Literature DB >> 30476460

Virtual Monochromatic Dual-Energy Aortoiliac CT Angiography With Reduced Iodine Dose: A Prospective Randomized Study.

Manuel Patino1, Anushri Parakh1, Grace C Lo1, Mukta Agrawal1, Avinash R Kambadakone1, George R Oliveira1, Dushyant V Sahani1.   

Abstract

OBJECTIVE: The purpose of this study was to assess the feasibility of performing abdominopelvic aortoiliac CT angiography (CTA) with 16.0 g of iodine contrast medium acquired with low-energy (40 and 50 keV) virtual monochromatic (VMC) images with rapid-kilovoltage-switching dual-energy CT. SUBJECTS AND METHODS: A total of 52 adults with abdominal aortoiliac aneurysm and prior 120-kVp single-energy CTA (SECTA) with 33 g iodine (standard dose) underwent follow-up dual-energy CTA (DECTA) with a 52% reduced iodine dose. Subjects were randomly assigned to a contrast medium protocol for DECTA examinations: one group (n = 26) received 16.2 g (270 mg I/mL) and the other (n = 26) received 16.0 g (320 mg I/mL). Two readers independently assessed SECTA and VMC DECTA datasets for image quality using a 5-point scale. Aortoiliac intravascular attenuation was measured, and ANOVA was used to compare measurements between VMC DECTA and SECTA images. In a subset of patients with DECTA after endovascular aortic repair, endoleak detection was evaluated on VMC images. Volume CT dose index, dose-length product, and size-specific dose estimate were compared between DECTA and SECTA.
RESULTS: All DECTA examinations (n = 52) were rated diagnostic with image quality scores comparable to those of 120-kVp single-energy CTA (40 keV, 4.2-4.4; 50 keV, 4.6-4.8; SECTA, 4.4-4.5). Intravascular attenuation was uniform in all reduced-iodine DECTA examinations and was significantly higher on 40- and 50-keV images than on standard-iodine-dose SECTA images (720 ± 125 HU and 482 ± 82 HU vs 303 ± 65 HU) (p < 0.01). There was no difference in intravascular attenuation between the 16.2-g and the 16.0-g doses (p = 0.82). Sensitivity and specificity for endoleak detection were 78.9-94.7% and 100%. Total dose-length product was lower for DECTA (788 ± 166 mGy · cm) than for SECTA (1114 ± 468 mGy · cm).
CONCLUSION: Low-energy VMC DECTA images (40 and 50 keV) acquired with two contrast protocols at approximately 50% reduced iodine dose (16.0 and 16.2 g) provide adequate intravascular attenuation and diagnostic quality for aortoiliac evaluation.

Entities:  

Keywords:  CT angiography; abdominal aortic aneurysm; contrast medium; iodine

Mesh:

Substances:

Year:  2018        PMID: 30476460     DOI: 10.2214/AJR.18.19935

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  7 in total

1.  Gadolinium Enhances Dual-energy Computed Tomography Scan of Pulmonary Artery.

Authors:  An Xie; Wen-Jie Sun; Yan-Feng Zeng; Peng Liu; Jian-Bin Liu; Feng Huang
Journal:  Curr Med Sci       Date:  2022-09-30

Review 2.  Recognizing and Minimizing Artifacts at Dual-Energy CT.

Authors:  Anushri Parakh; Chansik An; Simon Lennartz; Prabhakar Rajiah; Benjamin M Yeh; Frank J Simeone; Dushyant V Sahani; Avinash R Kambadakone
Journal:  Radiographics       Date:  2021-02-19       Impact factor: 5.333

3.  Optimizing the Bolus Trigger Threshold for Dual-Energy CT Angiography.

Authors:  Ashkan A Malayeri
Journal:  Radiology       Date:  2021-06-15       Impact factor: 29.146

4.  Optimizing low contrast volume thoracic CT angiography: From the basics to the advanced.

Authors:  Katherine Kaproth-Joslin; Susan Hobbs; Prabhakar Rajiah; Apeksha Chaturvedi; Abhishek Chaturvedi
Journal:  J Clin Imaging Sci       Date:  2022-07-29

5.  Reducing contrast medium dose with low photon energy images in renal dual-energy spectral CT angiography and adaptive statistical iterative reconstruction (ASIR).

Authors:  Xirong Zhang; Jing Chen; Nan Yu; Zhanli Ren; Qian Tian; Xin Tian; Yongjun Jia; Taiping He; Changyi Guo
Journal:  Br J Radiol       Date:  2021-03-12       Impact factor: 3.039

6.  Feasibility of low-dose contrast media in run-off CT angiography on dual-layer spectral detector CT.

Authors:  Haiyan Ren; Yanhua Zhen; Zheng Gong; Chuanzhuo Wang; Zhihui Chang; Jiahe Zheng
Journal:  Quant Imaging Med Surg       Date:  2021-05

7.  Evaluating the Image Quality of Monoenergetic Images From Dual-Energy Computed Tomography With Low-Concentration and Low-Flow-Rate Contrast Media for the Arterials Supply to the Nipple-Areola Complex in Breast Cancer Compared With Conventional Computed Tomography Angiography.

Authors:  Xiangfei Zeng; Xiaoxia Wang; Huifang Chen; Daihong Liu; Jinfang Shi; Jing Zhang; Xiaoqin Li; Liyin Zhang; Yi Yang; Jiuquan Zhang
Journal:  J Comput Assist Tomogr       Date:  2020 Nov/Dec       Impact factor: 2.081

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.