OBJECTIVE: : To evaluate the effects of virtual monochromatic imaging (VMI) using dual-layer spectral detector CT on the image quality of coronary CT angiography (CCTA) acquired by using a low contrast material (CM) dose. METHODS: : We used a VMI 50keV protocol with a 50% CM dose (140 mgI kg-1) to scan 30 patients with renal insufficiency and a 120 kVp with the standard CM dose (280 mgI kg-1) to scan 30 controls without renal insufficiency. Quantitative parameters, including CT attenuation, image noise, and contrast-to-noise ratio (CNR), were measured. The visual image quality factors of contrast enhancement, image noise, beam-hardening artefact, vessel sharpness, and overall image quality were scored on a 4-point scale. RESULTS: : The mean CT attenuation of the ascending aorta was significantly higher for 50 keV VMI than for 120 kVp. Image noise was significantly lower under the 50 keV VMI. CNR and the mean visual score for contrast enhancement were significantly higher for 50 keV VMI. There were no significant differences in the other visual image quality parameters between the two protocols. CONCLUSION: : Dual-layer spectral detector CT using 50 keV VMI enabled reducing the CM dose by 50 % without CCAT image quality degradation in patients with renal insufficiency. ADVANCES IN KNOWLEDGE:: The VMI 50 keV protocol using dual-layer spectral detector CT and a CM dose reduced by 50 % (140 mgI kg-1) can improve the diagnostic image quality of CCTA.
OBJECTIVE: : To evaluate the effects of virtual monochromatic imaging (VMI) using dual-layer spectral detector CT on the image quality of coronary CT angiography (CCTA) acquired by using a low contrast material (CM) dose. METHODS: : We used a VMI 50keV protocol with a 50% CM dose (140 mgI kg-1) to scan 30 patients with renal insufficiency and a 120 kVp with the standard CM dose (280 mgI kg-1) to scan 30 controls without renal insufficiency. Quantitative parameters, including CT attenuation, image noise, and contrast-to-noise ratio (CNR), were measured. The visual image quality factors of contrast enhancement, image noise, beam-hardening artefact, vessel sharpness, and overall image quality were scored on a 4-point scale. RESULTS: : The mean CT attenuation of the ascending aorta was significantly higher for 50 keV VMI than for 120 kVp. Image noise was significantly lower under the 50 keV VMI. CNR and the mean visual score for contrast enhancement were significantly higher for 50 keV VMI. There were no significant differences in the other visual image quality parameters between the two protocols. CONCLUSION: : Dual-layer spectral detector CT using 50 keV VMI enabled reducing the CM dose by 50 % without CCAT image quality degradation in patients with renal insufficiency. ADVANCES IN KNOWLEDGE:: The VMI 50 keV protocol using dual-layer spectral detector CT and a CM dose reduced by 50 % (140 mgI kg-1) can improve the diagnostic image quality of CCTA.
Authors: Rivka Kessner; Nils Große Hokamp; Les Ciancibello; Nikhil Ramaiya; Karin A Herrmann Journal: Br J Radiol Date: 2019-05-24 Impact factor: 3.039
Authors: Serena Dell'Aversana; Raffaele Ascione; Marco De Giorgi; Davide Raffaele De Lucia; Renato Cuocolo; Marco Boccalatte; Gerolamo Sibilio; Giovanni Napolitano; Giuseppe Muscogiuri; Sandro Sironi; Giuseppe Di Costanzo; Enrico Cavaglià; Massimo Imbriaco; Andrea Ponsiglione Journal: J Imaging Date: 2022-09-01
Authors: David C Rotzinger; Salim A Si-Mohamed; Jérôme Yerly; Sara Boccalini; Fabio Becce; Loïc Boussel; Reto A Meuli; Salah D Qanadli; Philippe C Douek Journal: Eur Radiol Date: 2021-03-19 Impact factor: 5.315