Literature DB >> 33558636

Influence of embedding media on the accuracy of working length determination by means of apex locator: an ex vivo study.

Thomas Gerhard Wolf1,2, Anna Krauß-Mironjuk3, Richard Johannes Wierichs4, Benjamín Briseño-Marroquín4,3.   

Abstract

The aim of this research was to determine ex vivo the influence on accuracy of five different embedding media, for investigative and educational purposes, and one electronic apex locator. 110 human extracted mature roots of permanent single-rooted human teeth were used. The roots were embedded in alginate, stick sponge, 2% agar-agar and 6% and 12% gelatin. The actual working length to the physiological foramen was determined under a stereo-microscope (16 ×) and the electronic working lengths with the Elements Diagnostic Unit and a K-file ISO 10. The accuracy ranges of the accumulated measurements, when allowing a ± 0.5 mm tolerance, went from 98.2% (6% and 12% gelatin), 93.7% (alginate), 92.8% (2% agar-agar) to 91.7% (sponge). The exact measurements at the physiological foramen ranged from 80.0% (6% gelatin), 76.5% (2% agar-agar), 71.8% (12% gelatin), 68.2% (alginate) to 64.5% (sponge). Although relatively seldom (n = 24), measurements with deviations of more than ± 0.5 mm were also observed; thus, the accuracy of the working length determination results per se can be considered as clinically acceptable. The results of this research allow a recommendation of the investigated embedding media for electronic working length determination models for educational and research purposes in endodontics.

Entities:  

Year:  2021        PMID: 33558636     DOI: 10.1038/s41598-021-82942-6

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  45 in total

1.  Treatment outcome in endodontics-the Toronto Study. Phase II: initial treatment.

Authors:  Mahsa Farzaneh; Sarah Abitbol; Herenia P Lawrence; Shimon Friedman
Journal:  J Endod       Date:  2004-05       Impact factor: 4.171

2.  Factors affecting the long-term results of endodontic treatment.

Authors:  U Sjogren; B Hagglund; G Sundqvist; K Wing
Journal:  J Endod       Date:  1990-10       Impact factor: 4.171

3.  [Influence of magnification tools on the recognition of simulated preparation and filling errors].

Authors:  Balthasar Zaugg; Alexandros Stassinakis; Peter Hotz
Journal:  Schweiz Monatsschr Zahnmed       Date:  2004

Review 4.  Apical limit of root canal instrumentation and obturation, part 1. Literature review.

Authors:  D Ricucci
Journal:  Int Endod J       Date:  1998-11       Impact factor: 5.264

5.  In vitro evaluation of the ability of three apex locators to determine the working length during retreatment.

Authors:  Fernando Goldberg; Benjamín Briseño Marroquín; Santiago Frajlich; Cristian Dreyer
Journal:  J Endod       Date:  2005-09       Impact factor: 4.171

6.  Accuracy of root length determination using Tri Auto ZX and ProTaper instruments: an in vitro study.

Authors:  Everdan Carneiro; Clovis Monteiro Bramante; Fábio Picoli; Ariadne Letra; Ulisses Xavier da Silva Neto; Renato Menezes
Journal:  J Endod       Date:  2006-02       Impact factor: 4.171

7.  Influence of instrument size on the accuracy of different apex locators: an in vitro study.

Authors:  Benjamín Briseño-Marroquín; Santiago Frajlich; Fernando Goldberg; Brita Willershausen
Journal:  J Endod       Date:  2008-04-11       Impact factor: 4.171

8.  Current trends in endodontic treatment by general dental practitioners: report of a United States national survey.

Authors:  Gina M Savani; Wael Sabbah; Christine M Sedgley; Brian Whitten
Journal:  J Endod       Date:  2014-03-26       Impact factor: 4.171

9.  [Root canal treatment in Switzerland. The quantitative aspects--a determination of its status].

Authors:  F Barbakow; F Lutz; L Tóth
Journal:  Schweiz Monatsschr Zahnmed       Date:  1995

10.  The evaluation of four electronic apex locators in teeth with simulated horizontal oblique root fractures.

Authors:  Fernando Goldberg; Santiago Frajlich; Sergio Kuttler; Emilio Manzur; Benjamín Briseño-Marroquín
Journal:  J Endod       Date:  2008-10-18       Impact factor: 4.171

View more
  1 in total

1.  Effect of Sodium Hypochlorite Concentration on Electronic Apex Locator Reliability.

Authors:  Franck Diemer; Emma Plews; Marie Georgelin-Gurgel; Lora Mishra; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2022-01-23       Impact factor: 3.623

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.