Comparison of SNR and CNR for in vivo mouse brain imaging at 3 and 7 T using well matched scanner configurations.

M W DiFrancesco1, J M Rasmussen, W Yuan, R Pratt, S Dunn, B J Dardzinski, S K Holland.   

Abstract

Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for magnetic resonance microimaging were measured using two nearly identical magnetic resonance imaging (MRI) scanners operating at field strengths of 3 and 7 T. Six mice were scanned using two imaging protocols commonly applied for in vivo imaging of small animal brain: RARE and FLASH. An accounting was made of the field dependence of relaxation times as well as a small number of hardware disparities between scanner systems. Standard methods for relaxometry were utilized to measure T1 and T2 for two white matter (WM) and two gray matter (GM) regions in the mouse brain. An average increase in T1 between 3 and 7 T of 28% was observed in the brain. T2 was found to decrease by 27% at 7 T in agreement with theoretical models. The SNR was found to be uniform throughout the mouse brain, increasing at higher field by a factor statistically indistinguishable from the ratio of Larmor frequencies when imaging with either method. The CNR between GM and WM structures was found to adhere to the expected field dependence for the RARE imaging sequence. Improvement in the CNR for the FLASH imaging sequence between 3 and 7 T was observed to be greater than the Larmor ratio, reflecting a greater susceptibility to partial volume effects at the lower SNR values at 3 T. Imaging at 7 T versus 3 T in small animals clearly provides advantages with respect to the CNR, even beyond the Larmor ratio, especially in lower SNR regimes. This careful multifaceted assessment of the benefits of higher static field is instructive for those newly embarking on small animal imaging. Currently the number of 7 T MRI scanners in use for research in human subjects is increasing at a rapid pace with approximately 30 systems deployed worldwide in 2008. The data presented in this article verify that if system performance and radio frequency uniformity is optimized at 7 T, it should be possible to realize the expected improvements in the CNR and SNR compared with MRI at 3 T.

Entities:  

Mesh:

Year:  2008        PMID: 18841848      PMCID: PMC2809704          DOI: 10.1118/1.2968092

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  23 in total

1.  Imaging brain function in humans at 7 Tesla.

Authors:  E Yacoub; A Shmuel; J Pfeuffer; P F Van De Moortele; G Adriany; P Andersen; J T Vaughan; H Merkle; K Ugurbil; X Hu
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  NMR relaxation times in the human brain at 3.0 tesla.

Authors:  J P Wansapura; S K Holland; R S Dunn; W S Ball
Journal:  J Magn Reson Imaging       Date:  1999-04       Impact factor: 4.813

3.  Nuclear relaxation of human brain gray and white matter: analysis of field dependence and implications for MRI.

Authors:  H W Fischer; P A Rinck; Y Van Haverbeke; R N Muller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

Review 4.  Whole-body MRI at high field: technical limits and clinical potential.

Authors:  Fritz Schick
Journal:  Eur Radiol       Date:  2005-01-27       Impact factor: 5.315

5.  T1, T2 relaxation and magnetization transfer in tissue at 3T.

Authors:  Greg J Stanisz; Ewa E Odrobina; Joseph Pun; Michael Escaravage; Simon J Graham; Michael J Bronskill; R Mark Henkelman
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

6.  Small-animal MRI: signal-to-noise ratio comparison at 7 and 1.5 T with multiple-animal acquisition strategies.

Authors:  Olivier Beuf; Franck Jaillon; Hervé Saint-Jalmes
Journal:  MAGMA       Date:  2006-09-07       Impact factor: 2.310

7.  MR relaxation times in human brain: measurement at 4 T.

Authors:  P Jezzard; S Duewell; R S Balaban
Journal:  Radiology       Date:  1996-06       Impact factor: 11.105

8.  Imaging of the active B1 field in vivo.

Authors:  R Stollberger; P Wach
Journal:  Magn Reson Med       Date:  1996-02       Impact factor: 4.668

9.  Theory of NMR signal behavior in magnetically inhomogeneous tissues: the static dephasing regime.

Authors:  D A Yablonskiy; E M Haacke
Journal:  Magn Reson Med       Date:  1994-12       Impact factor: 4.668

10.  Anomalous transverse relaxation in 1H spectroscopy in human brain at 4 Tesla.

Authors:  S Posse; C A Cuenod; R Risinger; D Le Bihan; R S Balaban
Journal:  Magn Reson Med       Date:  1995-02       Impact factor: 4.668

View more
  9 in total

1.  Deep residual network for off-resonance artifact correction with application to pediatric body MRA with 3D cones.

Authors:  David Y Zeng; Jamil Shaikh; Signy Holmes; Ryan L Brunsing; John M Pauly; Dwight G Nishimura; Shreyas S Vasanawala; Joseph Y Cheng
Journal:  Magn Reson Med       Date:  2019-05-22       Impact factor: 4.668

2.  Multishot PROPELLER for high-field preclinical MRI.

Authors:  Prachi Pandit; Yi Qi; Jennifer Story; Kevin F King; G Allan Johnson
Journal:  Magn Reson Med       Date:  2010-07       Impact factor: 4.668

3.  Diffusion tensor imaging correlates with cytopathology in a rat model of neonatal hydrocephalus.

Authors:  Weihong Yuan; Kelley E Deren; James P McAllister; Scott K Holland; Diana M Lindquist; Alessandro Cancelliere; Melissa Mason; Ahmed Shereen; Dean A Hertzler; Mekibib Altaye; Francesco T Mangano
Journal:  Cerebrospinal Fluid Res       Date:  2010-11-05

Review 4.  Biomolecular MRI reporters: Evolution of new mechanisms.

Authors:  Arnab Mukherjee; Hunter C Davis; Pradeep Ramesh; George J Lu; Mikhail G Shapiro
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2017-06-03       Impact factor: 9.795

5.  Divergence-Free Constrained Phase Unwrapping and Denoising for 4D Flow MRI Using Weighted Least-Squares.

Authors:  Jiacheng Zhang; Sean M Rothenberger; Melissa C Brindise; Michael B Scott; Haben Berhane; Justin J Baraboo; Michael Markl; Vitaliy L Rayz; Pavlos P Vlachos
Journal:  IEEE Trans Med Imaging       Date:  2021-11-30       Impact factor: 10.048

6.  Post-mortem magnetic resonance microscopy (MRM) of the murine brain at 7 Tesla results in a gain of resolution as compared to in vivo MRM.

Authors:  Oliver von Bohlen Und Halbach; Martin Lotze; Jörg P Pfannmöller
Journal:  Front Neuroanat       Date:  2014-06-13       Impact factor: 3.856

7.  Cardiac MRI Assessment of Mouse Myocardial Infarction and Regeneration.

Authors:  Yijen L Wu
Journal:  Methods Mol Biol       Date:  2021

8.  Optimization of molecularly targeted MRI in the brain: empirical comparison of sequences and particles.

Authors:  Niloufar Zarghami; Alexandre A Khrapitchev; Francisco Perez-Balderas; Manuel Sarmiento Soto; James R Larkin; Luca Bau; Nicola R Sibson
Journal:  Int J Nanomedicine       Date:  2018-07-25

9.  Development and validation of a new MRI simulation technique that can reliably estimate optimal in vivo scanning parameters in a glioblastoma murine model.

Authors:  Andrea Protti; Kristen L Jones; Dennis M Bonal; Lei Qin; Letterio S Politi; Sasha Kravets; Quang-Dé Nguyen; Annick D Van den Abbeele
Journal:  PLoS One       Date:  2018-07-23       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.