Literature DB >> 22411739

Reconstruction of divergence-free velocity fields from cine 3D phase-contrast flow measurements.

Julia Busch1, Daniel Giese, Lukas Wissmann, Sebastian Kozerke.   

Abstract

Three-dimensional phase-contrast velocity vector field mapping shows great potential for clinical applications; however measurement inaccuracies may limit the utility and robustness of the technique. While parts of the error in the measured velocity fields can be minimized by background phase estimation in static tissue and magnetic field monitoring, considerable inaccuracies remain. The present work introduces divergence-reduction processing of 3D phase-contrast flow data based on a synergistic combination of normalized convolution and divergence-free radial basis functions. It is demonstrated that this approach effectively addresses erroneous flow for image reconstructions from both fully sampled and undersampled data. Using computer simulations and in vivo data acquired in the aorta of healthy subjects and a stenotic valve patient it is shown that divergence arising from measurement imperfections can be reduced by up to 87% resulting in improved vector field representations. Based on the results obtained it is concluded that integration of the divergence-free condition into postprocessing of vector fields presents an efficient approach to addressing flow field inaccuracies.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22411739     DOI: 10.1002/mrm.24221

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  A clinical method for mapping and quantifying blood stasis in the left ventricle.

Authors:  Lorenzo Rossini; Pablo Martinez-Legazpi; Vi Vu; Leticia Fernández-Friera; Candelas Pérez Del Villar; Sara Rodríguez-López; Yolanda Benito; María-Guadalupe Borja; David Pastor-Escuredo; Raquel Yotti; María J Ledesma-Carbayo; Andrew M Kahn; Borja Ibáñez; Francisco Fernández-Avilés; Karen May-Newman; Javier Bermejo; Juan C Del Álamo
Journal:  J Biomech       Date:  2015-11-30       Impact factor: 2.712

2.  3D cine phase-contrast MRI at 3T in intracranial aneurysms compared with patient-specific computational fluid dynamics.

Authors:  P van Ooij; J J Schneiders; H A Marquering; C B Majoie; E van Bavel; A J Nederveen
Journal:  AJNR Am J Neuroradiol       Date:  2013-04-18       Impact factor: 3.825

3.  Merging computational fluid dynamics and 4D Flow MRI using proper orthogonal decomposition and ridge regression.

Authors:  Ali Bakhshinejad; Ahmadreza Baghaie; Alireza Vali; David Saloner; Vitaliy L Rayz; Roshan M D'Souza
Journal:  J Biomech       Date:  2017-05-17       Impact factor: 2.712

4.  Virtual injections using 4D flow MRI with displacement corrections and constrained probabilistic streamlines.

Authors:  Grant S Roberts; Michael W Loecher; Alma Spahic; Kevin M Johnson; Patrick A Turski; Laura B Eisenmenger; Oliver Wieben
Journal:  Magn Reson Med       Date:  2021-12-31       Impact factor: 4.668

5.  Wall Shear Stress Estimation for 4D Flow MRI Using Navier-Stokes Equation Correction.

Authors:  Jiacheng Zhang; Sean M Rothenberger; Melissa C Brindise; Michael Markl; Vitaliy L Rayz; Pavlos P Vlachos
Journal:  Ann Biomed Eng       Date:  2022-08-09       Impact factor: 4.219

6.  Assessment of 4D flow MRI's quality by verifying its Navier-Stokes compatibility.

Authors:  Jeremías Garay; Hernán Mella; Julio Sotelo; Cristian Cárcamo; Sergio Uribe; Cristóbal Bertoglio; Joaquín Mura
Journal:  Int J Numer Method Biomed Eng       Date:  2022-05-09       Impact factor: 2.648

7.  Robust 4D flow denoising using divergence-free wavelet transform.

Authors:  Frank Ong; Martin Uecker; Umar Tariq; Albert Hsiao; Marcus T Alley; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-02-18       Impact factor: 4.668

8.  Accuracy of 4D Flow Measurement of Cerebrospinal Fluid Dynamics in the Cervical Spine: An In Vitro Verification Against Numerical Simulation.

Authors:  Soroush Heidari Pahlavian; Alexander C Bunck; Suraj Thyagaraj; Daniel Giese; Francis Loth; Dennis M Hedderich; Jan Robert Kröger; Bryn A Martin
Journal:  Ann Biomed Eng       Date:  2016-04-04       Impact factor: 3.934

9.  Divergence-Free Constrained Phase Unwrapping and Denoising for 4D Flow MRI Using Weighted Least-Squares.

Authors:  Jiacheng Zhang; Sean M Rothenberger; Melissa C Brindise; Michael B Scott; Haben Berhane; Justin J Baraboo; Michael Markl; Vitaliy L Rayz; Pavlos P Vlachos
Journal:  IEEE Trans Med Imaging       Date:  2021-11-30       Impact factor: 10.048

10.  Enhancement of cerebrovascular 4D flow MRI velocity fields using machine learning and computational fluid dynamics simulation data.

Authors:  David R Rutkowski; Alejandro Roldán-Alzate; Kevin M Johnson
Journal:  Sci Rep       Date:  2021-05-13       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.