UNLABELLED: We performed a radiologic assessment of the Trident Peripheral Self-Locking cup 2 years after implantation to assess early migration behaviour and to establish if incomplete postoperative seating correlated with early instability. A retrospective analysis of 30 cases was performed using EBRA. No cups had acetabular screws. Average total migration was 1.5 mm (range 0.1 to 5.9 mm). Seventeen showed total migration >1 mm and 7 of these showed further migration >2 mm (range 2.3 to 5.9 mm). Twenty cups demonstrated incomplete seating on initial post-operative radiographs (mean 1.4 mm, range 0.3 to 3.0). No relationship between incomplete seating and migration was identified (p = 0.86). The majority of gaps consolidated at differing times within the 2 year period. Oxford Hip scores showed significant improvement after surgery (p = 0.001) and this was independent of migration (p = 0.76). At 5 years there were no revisions for aseptic loosening. CONCLUSION: The majority of the cups demonstrated early radiographic instability, and this was not related to incomplete seating. Five year functional outcome appears good and independent of migration and initial seating.
UNLABELLED: We performed a radiologic assessment of the Trident Peripheral Self-Locking cup 2 years after implantation to assess early migration behaviour and to establish if incomplete postoperative seating correlated with early instability. A retrospective analysis of 30 cases was performed using EBRA. No cups had acetabular screws. Average total migration was 1.5 mm (range 0.1 to 5.9 mm). Seventeen showed total migration >1 mm and 7 of these showed further migration >2 mm (range 2.3 to 5.9 mm). Twenty cups demonstrated incomplete seating on initial post-operative radiographs (mean 1.4 mm, range 0.3 to 3.0). No relationship between incomplete seating and migration was identified (p = 0.86). The majority of gaps consolidated at differing times within the 2 year period. Oxford Hip scores showed significant improvement after surgery (p = 0.001) and this was independent of migration (p = 0.76). At 5 years there were no revisions for aseptic loosening. CONCLUSION: The majority of the cups demonstrated early radiographic instability, and this was not related to incomplete seating. Five year functional outcome appears good and independent of migration and initial seating.
Authors: Dietmar Dammerer; Philipp Blum; David Putzer; Andreas Tscholl; Michael C Liebensteiner; Martin Thaler Journal: Arch Orthop Trauma Surg Date: 2020-11-09 Impact factor: 3.067
Authors: Dietmar Dammerer; Philipp Blum; David Putzer; Annelies van Beeck; Michael Nogler; Martin Thaler Journal: Arch Orthop Trauma Surg Date: 2020-12-22 Impact factor: 3.067
Authors: D Dammerer; A Keiler; S Herrnegger; D Putzer; S Strasser; M Liebensteiner Journal: Arch Orthop Trauma Surg Date: 2021-03-16 Impact factor: 2.928