| Literature DB >> 33725193 |
D Dammerer1, A Keiler2, S Herrnegger1, D Putzer3, S Strasser1, M Liebensteiner1.
Abstract
INTRODUCTION: To investigate the accuracy of preoperative digital templating for total hip arthroplasty (THA) at a certified arthroplasty center (EndoCert EPZmax).Entities:
Keywords: Accuracy; Digital templating; EndoCert; Experience; Total hip arthroplasty
Mesh:
Year: 2021 PMID: 33725193 PMCID: PMC9474525 DOI: 10.1007/s00402-021-03836-w
Source DB: PubMed Journal: Arch Orthop Trauma Surg ISSN: 0936-8051 Impact factor: 2.928
Fig. 1Preoperative planning. Standardised antero-posterior view of the pelvis with a correctly placed calibration marker. MediCAD software
Demographic data of patients, distribution of BMD and primary diagnosis, mean duration of the operation and used implants
| Number of patients | |
| Female | 298 |
| Male | 280 |
| Total | 578 |
| Operated side | |
| Left | 277 |
| Right | 343 |
| Total | 620 |
| Mean age in years | 66.1 (16.7–90.3) |
| Mean BMI | 26.7 (16.9–59.2) |
| BMI (WHO classification in kg/m2) | |
| Under- or normal weight | 207 |
| Overweight | 255 |
| Obese | 157 |
| Preoperative diagnosis | |
| Primary osteoarthritis | 533 |
| Protrusion osteoarthritis | 12 |
| Femoral head necrosis | 56 |
| Hip dysplasia | 19 |
| Average duration of surgery in minutes | 67.7 (37–181) |
| Number of implanted cups | |
| Trident PSL | 544 |
| Pinnacle | 76 |
| Number of implanted stems | |
| Accolade II | 544 |
| Corail | 76 |
Fig. 2Flowchart of the study group constellation
Planning accuracy and deviation of implants in absolute values and percentage
| Cup size | Stem size | |||
|---|---|---|---|---|
| Occurrence | Percentage | Occurrence | Percentage | |
| Implant size in general | ||||
| Exact match | 315 | 51 | 320 | 52 |
| ± 1 size | 208 | 34 | 256 | 38 |
| ± 2 sizes | 66 | 11 | 35 | 7 |
| ± 3 sizes or more | 31 | 5 | 9 | 3 |
| Implant size Stryker | ||||
| Exact match | 267 | 49 | 288 | 53 |
| ± 1 size | 187 | 35 | 202 | 38 |
| ± 2 sizes | 60 | 11 | 35 | 7 |
| ± 3 sizes or more | 30 | 5 | 15 | 3 |
| Implant size DePuy Synthes | ||||
| Exact match | 48 | 63 | 32 | 42 |
| ± 1 size | 21 | 28 | 33 | 43 |
| ± 2 sizes | 6 | 8 | 10 | 13 |
| ± 3 sizes or more | 1 | 1 | 1 | 1 |
Deviation of one size is considered to be accurate
Overview of comparable literature
| Study | Year | Number of patients | Implants cup | Implants stem | General accuracy cup (exact size ± 1 size) | General accuracy stem (exact size ± 1 size) | Software |
|---|---|---|---|---|---|---|---|
| Holzer et. al. [ | 2019 | 632 | Allofit® Pinnacle® | Alloclassic® Corail® | 78% ( | 87% ( | EndoMap software® system (Siemens Medical Solutions AG, Erlangen, Germany) |
| Eggli et. al. [ | 1998 | 100 | n.a | Müller® straight | 90% ( | 92% ( | Software developed by Maurice E. Müller Foundation (Bern, Switzerland) and by Department of Bioengineering Clemson University (South Carolina, USA) |
| Davila et. al. [ | 2006 | 36 | Pinnacle® | Summit® | 86% ( | 72% ( | EndoMap® software system (Siemens Medical Solutions AG, Erlangen, Germany) |
| Gamble et. al. [ | 2010 | 40 | Trident® | Accolade® Omnifit® | 80% ( | 85% ( | OrthoView® software (version 2.0CEN, Meridian Technique Ltd, Southampton, United Kingdom) |
| Shaarani et. al. [ | 2013 | 100 | Trident® | Accolade® | 80% ( | 98% ( | OrthoView® software (version 2.0CEN, Meridian Technique Ltd, Southampton, United Kingdom) |
| Whiddon et. al. [ | 2011 | 51 | Trident® | Secur-Fit Max® Accolade® | 78% ( | 90% ( | Impax® digital templating software (Agfa, Mortsel, Belgium) |
| Wiese et. al. [ | 2020 | 56 | Pinnacle® | Summit® | 71% ( | 79% ( | Impax Orthopaedic Tools® software (Agfa, Mortsel, Belgium) |
| Carter et. al. [ | 1995 | 74 | – | Osteonics® | – | 82–96% ( | n.a |
| Efe et. al. [ | 2011 | 169 | EP-FIT-PLUS® Wagner® | Polar® Proxy Plus® | 78% ( | 82% ( | MediCAD® software (version 2.06, mediCAD Hectec GmbH, Altdorf/Landshut, Germany) |
aOnly accuracy of implanted stems was investigated. Accuracy between less ore more experienced surgeons was compared, no overall accuracy