processed with the optimal BWF showed less noise and sharper delineation of the myocardium.

Mesh:

Substances:

Year:  1987        PMID: 3501758     DOI: 10.1007/BF00292492

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  4 in total

1.  Enhancement of SPECT images by Fourier filtering the projection image set.

Authors:  M T Madsen; C H Park
Journal:  J Nucl Med       Date:  1985-04       Impact factor: 10.057

2.  Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters.

Authors:  M A King; R B Schwinger; B C Penney; P W Doherty; J A Bianco
Journal:  J Nucl Med       Date:  1986-08       Impact factor: 10.057

3.  Fast count-dependent digital filtering of nuclear medicine images: concise communication.

Authors:  M A King; P W Doherty; R B Schwinger; D A Jacobs; R E Kidder; T R Miller
Journal:  J Nucl Med       Date:  1983-11       Impact factor: 10.057

4.  Two-dimensional filtering of SPECT images using the Metz and Wiener filters.

Authors:  M A King; R B Schwinger; P W Doherty; B C Penney
Journal:  J Nucl Med       Date:  1984-11       Impact factor: 10.057

  4 in total
  4 in total

Review 1.  Quantitative analysis in single photon emission tomography (SPET).

Authors:  K A Blokland; H H Reiber; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1992

2.  Iterative correction method for shift-variant blurring caused by collimator aperture in SPECT.

Authors:  K Ogawa; H Katsu
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

Review 3.  Understanding Fourier space and filter selection.

Authors:  I G Zubal; G Wisniewski
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

4.  Adaptive noise reduction of scintigrams with a wavelet transform.

Authors:  Koichi Ogawa; Masahiko Sakata; Yu Li
Journal:  Int J Biomed Imaging       Date:  2012-02-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.