Literature DB >> 24374943

Experimental characterization of two-dimensional spot profiles for two proton pencil beam scanning nozzles.

Liyong Lin1, Christopher G Ainsley, Timothy D Solberg, James E McDonough.   

Abstract

Dose calculation for pencil beam scanning proton therapy requires accurate measurement of the broad tails of the proton spot profiles for every nozzle in clinical use. By applying a pair/magnification method and merging film data, 200 mm × 240 mm dose kernels extending to 10(-4) of the central spot dose are generated for six selected energies of the IBA dedicated and universal nozzles (DN and UN). One-dimensional, circular profiles up to 100 mm in radius are generated from the asymmetric profiles to facilitate spot profile comparison. For the highest energy, 225 MeV, the output of both the DN and the UN for field sizes from 40 to 200 mm increases in parallel, slowest at the surface (∼1%) and fastest at a depth of 150 mm (∼9%). In contrast, at the lowest energy, 100 MeV, the output of the DN across the same range of field sizes increases 3-4% versus 6-7% for the UN throughout all the depths. The charge deficits in the measured depth-dose of Bragg peaks are similar between the UN and the DN. At 100 MeV, the field size factor difference at the surface between two orientations of a rectangular 40 mm × 200 mm field is 1.4% at isocentre for the DN versus 2% for the UN. Though the one-dimensional distributions are similar for the primary and tail components at different positions, the primary components of the DN spots are more elliptical 270 mm upstream than at isocentre.

Mesh:

Substances:

Year:  2013        PMID: 24374943     DOI: 10.1088/0031-9155/59/2/493

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  17 in total

1.  Toward improved target conformity for two spot scanning proton therapy delivery systems using dynamic collimation.

Authors:  Alexandra Moignier; Edgar Gelover; Blake R Smith; Dongxu Wang; Ryan T Flynn; Maura L Kirk; Liyong Lin; Timothy D Solberg; Alexander Lin; Daniel E Hyer
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

2.  Proton range verification in homogeneous materials through acoustic measurements.

Authors:  Wei Nie; Kevin C Jones; Scott Petro; Alireza Kassaee; Chandra M Sehgal; Stephen Avery
Journal:  Phys Med Biol       Date:  2018-01-17       Impact factor: 3.609

3.  Investigating aperture-based approximations to model a focused dynamic collimation system for pencil beam scanning proton therapy.

Authors:  Nicholas P Nelson; Wesley S Culberson; Daniel E Hyer; Blake R Smith; Ryan T Flynn; Patrick M Hill
Journal:  Biomed Phys Eng Express       Date:  2022-02-18

4.  Development of a storage phosphor imaging system for proton pencil beam spot profile determination.

Authors:  Jufri Setianegara; Thomas R Mazur; Yao Hao; Deshan Yang; H Harold Li
Journal:  Med Phys       Date:  2021-08-10       Impact factor: 4.506

5.  Pencil beam scanning dosimetry for large animal irradiation.

Authors:  Liyong Lin; Timothy D Solberg; Alexandro Carabe; James E Mcdonough; Eric Diffenderfer; Jenine K Sanzari; Ann R Kennedy; Keith Cengel
Journal:  J Radiat Res       Date:  2014-05-22       Impact factor: 2.724

6.  Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance.

Authors:  Liyong Lin; Minglei Kang; Timothy D Solberg; Thierry Mertens; Christian Baeumer; Christopher G Ainsley; James E McDonough
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

7.  Use of a radial projection to reduce the statistical uncertainty of spot lateral profiles generated by Monte Carlo simulation.

Authors:  Xiaoning Ding; Wei Liu; Jiajian Shen; Aman Anand; Joshua B Stoker; Yanle Hu; Martin Bues
Journal:  J Appl Clin Med Phys       Date:  2017-09-18       Impact factor: 2.102

8.  Comparing proton treatment plans of pediatric brain tumors in two pencil beam scanning nozzles with different spot sizes.

Authors:  John C Kralik; Liwen Xi; Timothy D Solberg; Charles B Simone; Liyong Lin
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

9.  A benchmarking method to evaluate the accuracy of a commercial proton monte carlo pencil beam scanning treatment planning system.

Authors:  Liyong Lin; Sheng Huang; Minglei Kang; Petri Hiltunen; Reynald Vanderstraeten; Jari Lindberg; Sami Siljamaki; Todd Wareing; Ian Davis; Allen Barnett; John McGhee; Charles B Simone; Timothy D Solberg; James E McDonough; Christopher Ainsley
Journal:  J Appl Clin Med Phys       Date:  2017-02-02       Impact factor: 2.102

10.  Innovations and the Use of Collimators in the Delivery of Pencil Beam Scanning Proton Therapy.

Authors:  Daniel E Hyer; Laura C Bennett; Theodore J Geoghegan; Martin Bues; Blake R Smith
Journal:  Int J Part Ther       Date:  2021-06-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.