Literature DB >> 8318350

Optimization of Butterworth filter for brain SPECT imaging.

S Minoshima1, H Maruno, N Yui, T Togawa, F Kinoshita, M Kubota, K L Berger, Y Uchida, K Uno, N Arimizu.   

Abstract

A method has been described to optimize the cutoff frequency of the Butterworth filter for brain SPECT imaging. Since a computer simulation study has demonstrated that separation between an object signal and the random noise in projection images in a spatial-frequency domain is influenced by the total number of counts, the cutoff frequency of the Butterworth filter should be optimized for individual subjects according to total counts in a study. To reveal the relationship between the optimal cutoff frequencies and total counts in brain SPECT study, we used a normal volunteer and 99mTc hexamethyl-propyleneamine oxime (HMPAO) to obtain projection sets with different total counts. High quality images were created from a projection set with an acquisition time of 300-seconds per projection. The filter was optimized by calculating mean square errors from high quality images visually inspecting filtered reconstructed images. Dependence between total counts and optimal cutoff frequencies was clearly demonstrated in a nonogram. Using this nomogram, the optimal cutoff frequency for each study can be estimated from total counts, maximizing visual image quality. The results suggest that the cutoff frequency of Butterworth filter should be determined by referring to total counts in each study.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8318350     DOI: 10.1007/bf03164571

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  11 in total

1.  Clinical SPRINT imaging. Preliminary results compared to conventional SPECT brain scanning using Tc-99m HMPAO.

Authors:  J M Mountz; W L Rogers; M W Wilson; N H Clinthorne; M D Gross; N N Speed; J A Schwartz
Journal:  Clin Nucl Med       Date:  1991-08       Impact factor: 7.794

2.  Brain perfusion SPECT using an annular single crystal camera: initial clinical experience.

Authors:  B L Holman; P A Carvalho; R E Zimmerman; K A Johnson; S S Tumeh; A P Smith; S Genna
Journal:  J Nucl Med       Date:  1990-09       Impact factor: 10.057

3.  A new apparatus for brain imaging: four-head rotating gamma camera single-photon emission computed tomograph.

Authors:  K Kimura; K Hashikawa; H Etani; A Uehara; T Kozuka; H Moriwaki; Y Isaka; M Matsumoto; T Kamada; H Moriyama
Journal:  J Nucl Med       Date:  1990-05       Impact factor: 10.057

4.  Enhancement of SPECT images by Fourier filtering the projection image set.

Authors:  M T Madsen; C H Park
Journal:  J Nucl Med       Date:  1985-04       Impact factor: 10.057

5.  Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters.

Authors:  M A King; R B Schwinger; B C Penney; P W Doherty; J A Bianco
Journal:  J Nucl Med       Date:  1986-08       Impact factor: 10.057

6.  Determination of the optimum filter function for SPECT imaging.

Authors:  D R Gilland; B M Tsui; W H McCartney; J R Perry; J Berg
Journal:  J Nucl Med       Date:  1988-05       Impact factor: 10.057

7.  Interactive visual optimization of SPECT prereconstruction filtering.

Authors:  M A King; S J Glick; B C Penney; R B Schwinger; P W Doherty
Journal:  J Nucl Med       Date:  1987-07       Impact factor: 10.057

8.  Fast count-dependent digital filtering of nuclear medicine images: concise communication.

Authors:  M A King; P W Doherty; R B Schwinger; D A Jacobs; R E Kidder; T R Miller
Journal:  J Nucl Med       Date:  1983-11       Impact factor: 10.057

9.  Two-dimensional filtering of SPECT images using the Metz and Wiener filters.

Authors:  M A King; R B Schwinger; P W Doherty; B C Penney
Journal:  J Nucl Med       Date:  1984-11       Impact factor: 10.057

10.  Technetium-99m d,l-HM-PAO: a new radiopharmaceutical for SPECT imaging of regional cerebral blood perfusion.

Authors:  R D Neirinckx; L R Canning; I M Piper; D P Nowotnik; R D Pickett; R A Holmes; W A Volkert; A M Forster; P S Weisner; J A Marriott
Journal:  J Nucl Med       Date:  1987-02       Impact factor: 10.057

View more
  3 in total

Review 1.  Understanding Fourier space and filter selection.

Authors:  I G Zubal; G Wisniewski
Journal:  J Nucl Cardiol       Date:  1997 May-Jun       Impact factor: 5.952

2.  Filtering in SPECT Image Reconstruction.

Authors:  Maria Lyra; Agapi Ploussi
Journal:  Int J Biomed Imaging       Date:  2011-06-23

3.  Experimental evaluation of absolute quantification in 99m Tc-TRODAT-1 SPECT/CT brain dopamine transporter (DAT) studies.

Authors:  Norasma Amira Zainudin; Nadiah Zulkifli; Khadijah Hamid; Hazlin Hashim; Syahir Mansor
Journal:  J Appl Clin Med Phys       Date:  2022-07-14       Impact factor: 2.243

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.