Literature DB >> 7082139

Volume fluctuations in the residual limbs of lower limb amputees.

G R Fernie, P J Holliday.   

Abstract

This study evaluated residual limb volume fluctuations of new and mature amputees in order to better plan for definitive limb prostheses. A measurement system based on a water displacement technique was used to measure cross-sectional area profiles of lower extremity amputation residual limbs. Reliable data were obtained for 32 of the 49 subjects participating in this study. Residual limb shrinkage cannot be characterized by any single pattern and therefore the date for fitting of a final prosthesis cannot be predicted precisely from regular volume measurements. Every amputee studied demonstrated an increase in body weight. Changes in residual limb volume early postoperatively were dictated by interaction of shrinkage and opposite effect of weight gain . Mature amputation limbs were observed to fluctuate in volume, and these fluctuations tended to correspond to body weight changes. For 3 general patterns of volume change observed early postoperatively, the best estimate of time to fit a final prosthesis appears to be about 150 days postamputation.

Entities:  

Mesh:

Year:  1982        PMID: 7082139

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  20 in total

1.  Assessment technique for computer-aided manufactured sockets.

Authors:  Joan E Sanders; Michael R Severance
Journal:  J Rehabil Res Dev       Date:  2011

2.  Central fabrication: carved positive assessment.

Authors:  Joan E Sanders; Michael R Severance; Timothy R Myers; Marcia A Ciol
Journal:  Prosthet Orthot Int       Date:  2011-03       Impact factor: 1.895

3.  How do sock ply changes affect residual-limb fluid volume in people with transtibial amputation?

Authors:  Joan E Sanders; Daniel S Harrison; Katheryn J Allyn; Timothy R Myers; Marcia A Ciol; Elaine C Tsai
Journal:  J Rehabil Res Dev       Date:  2012

Review 4.  Residual limb volume change: systematic review of measurement and management.

Authors:  Joan E Sanders; Stefania Fatone
Journal:  J Rehabil Res Dev       Date:  2011

5.  CAD/CAM transtibial prosthetic sockets from central fabrication facilities: how accurate are they?

Authors:  Joan E Sanders; Ellen L Rogers; Elizabeth A Sorenson; Gregory S Lee; Daniel C Abrahamson
Journal:  J Rehabil Res Dev       Date:  2007

6.  COMPARATIVE EFFECTIVENESS OF AN ADJUSTABLE TRANSFEMORAL PROSTHETIC INTERFACE ACCOMMODATING VOLUME FLUCTUATION: CASE STUDY.

Authors:  Jason T Kahle; Tyler D Klenow; M Jason Highsmith
Journal:  Technol Innov       Date:  2016-09

7.  Wireless sensors for continuous, multimodal measurements at the skin interface with lower limb prostheses.

Authors:  Jean Won Kwak; Mengdi Han; Zhaoqian Xie; Ha Uk Chung; Jong Yoon Lee; Raudel Avila; Jessica Yohay; Xuexian Chen; Cunman Liang; Manish Patel; Inhwa Jung; Jongwon Kim; Myeong Namkoong; Kyeongha Kwon; Xu Guo; Christopher Ogle; Dominic Grande; Dennis Ryu; Dong Hyun Kim; Surabhi Madhvapathy; Claire Liu; Da Som Yang; Yoonseok Park; Ryan Caldwell; Anthony Banks; Shuai Xu; Yonggang Huang; Stefania Fatone; John A Rogers
Journal:  Sci Transl Med       Date:  2020-12-16       Impact factor: 17.956

8.  Effects of socket size on metrics of socket fit in trans-tibial prosthesis users.

Authors:  Joan E Sanders; Robert T Youngblood; Brian J Hafner; John C Cagle; Jake B McLean; Christian B Redd; Colin R Dietrich; Marcia A Ciol; Katheryn J Allyn
Journal:  Med Eng Phys       Date:  2017-04-01       Impact factor: 2.242

9.  A Bioimpedance Analysis Platform for Amputee Residual Limb Assessment.

Authors:  Joan E Sanders; Mark A Moehring; Travis M Rothlisberger; Reid H Phillips; Tyler Hartley; Colin R Dietrich; Christian B Redd; David W Gardner; John C Cagle
Journal:  IEEE Trans Biomed Eng       Date:  2015-11-19       Impact factor: 4.538

10.  Self-reported prosthetic sock use among persons with transtibial amputation.

Authors:  Krittika D'Silva; Brian J Hafner; Katheryn J Allyn; Joan E Sanders
Journal:  Prosthet Orthot Int       Date:  2013-08-28       Impact factor: 1.895

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.