Literature DB >> 3659989

Measurement and restoration of equality in length of the lower limbs in total hip replacement.

V Hoikka1, T Paavilainen, T S Lindholm, K B Turula, M Ylikoski.   

Abstract

Alteration of the length of the lower limb was measured in 39 patients undergoing total hip replacement. Radiographs were taken in the erect posture prior to operation and 6 months postoperatively. The inequality of limb length was measured by the difference between the height of the vertices of the femoral heads and by the difference between the lowest points of the ischial tuberosities. The change of the length was measured intraoperatively as the difference observed between two reference points: one above the acetabulum and the other on the proximal femur. Good correlation was obtained between the change of the limb length made intraoperatively and the change in the limb length using the ischial tuberosities as reference points; no correlation was observed when the vertices of the femoral heads were the reference points. Inequality of limb length can be radiologically determined before and after total hip arthroplasty. Femoral and prosthetic heads are not good reference points for measurement. The difference in the height of the ischial tuberosities demonstrates inequality of limb functional length as it reflects the tilting of the pelvis.

Entities:  

Mesh:

Year:  1987        PMID: 3659989     DOI: 10.1007/bf00350537

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  18 in total

1.  A study of lower extremity length inequality.

Authors:  W A RUSH; H A STEINER
Journal:  Am J Roentgenol Radium Ther       Date:  1946-11

2.  Roentgenographic measurements after Müller total hip replacement. Correlations among roentgenographic measurements and hip strength and mobility.

Authors:  D R Gore; M P Murray; G M Gardner; S B Sepic
Journal:  J Bone Joint Surg Am       Date:  1977-10       Impact factor: 5.284

3.  A simple method of obtaining equal leg length in total hip arthroplasty.

Authors:  H M McGee; J H Scott
Journal:  Clin Orthop Relat Res       Date:  1985-04       Impact factor: 4.176

4.  A method of intraoperative limb length measurement in total hip arthroplasty.

Authors:  S T Woolson; W H Harris
Journal:  Clin Orthop Relat Res       Date:  1985-04       Impact factor: 4.176

5.  Studies in osteoarthritis of the hip. IV. Biomechanics and clinical considerations.

Authors:  J P Gofton
Journal:  Can Med Assoc J       Date:  1971-06-05       Impact factor: 8.262

6.  Accurate determination of leg lengths during total hip replacement.

Authors:  W E Knight
Journal:  Clin Orthop Relat Res       Date:  1977 Mar-Apr       Impact factor: 4.176

7.  Clinical symptoms and biomechanics of lumbar spine and hip joint in leg length inequality.

Authors:  O Friberg
Journal:  Spine (Phila Pa 1976)       Date:  1983-09       Impact factor: 3.468

8.  Weight-bearing radiography in total hip replacement.

Authors:  K B Turula; O Friberg; J Haajanen; T S Lindholm; K Tallroth
Journal:  Skeletal Radiol       Date:  1985       Impact factor: 2.199

9.  The effect of postural scoliosis on lumbar apophyseal joints.

Authors:  L G Giles; J R Taylor
Journal:  Scand J Rheumatol       Date:  1984       Impact factor: 3.641

10.  Studies in osteoarthritis of the hip. II. Osteoarthritis of the hip and leg-length disparity.

Authors:  J P Gofton; G E Trueman
Journal:  Can Med Assoc J       Date:  1971-05-08       Impact factor: 8.262

View more
  7 in total

1.  Digital templating in total knee and hip replacement: an analysis of planning accuracy.

Authors:  Bettina Kniesel; Lukas Konstantinidis; Anja Hirschmüller; Norbert Südkamp; Peter Helwig
Journal:  Int Orthop       Date:  2013-10-27       Impact factor: 3.075

2.  Leg length discrepancy and osteoarthritis in the knee, hip and lumbar spine.

Authors:  Kelvin J Murray; Michael F Azari
Journal:  J Can Chiropr Assoc       Date:  2015-09

3.  Is it Important to Know Where to Place the Spherical Marker for Hip Replacement Digital Planning?

Authors:  Giancarlo Cavalli Polesello; Thiago Tronco Salerno; João Hélio Zucarelli Rezende; Marcelo Cavalheiro de Queiroz; Nayra Deise Rabelo; Walter Ricioli Junior
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2019-11-07

4.  The accuracy of digital templating in uncemented total hip arthroplasty.

Authors:  Lukas A Holzer; Georg Scholler; Stefan Wagner; Jörg Friesenbichler; Werner Maurer-Ertl; Andreas Leithner
Journal:  Arch Orthop Trauma Surg       Date:  2018-12-06       Impact factor: 3.067

5.  Pre-operative templating in THA using a short stem system: precision and accuracy of 2D versus 3D planning method.

Authors:  Patrick Reinbacher; Maria Anna Smolle; Joerg Friesenbichler; Alexander Draschl; Andreas Leithner; Werner Maurer-Ertl
Journal:  J Orthop Traumatol       Date:  2022-03-22

6.  Is There Any Difference Between a Spherical Marker and a Simple Coin for Hip Replacement Digital Planning?

Authors:  Giancarlo Cavalli Polesello; Thiago Tronco Salerno; Marcelo Cavalheiro de Queiroz; Walter Ricioli Junior; Nayra Deise Anjos Rabelo; Emerson Kyioshi Honda
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2022-01-24

7.  Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study.

Authors:  D Dammerer; A Keiler; S Herrnegger; D Putzer; S Strasser; M Liebensteiner
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-16       Impact factor: 2.928

  7 in total