Literature DB >> 2787746

Interactive reconstruction in single-photon tomography.

T R Miller1, J W Wallis, A D Wilson.   

Abstract

A new method is described to allow interactive selection of the reconstruction filter at the time of interpretation of images from single-photon tomography. In the filtered back projection algorithm, the only part of the reconstruction process requiring user interaction is the selection of the window function. Since the ramp and window filters have different purposes, they can be separated, placing the window at the end of the reconstruction process as a three-dimensional filter. All stages of reconstruction except the window filtering are performed before the physician begins to interpret the study. The three-dimensional filtering is performed very rapidly with use of the Chebyshev convolution algorithm. A 64 x 64 x 64 pixel cube of data is filtered in 13-33 s using filters of 3-11 lengths. Smaller volumes of image data can be filtered in less than 1 s; thus, the user can interactively choose any desired filter for a given tomographic study at the time of interpretation of the images.

Mesh:

Year:  1989        PMID: 2787746     DOI: 10.1007/bf00253792

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  12 in total

1.  Interactive digital filtering of gated cardiac studies during cine display.

Authors:  T R Miller; R J Hagge; J W Wallis; K S Sampathkumaran
Journal:  IEEE Trans Med Imaging       Date:  1988       Impact factor: 10.048

2.  Enhancement of SPECT images by Fourier filtering the projection image set.

Authors:  M T Madsen; C H Park
Journal:  J Nucl Med       Date:  1985-04       Impact factor: 10.057

3.  Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters.

Authors:  M A King; R B Schwinger; B C Penney; P W Doherty; J A Bianco
Journal:  J Nucl Med       Date:  1986-08       Impact factor: 10.057

4.  Interactive visual optimization of SPECT prereconstruction filtering.

Authors:  M A King; S J Glick; B C Penney; R B Schwinger; P W Doherty
Journal:  J Nucl Med       Date:  1987-07       Impact factor: 10.057

5.  Fast count-dependent digital filtering of nuclear medicine images: concise communication.

Authors:  M A King; P W Doherty; R B Schwinger; D A Jacobs; R E Kidder; T R Miller
Journal:  J Nucl Med       Date:  1983-11       Impact factor: 10.057

6.  Two-dimensional filtering of SPECT images using the Metz and Wiener filters.

Authors:  M A King; R B Schwinger; P W Doherty; B C Penney
Journal:  J Nucl Med       Date:  1984-11       Impact factor: 10.057

7.  Rapid digital filtering.

Authors:  T R Miller; K S Sampathkumaran; M A King
Journal:  J Nucl Med       Date:  1983-07       Impact factor: 10.057

8.  Design and application of finite impulse response digital filters.

Authors:  T R Miller; K S Sampathkumaran
Journal:  Eur J Nucl Med       Date:  1982

9.  Digital filtering in nuclear medicine.

Authors:  T R Miller; K S Sampathkumaran
Journal:  J Nucl Med       Date:  1982-01       Impact factor: 10.057

10.  An overview of a camera-based SPECT system.

Authors:  K L Greer; R J Jaszczak; R E Coleman
Journal:  Med Phys       Date:  1982 Jul-Aug       Impact factor: 4.071

View more
  6 in total

1.  Kinetics modeling and occupancy studies of a novel C-11 PET tracer for VAChT in nonhuman primates.

Authors:  Hongjun Jin; Xiang Zhang; Xuyi Yue; Hui Liu; Junfeng Li; Hao Yang; Hubert Flores; Yi Su; Stanley M Parsons; Joel S Perlmutter; Zhude Tu
Journal:  Nucl Med Biol       Date:  2015-11-07       Impact factor: 2.408

2.  Kinetic modeling of [18 F]VAT, a novel radioligand for positron emission tomography imaging vesicular acetylcholine transporter in non-human primate brain.

Authors:  Hongjun Jin; Xuyi Yue; Hui Liu; Junbin Han; Hubert Flores; Yi Su; Stanley M Parsons; Joel S Perlmutter; Zhude Tu
Journal:  J Neurochem       Date:  2018-03-25       Impact factor: 5.372

3.  In Vivo Characterization of Two 18F-Labeled PDE10A PET Radioligands in Nonhuman Primate Brains.

Authors:  Hui Liu; Hongjun Jin; Zonghua Luo; Xuyi Yue; Xiang Zhang; Hubert Flores; Yi Su; Joel S Perlmutter; Zhude Tu
Journal:  ACS Chem Neurosci       Date:  2018-02-19       Impact factor: 4.418

4.  Increased sensitivity through use of overlapping 180 degrees orbits in clinical myocardial perfusion imaging.

Authors:  J W Wallis
Journal:  Eur J Nucl Med       Date:  1995-06

5.  Preclinical evaluation of a promising C-11 labeled PET tracer for imaging phosphodiesterase 10A in the brain of living subject.

Authors:  Hui Liu; Hongjun Jin; Xuyi Yue; Xiang Zhang; Hao Yang; Junfeng Li; Hubert Flores; Yi Su; Joel S Perlmutter; Zhude Tu
Journal:  Neuroimage       Date:  2015-07-26       Impact factor: 6.556

6.  Comparison of [11C]TZ1964B and [18F]MNI659 for PET imaging brain PDE10A in nonhuman primates.

Authors:  Hui Liu; Hongjun Jin; Xuyi Yue; Junbin Han; Hao Yang; Hubert Flores; Yi Su; David Alagille; Joel S Perlmutter; Gilles Tamagnan; Zhude Tu
Journal:  Pharmacol Res Perspect       Date:  2016-08-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.