Literature DB >> 12169259

New robust 3-D phase unwrapping algorithms: application to magnetic field mapping and undistorting echoplanar images.

R Cusack1, N Papadakis.   

Abstract

The phase, as well as the magnitude, of MRI images can carry useful information. It may be used to encode flow or temperature, or to map the magnetic field for the undistorting of EPIs and automated shimming. In all cases, we measure the extra spin given to nuclei. Unfortunately, we can only measure the final phase of the spins: the rotation is wrapped into the range [-pi, +pi], and to obtain a measure of the parameter of interest the missing multiples of 2pi must be replaced--a process known as phase unwrapping. While simple in principle, standard phase unwrapping algorithms fail catastrophically in the presence of even small amounts of noise. Here we present a new algorithm for robust three-dimensional phase unwrapping, in which unwrapping is guided, so that it initially works on less noisy regions. We test the algorithm on simulated phase data, and on maps of magnetic field, which were then used to successfully undistort EPI images. The unwrapping algorithm could be directly applied to other kinds of phase data.

Mesh:

Year:  2002        PMID: 12169259     DOI: 10.1006/nimg.2002.1092

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  68 in total

1.  Cerebral microbleeds: burden assessment by using quantitative susceptibility mapping.

Authors:  Tian Liu; Krishna Surapaneni; Min Lou; Liuquan Cheng; Pascal Spincemaille; Yi Wang
Journal:  Radiology       Date:  2011-11-04       Impact factor: 11.105

2.  Simultaneous quantitative susceptibility mapping (QSM) and R2* for high iron concentration quantification with 3D ultrashort echo time sequences: An echo dependence study.

Authors:  Xing Lu; Yajun Ma; Eric Y Chang; Qun He; Adam Searleman; Annette von Drygalski; Jiang Du
Journal:  Magn Reson Med       Date:  2018-01-04       Impact factor: 4.668

3.  Zero and first-order phase shift correction for field map estimation with dual-echo GRE using bipolar gradients.

Authors:  Desmond T B Yeo; Thomas L Chenevert; Jeffrey A Fessler; Boklye Kim
Journal:  Magn Reson Imaging       Date:  2007-04-18       Impact factor: 2.546

4.  Magnetic susceptibility-weighted MR phase imaging of the human brain.

Authors:  Alexander Rauscher; Jan Sedlacik; Markus Barth; Hans-Joachim Mentzel; Jürgen R Reichenbach
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

5.  Mitigation of partial volume effects in susceptibility-based oxygenation measurements by joint utilization of magnitude and phase (JUMP).

Authors:  Patrick McDaniel; Berkin Bilgic; Audrey P Fan; Jeffrey N Stout; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2016-04-05       Impact factor: 4.668

6.  Clinical Integration of Automated Processing for Brain Quantitative Susceptibility Mapping: Multi-Site Reproducibility and Single-Site Robustness.

Authors:  Pascal Spincemaille; Zhe Liu; Shun Zhang; Ilhami Kovanlikaya; Matteo Ippoliti; Marcus Makowski; Richard Watts; Ludovic de Rochefort; Vijay Venkatraman; Patricia Desmond; Mathieu D Santin; Stéphane Lehéricy; Brian H Kopell; Patrice Péran; Yi Wang
Journal:  J Neuroimaging       Date:  2019-08-04       Impact factor: 2.486

7.  Sensitive and automated detection of iron-oxide-labeled cells using phase image cross-correlation analysis.

Authors:  Parker H Mills; Yi-Jen L Wu; Chien Ho; Eric T Ahrens
Journal:  Magn Reson Imaging       Date:  2008-05-02       Impact factor: 2.546

8.  Robust phase unwrapping for MR temperature imaging using a magnitude-sorted list, multi-clustering algorithm.

Authors:  Florian Maier; David Fuentes; Jeffrey S Weinberg; John D Hazle; R Jason Stafford
Journal:  Magn Reson Med       Date:  2014-05-08       Impact factor: 4.668

9.  Multicenter reproducibility of quantitative susceptibility mapping in a gadolinium phantom using MEDI+0 automatic zero referencing.

Authors:  Kofi Deh; Keigo Kawaji; Marjolein Bulk; Louise Van Der Weerd; Emelie Lind; Pascal Spincemaille; Kelly McCabe Gillen; Johan Van Auderkerke; Yi Wang; Thanh D Nguyen
Journal:  Magn Reson Med       Date:  2018-10-04       Impact factor: 4.668

10.  Enhanced positive-contrast visualization of paramagnetic contrast agents using phase images.

Authors:  Parker H Mills; Eric T Ahrens
Journal:  Magn Reson Med       Date:  2009-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.