Literature DB >> 23100151

Two-year radiologic assessment of the Trident Peripheral Self-Locking cup using EBRA.

Perrico Nunag1, Angela H Deakin, Ezekiel Oburu, Martin Sarungi.   

Abstract

UNLABELLED: We performed a radiologic assessment of the Trident Peripheral Self-Locking cup 2 years after implantation to assess early migration behaviour and to establish if incomplete postoperative seating correlated with early instability. A retrospective analysis of 30 cases was performed using EBRA. No cups had acetabular screws. Average total migration was 1.5 mm (range 0.1 to 5.9 mm). Seventeen showed total migration >1 mm and 7 of these showed further migration >2 mm (range 2.3 to 5.9 mm). Twenty cups demonstrated incomplete seating on initial post-operative radiographs (mean 1.4 mm, range 0.3 to 3.0). No relationship between incomplete seating and migration was identified (p = 0.86). The majority of gaps consolidated at differing times within the 2 year period. Oxford Hip scores showed significant improvement after surgery (p = 0.001) and this was independent of migration (p = 0.76). At 5 years there were no revisions for aseptic loosening.
CONCLUSION: The majority of the cups demonstrated early radiographic instability, and this was not related to incomplete seating. Five year functional outcome appears good and independent of migration and initial seating.

Entities:  

Mesh:

Year:  2012        PMID: 23100151     DOI: 10.5301/HIP.2012.9744

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  6 in total

1.  Clinical evaluation of a novel press-fit acetabular cup using "Ein-Bild-Roentgen-Analysis" (EBRA): A positive short-term prognosis.

Authors:  B A Ishaque; J Wieczorek; C A Fonseca Ulloa; J B Seeger; G A Ahmed; M Rickert; A Jahnke
Journal:  J Orthop       Date:  2020-03-30

2.  Good mid-term results with the trident peripheral self-locking cup: a clinical evaluation and migration measurement with EBRA.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Andreas Tscholl; Michael C Liebensteiner; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-11-09       Impact factor: 3.067

3.  Outcome and EBRA migration analysis of a reconstruction cage in acetabular revision arthroplasty: a clinical and radiological study.

Authors:  Dietmar Dammerer; Philipp Blum; David Putzer; Annelies van Beeck; Michael Nogler; Martin Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2020-12-22       Impact factor: 3.067

4.  Different wear in two highly cross-linked polyethylene liners in THA: wear analysis with EBRA.

Authors:  D Dammerer; A Keiler; D Putzer; F Lenze; M Liebensteiner; M Thaler
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-04       Impact factor: 3.067

5.  Primary stability of two uncementedacetabular components of different geometry: hemispherical or peripherallyenhanced?

Authors:  G Antoniades; E J Smith; A H Deakin; S C Wearing; M Sarungi
Journal:  Bone Joint Res       Date:  2013-12-10       Impact factor: 5.853

6.  Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study.

Authors:  D Dammerer; A Keiler; S Herrnegger; D Putzer; S Strasser; M Liebensteiner
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-16       Impact factor: 2.928

  6 in total