Literature DB >> 34086567

Divergence-Free Constrained Phase Unwrapping and Denoising for 4D Flow MRI Using Weighted Least-Squares.

Jiacheng Zhang, Sean M Rothenberger, Melissa C Brindise, Michael B Scott, Haben Berhane, Justin J Baraboo, Michael Markl, Vitaliy L Rayz, Pavlos P Vlachos.   

Abstract

A novel divergence-free constrained phase unwrapping method was proposed and evaluated for 4D flow MRI. The unwrapped phase field was obtained by integrating the phase variations estimated from the wrapped phase data using weighted least-squares. The divergence-free constraint for incompressible blood flow was incorporated to regulate and denoise the resulting phase field. The proposed method was tested on synthetic phase data of left ventricular flow and in vitro 4D flow measurement of Poiseuille flow. The method was additionally applied to in vivo 4D flow measurements in the thoracic aorta from 30 human subjects. The performance of the proposed method was compared to the state-of-the-art 4D single-step Laplacian algorithm. The synthetic phase data were completely unwrapped by the proposed method for all the cases with velocity encoding (venc) as low as 20% of the maximum velocity and signal-to-noise ratio as low as 5. The in vitro Poiseuille flow data were completely unwrapped with a 60% increase in the velocity-to-noise ratio. For the in-vivo aortic datasets with venc ratio less than 0.4, the proposed method significantly improved the success rate by as much as 40% and reduced the velocity error levels by a factor of 10 compared to the state-of-the-art method. The divergence-free constrained method exhibits reliability and robustness on phase unwrapping and shows improved accuracy of velocity and hemodynamic quantities by unwrapping the low-venc 4D flow MRI data.

Entities:  

Mesh:

Year:  2021        PMID: 34086567      PMCID: PMC8714458          DOI: 10.1109/TMI.2021.3086331

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  42 in total

1.  New robust 3-D phase unwrapping algorithms: application to magnetic field mapping and undistorting echoplanar images.

Authors:  R Cusack; N Papadakis
Journal:  Neuroimage       Date:  2002-07       Impact factor: 6.556

2.  Reconstruction of divergence-free velocity fields from cine 3D phase-contrast flow measurements.

Authors:  Julia Busch; Daniel Giese; Lukas Wissmann; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2012-03-12       Impact factor: 4.668

3.  Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters.

Authors:  Olaf Dietrich; José G Raya; Scott B Reeder; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2007-08       Impact factor: 4.813

4.  Optimal Dual-VENC Unwrapping in Phase-Contrast MRI.

Authors:  Hugo Carrillo; Axel Osses; Sergio Uribe; Cristobal Bertoglio
Journal:  IEEE Trans Med Imaging       Date:  2018-11-21       Impact factor: 10.048

5.  Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio.

Authors:  A T Lee; G B Pike; N J Pelc
Journal:  Magn Reson Med       Date:  1995-01       Impact factor: 4.668

6.  Practical signal-to-noise ratio quantification for sensitivity encoding: application to coronary MR angiography.

Authors:  Jing Yu; Harsh Agarwal; Matthias Stuber; Michael Schär
Journal:  J Magn Reson Imaging       Date:  2011-06       Impact factor: 4.813

7.  Comparison of SNR and CNR for in vivo mouse brain imaging at 3 and 7 T using well matched scanner configurations.

Authors:  M W DiFrancesco; J M Rasmussen; W Yuan; R Pratt; S Dunn; B J Dardzinski; S K Holland
Journal:  Med Phys       Date:  2008-09       Impact factor: 4.071

8.  4D Flow MRI Pressure Estimation Using Velocity Measurement-Error-Based Weighted Least-Squares.

Authors:  Jiacheng Zhang; Melissa C Brindise; Sean Rothenberger; Susanne Schnell; Michael Markl; David Saloner; Vitaliy L Rayz; Pavlos P Vlachos
Journal:  IEEE Trans Med Imaging       Date:  2019-11-21       Impact factor: 11.037

9.  Non-invasive pressure difference estimation from PC-MRI using the work-energy equation.

Authors:  Fabrizio Donati; C Alberto Figueroa; Nicolas P Smith; Pablo Lamata; David A Nordsletten
Journal:  Med Image Anal       Date:  2015-09-08       Impact factor: 8.545

10.  Computational fluid dynamics simulations of blood flow regularized by 3D phase contrast MRI.

Authors:  Vinicius C Rispoli; Jon F Nielsen; Krishna S Nayak; Joao L A Carvalho
Journal:  Biomed Eng Online       Date:  2015-11-26       Impact factor: 2.819

View more
  1 in total

1.  Accelerated dual-venc 4D flow MRI with variable high-venc spatial resolution for neurovascular applications.

Authors:  Maria Aristova; Jianing Pang; Yue Ma; Liliana Ma; Haben Berhane; Vitaliy Rayz; Michael Markl; Susanne Schnell
Journal:  Magn Reson Med       Date:  2022-06-26       Impact factor: 3.737

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.