Literature DB >> 8814722

Stimulating technetium-99m cerebral perfusion studies with a three-dimensional Hoffmann brain phantom: collimator and filter selection in SPECT neuroimaging.

H J Kim1, J S Karp, P D Mozley, S O Yang, D H Moon, H F Kung, H K Lee, A Alavi.   

Abstract

The choice of collimator and the selection of a filter can affect the quality of clinical SPECT images of the brain. The compromises that 4 different collimators make between spatial resolution and sensitivity were studied by imaging a three-dimensional Hoffmann brain phantom. The planar data were acquired with each collimator on a three-headed SPECT system and were reconstructed with both a standard Butterworth filter and a Wiener pre-filter. The reconstructed images were then evaluated by specialists in nuclear medicine and were also quantitatively analyzed with specific regions of interest (ROI) in the brain. All observers preferred the Wiener filter reconstructed images regardless of the collimator used to acquire the planar images. With this filter, the ultrahigh-resolution fan-beam collimator was the most subjectively preferable and quantitatively produced the highest contrast ratios. The findings support suggestions that higher resolution collimators are preferable to higher sensitivity collimators, and indicate that fan-beam collimators are preferable to parallel-hole collimators for clinical SPECT studies of cerebral perfusion. The results also suggest that Wiener filter enhances the quality of SPECT brain images regardless of which collimator is used to acquire the data.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8814722     DOI: 10.1007/bf03165071

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  15 in total

1.  Sensitivity, resolution and image quality with a multi-head SPECT camera.

Authors:  F H Fahey; B A Harkness; J W Keyes; M T Madsen; C Battisti; V Zito
Journal:  J Nucl Med       Date:  1992-10       Impact factor: 10.057

2.  Dual-isotope brain SPECT imaging with technetium-99m and iodine-123: clinical validation using xenon-133 SPECT.

Authors:  M D Devous; J K Payne; J L Lowe
Journal:  J Nucl Med       Date:  1992-11       Impact factor: 10.057

3.  Design and clinical utility of a fan beam collimator for SPECT imaging of the head.

Authors:  B M Tsui; G T Gullberg; E R Edgerton; D R Gilland; J R Perry; W H McCartney
Journal:  J Nucl Med       Date:  1986-06       Impact factor: 10.057

4.  Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters.

Authors:  M A King; R B Schwinger; B C Penney; P W Doherty; J A Bianco
Journal:  J Nucl Med       Date:  1986-08       Impact factor: 10.057

5.  Determination of the optimum filter function for SPECT imaging.

Authors:  D R Gilland; B M Tsui; W H McCartney; J R Perry; J Berg
Journal:  J Nucl Med       Date:  1988-05       Impact factor: 10.057

Review 6.  Practical considerations in gamma camera line spread function measurement.

Authors:  R K Tyson; S R Amtey
Journal:  Med Phys       Date:  1978 Nov-Dec       Impact factor: 4.071

7.  Effect of resolution improvement on required count density in ECT imaging: a computer simulation.

Authors:  G Muehllehner
Journal:  Phys Med Biol       Date:  1985-02       Impact factor: 3.609

8.  Tc-99m attenuation coefficients in water-filled phantoms determined with gamma cameras.

Authors:  C C Harris; K L Greer; R J Jaszczak; C E Floyd; E C Fearnow; R E Coleman
Journal:  Med Phys       Date:  1984 Sep-Oct       Impact factor: 4.071

9.  Quantitative SPECT reconstruction of iodine-123 data.

Authors:  D R Gilland; R J Jaszczak; K L Greer; R E Coleman
Journal:  J Nucl Med       Date:  1991-03       Impact factor: 10.057

10.  An analysis of the arterial input curve for technetium-99m-HMPAO: quantification of rCBF using single-photon emission computed tomography.

Authors:  A Pupi; M T De Cristofaro; L Bacciottini; D Antoniucci; A R Formiconi; M Mascalchi; U Meldolesi
Journal:  J Nucl Med       Date:  1991-08       Impact factor: 10.057

View more
  3 in total

1.  Optimisation of brain SPET and portability of normal databases.

Authors:  Leighton R Barnden; Rochelle L Hatton; Setayesh Behin-Ain; Brian F Hutton; Elizabeth A Goble
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-11-29       Impact factor: 9.236

2.  Differences in [99mTc]TRODAT-1 SPECT binding to dopamine transporters in patients with multiple system atrophy and Parkinson's disease.

Authors:  Randel L Swanson; Andrew B Newberg; Paul D Acton; Andrew Siderowf; Nancy Wintering; Abass Alavi; P David Mozley; Karl Plossl; Michelle Udeshi; Howard Hurtig
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-10-02       Impact factor: 9.236

Review 3.  60 Years of Achievements by KSNM in Neuroimaging Research.

Authors:  Jae Seung Kim; Hye Joo Son; Minyoung Oh; Dong Yun Lee; Hae Won Kim; Jungsu Oh
Journal:  Nucl Med Mol Imaging       Date:  2022-01-15
  3 in total