Literature DB >> 11392649

State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: a review.

A F Mak1, M Zhang, D A Boone.   

Abstract

Scientific studies have been conducted to quantify attributes that may be important in the creation of more functional and comfortable lower-limb prostheses. The prosthesis socket, a human-machine interface, has to be designed properly to achieve satisfactory load transmission, stability, and efficient control for mobility. The biomechanical understanding of the interaction between prosthetic socket and the residual limb is fundamental to such goals. The purpose of this paper is to review the recent research literature on socket biomechanics, including socket pressure measurement, friction-related phenomena and associated properties, computational modeling, and limb tissue responses to external mechanical loads and other physical conditions at the interface. There is no doubt that improved biomechanical understanding has advanced the science of socket fitting. However, the most recent advances in the understanding of stresses experienced at the residual limb have not yet led to enough clinical consensus that could fundamentally alter clinical practice. Efforts should be made to systematically identify the major discrepancies. Further research should be directed to address the critical controversies and the associated technical challenges. Developments should be guided to offer clinicians the quantification and visualization of the interaction between the residual limb and the prosthetic socket. An understanding of comfort and optimal load transfer as patterns of socket interface stress could culminate in socket design expert systems.

Entities:  

Mesh:

Year:  2001        PMID: 11392649

Source DB:  PubMed          Journal:  J Rehabil Res Dev        ISSN: 0748-7711


  28 in total

1.  Progression of bone ingrowth and attachment strength for stability of percutaneous osseointegrated prostheses.

Authors:  Sujee Jeyapalina; J Peter Beck; Roy D Bloebaum; Kent N Bachus
Journal:  Clin Orthop Relat Res       Date:  2014-10       Impact factor: 4.176

2.  A digital patient for computer-aided prosthesis design.

Authors:  Giorgio Colombo; Giancarlo Facoetti; Caterina Rizzi
Journal:  Interface Focus       Date:  2013-04-06       Impact factor: 3.906

3.  Effect of prosthetic alignment changes on socket reaction moment impulse during walking in transtibial amputees.

Authors:  Toshiki Kobayashi; Michael S Orendurff; Adam K Arabian; Teri G Rosenbaum-Chou; David A Boone
Journal:  J Biomech       Date:  2014-02-14       Impact factor: 2.712

4.  Percutaneous osseointegrated prostheses for amputees: Limb compensation in a 12-month ovine model.

Authors:  Trevor J Shelton; J Peter Beck; Roy D Bloebaum; Kent N Bachus
Journal:  J Biomech       Date:  2011-09-13       Impact factor: 2.712

5.  Instrumented socket inserts for sensing interaction at the limb-socket interface.

Authors:  Eric C Swanson; Jake B McLean; Katheryn J Allyn; Christian B Redd; Joan E Sanders
Journal:  Med Eng Phys       Date:  2017-12-08       Impact factor: 2.242

Review 6.  Design features of implants for direct skeletal attachment of limb prostheses.

Authors:  M Pitkin
Journal:  J Biomed Mater Res A       Date:  2013-04-02       Impact factor: 4.396

7.  Stakeholder perspectives for possible residual limb monitoring system for persons with lower-limb amputation.

Authors:  Lilly Tran; Ryan Caldwell; Matthew Quigley; Stefania Fatone
Journal:  Disabil Rehabil       Date:  2018-09-05       Impact factor: 3.033

8.  Osseointegrated Prosthetic Implants for People With Lower-Limb Amputation: A Health Technology Assessment.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2019-12-12

9.  Considering passive mechanical properties and patient user motor performance in lower limb prosthesis design optimization to enhance rehabilitation outcomes.

Authors:  Matthew J Major; Nicholas P Fey
Journal:  Phys Ther Rev       Date:  2017-07-17

10.  Residual limb volume fluctuations in transfemoral amputees.

Authors:  Linda Paternò; Michele Ibrahimi; Elisa Rosini; Giuseppe Menfi; Vito Monaco; Emanuele Gruppioni; Leonardo Ricotti; Arianna Menciassi
Journal:  Sci Rep       Date:  2021-06-10       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.