Literature DB >> 29781288

Is computerised 3D templating more accurate than 2D templating to predict size of components in primary total hip arthroplasty?

Erik Schiffner1, David Latz1, Pascal Jungbluth1, Jan P Grassmann1, Stephan Tanner1, Alfred Karbowski2, Joachim Windolf1, Johannes Schneppendahl1.   

Abstract

INTRODUCTION: The aim of this study was to compare the accuracy of preoperative templating in total hip arthroplasty (THA) using conventional 2-dimensional (2D) and computed tomography (CT)-based 3-dimensional (3D) measures.
METHODS: One hundred and sixteen consecutive primary THAs were analysed. The preoperative diagnosis was primary osteoarthritis in all cases. The 2D templating and the 3D templating were performed by two different residents. All templating results were available for the orthopaedic surgeon performing the procedure. Accuracies with regard to the predicted and actual implant sizes were determined for each procedure. Implantation of the size as planned was defined as "exact", whereas the use of components within one size larger or smaller (±1) as planned were defined as "accurate."
RESULTS: The 3D templating was significantly more accurate in predicting implant sizing compared to 2D templating for primary total hip arthroplasty (THA). The difference was statistically significant for the cup templating (''exact'' p = 0.02; ''accurate'' p = 0.01) and for the stem templating (''exact'' p = 0.04; ''accurate'' p = 0.01).
CONCLUSION: Our results support the superiority of 3D templating over 2D templating in predicting implant size.

Entities:  

Keywords:  3D templating; Cup; hip; stem; total hip arthroplasty

Mesh:

Year:  2018        PMID: 29781288     DOI: 10.1177/1120700018776311

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  5 in total

1.  Artificial intelligence for distinguishment of hammering sound in total hip arthroplasty.

Authors:  Yasuhiro Homma; Shun Ito; Xu Zhuang; Tomonori Baba; Kazutoshi Fujibayashi; Kazuo Kaneko; Yu Nishiyama; Muneaki Ishijima
Journal:  Sci Rep       Date:  2022-06-14       Impact factor: 4.996

2.  Conventional computed tomography software can be used for accurate pre-operative templating in bipolar hip arthroplasty: A preliminary report.

Authors:  Nobuaki Chinzei; Mitsuaki Noda; Hiroshi Nashiki; Takehiko Matsushita; Atsuyuki Inui; Shinya Hayashi
Journal:  J Clin Orthop Trauma       Date:  2020-09-06

Review 3.  Comparison of the accuracy of 2D and 3D templating methods for planning primary total hip replacement: a systematic review and meta-analysis.

Authors:  Habeeb Bishi; Joshua B V Smith; Vipin Asopa; Richard E Field; Chao Wang; David H Sochart
Journal:  EFORT Open Rev       Date:  2022-01-11

4.  Determining the accuracy of preoperative total hip replacement 2D templating using the mediCAD® software.

Authors:  Seyed Peyman Mirghaderi; Sadula Sharifpour; Alireza Moharrami; Negar Ahmadi; Rangarirai Makuku; Maryam Salimi; Seyed Mohammad Javad Mortazavi
Journal:  J Orthop Surg Res       Date:  2022-04-10       Impact factor: 2.359

5.  Accuracy of digital templating of uncemented total hip arthroplasty at a certified arthroplasty center: a retrospective comparative study.

Authors:  D Dammerer; A Keiler; S Herrnegger; D Putzer; S Strasser; M Liebensteiner
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-16       Impact factor: 2.928

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.