Literature DB >> 15551606

Apical limit of root canal instrumentation and obturation, part 1. Literature review.

D Ricucci1.   

Abstract

One of the major controversies in root canal therapy concerns the apical limit of instrumentation and obturation. The results of longitudinal prognostic studies, basic anatomical knowledge of the apical third of the root canal, and the histological pulp reaction to caries progression demonstrated the presence of a vital apical pulp remnant, even in the presence of a periapical lesion. Finally necrosis and bacteria establish themselves in the periapical lesion. All valid prognosis studies confirm the practice of staying short of the apex with a homogeneous obturation to obtain the highest success rate of 90-94% (when done by or under supervision of specialists; results in the general population had a failure rate greater than 50%). The location of the apical foramen(ina) related to root canal treatment most frequently ends short of the apex, often by several millimetres.

Entities:  

Mesh:

Year:  1998        PMID: 15551606     DOI: 10.1046/j.1365-2591.1998.00184.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  31 in total

1.  Evaluation of the multifrequency electronic apex locator Joypex 5 in primary teeth.

Authors:  E J N L Silva; D R Herrera; E J Souza-Júnior; T P Rosa
Journal:  Eur Arch Paediatr Dent       Date:  2013-07-24

Review 2.  Shaping the root canal system.

Authors:  M Waplington; A S McRobert
Journal:  Br Dent J       Date:  2014-03       Impact factor: 1.626

3.  An ex vivo comparison of working length determination by three electronic root canal length measurement devices integrated into endodontic rotary motors.

Authors:  Manal Maree Ali; Ronald Wigler; Shaul Lin; Arieh Y Kaufman
Journal:  Clin Oral Investig       Date:  2016-07-09       Impact factor: 3.573

4.  Coculture of stem cells from apical papilla and human umbilical vein endothelial cell under hypoxia increases the formation of three-dimensional vessel-like structures in vitro.

Authors:  Changyong Yuan; Penglai Wang; Lifang Zhu; Waruna Lakmal Dissanayaka; David William Green; Edith H Y Tong; Lijian Jin; Chengfei Zhang
Journal:  Tissue Eng Part A       Date:  2014-12-23       Impact factor: 3.845

5.  Effect of Sodium Hypochlorite Concentration on Electronic Apex Locator Reliability.

Authors:  Franck Diemer; Emma Plews; Marie Georgelin-Gurgel; Lora Mishra; Hyeon-Cheol Kim
Journal:  Materials (Basel)       Date:  2022-01-23       Impact factor: 3.623

6.  Comparative evaluation of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  Saru Jain; Ravi Kapur
Journal:  Contemp Clin Dent       Date:  2012-09

7.  Efficiency of 2 electronic apex locators on working length determination: A clinical study.

Authors:  Sibel Koçak; Mustafa Murat Koçak; Baran Can Sağlam
Journal:  J Conserv Dent       Date:  2013-05

8.  Survey of attitudes, materials and methods preferred in root canal therapy by general dental practice in Turkey: Part 1.

Authors:  Gul Celik Unal; Bulem Ureyen Kaya; Ali Gurhan Tac; Ayse Diljin Kececi
Journal:  Eur J Dent       Date:  2012-10

9.  Tooth resorption part I - pathogenesis and case series of internal resorption.

Authors:  Marina Fernandes; Ida de Ataide; Rahul Wagle
Journal:  J Conserv Dent       Date:  2013-01

10.  The effect of file size on the accuracy of the raypex 5 apex locator: an in vitro study.

Authors:  Shiva Sadeghi; Masoomeh Abolghasemi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2008-05-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.