Literature DB >> 33236945

Application of Adaptive Image Receive Coil Technology for Whole-Brain Imaging.

Petrice M Cogswell1, Joshua D Trzasko1,2, Erin M Gray1, Norbert G Campeau1, Phillip J Rossman1, Daehun Kang1, Fraser Robb3, Robert S Stormont3, Scott A Lindsay3, Matt A Bernstein4, Kiaran P McGee2,4, John Huston1.   

Abstract

OBJECTIVE. The Adaptive Image Receive (AIR) radiofrequency coil is an emergent technology that is lightweight and flexible and exhibits electrical characteristics that overcome many of the limitations of traditional rigid coil designs. The purpose of this study was to apply the AIR coil for whole-brain imaging and compare the performance of a prototype AIR coil array with the performance of conventional head coils. SUBJECTS AND METHODS. A phantom and 15 healthy adult participants were imaged. A prototype 16-channel head AIR coil was compared with conventional 8-and 32-channel head coils using clinically available MRI sequences. During consensus review, two board-certified neuroradiologists graded the AIR coil compared with an 8-channel coil and a 32-channel coil on a 5-point ordinal scale in multiple categories. One- and two-sided Wilcoxon signed rank tests were performed. Noise covariance matrices and geometry factor (g-factor) maps were calculated. RESULTS. The signal-to-noise ratio, structural sharpness, and overall image quality scores of the prototype 16-channel AIR coil were better than those of the 8-channel coil but were not as good as those of the 32-channel coil. Noise covariance matrices showed stable performance of the AIR coil across participants. The median g-factors for the 16-channel AIR coil were, overall, less than those of the 8-channel coil but were greater than those of the 32-channel coil. CONCLUSION. On average, the prototype 16-channel head AIR coil outperformed a conventional 8-channel head coil but did not perform as well as a conventional 32-channel head coil. This study shows the feasibility of the novel AIR coil technology for imaging the brain and provides insight for future coil design improvements.

Entities:  

Keywords:  Adaptive Image Receive (AIR) coil; brain imaging; multielement receive-only coils

Mesh:

Year:  2020        PMID: 33236945      PMCID: PMC7968701          DOI: 10.2214/AJR.20.22812

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  16 in total

1.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

2.  B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.

Authors:  Paul T Weavers; Shengzhen Tao; Joshua D Trzasko; Louis M Frigo; Yunhong Shu; Matthew A Frick; Seung-Kyun Lee; Thomas K-F Foo; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2017-06-21       Impact factor: 4.668

3.  An introduction to coil array design for parallel MRI.

Authors:  Michael A Ohliger; Daniel K Sodickson
Journal:  NMR Biomed       Date:  2006-05       Impact factor: 4.044

4.  Mechanically adjustable coil array for wrist MRI.

Authors:  J A Nordmeyer-Massner; N De Zanche; K P Pruessmann
Journal:  Magn Reson Med       Date:  2009-02       Impact factor: 4.668

5.  Characterization and evaluation of a flexible MRI receive coil array for radiation therapy MR treatment planning using highly decoupled RF circuits.

Authors:  Kiaran P McGee; Robert S Stormont; Scott A Lindsay; Victor Taracila; Dennis Savitskij; Fraser Robb; Robert J Witte; Timothy J Kaufmann; John Huston; Stephen J Riederer; Eric A Borisch; Phillip J Rossman
Journal:  Phys Med Biol       Date:  2018-04-13       Impact factor: 3.609

6.  Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

Authors:  Philip M Robson; Aaron K Grant; Ananth J Madhuranthakam; Riccardo Lattanzi; Daniel K Sodickson; Charles A McKenzie
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

7.  Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems.

Authors:  Shengzhen Tao; Paul T Weavers; Joshua D Trzasko; Yunhong Shu; John Huston; Seung-Kyun Lee; Louis M Frigo; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2016-07-04       Impact factor: 4.668

8.  Screen-printed flexible MRI receive coils.

Authors:  Joseph R Corea; Anita M Flynn; Balthazar Lechêne; Greig Scott; Galen D Reed; Peter J Shin; Michael Lustig; Ana C Arias
Journal:  Nat Commun       Date:  2016-03-10       Impact factor: 14.919

9.  Flexible 23-channel coil array for high-resolution magnetic resonance imaging at 3 Tesla.

Authors:  Roberta Frass-Kriegl; Lucia Isabel Navarro de Lara; Michael Pichler; Jürgen Sieg; Ewald Moser; Christian Windischberger; Elmar Laistler
Journal:  PLoS One       Date:  2018-11-01       Impact factor: 3.240

Review 10.  RF coils: A practical guide for nonphysicists.

Authors:  Bernhard Gruber; Martijn Froeling; Tim Leiner; Dennis W J Klomp
Journal:  J Magn Reson Imaging       Date:  2018-06-13       Impact factor: 4.813

View more
  5 in total

Review 1.  Compact pediatric cardiac magnetic resonance imaging protocols.

Authors:  Evan J Zucker
Journal:  Pediatr Radiol       Date:  2022-07-12

2.  Characterization of a Low-Profile, Flexible, and Acoustically Transparent Receive-Only MRI Coil Array for High Sensitivity MR-Guided Focused Ultrasound.

Authors:  Isabelle Saniour; Fraser J L Robb; Victor Taracila; Vishwas Mishra; Jana Vincent; Henning U Voss; Michael G Kaplitt; J Levi Chazen; Simone Angela Winkler
Journal:  IEEE Access       Date:  2022-02-25       Impact factor: 3.476

3.  Improved Brain MR Imaging from a Compact, Lightweight 3T Scanner with High-Performance Gradients.

Authors:  Emanuele Camerucci; Norbert G Campeau; Joshua D Trzasko; Erin M Gray; Matt A Bernstein; Petrice M Cogswell; Yunhong Shu; Thomas K Foo; John Huston
Journal:  J Magn Reson Imaging       Date:  2021-06-28       Impact factor: 4.813

Review 4.  Multi-nuclear magnetic resonance spectroscopy: state of the art and future directions.

Authors:  Yi Wei; Caiwei Yang; Hanyu Jiang; Qian Li; Feng Che; Shang Wan; Shan Yao; Feifei Gao; Tong Zhang; Jiazheng Wang; Bin Song
Journal:  Insights Imaging       Date:  2022-08-17

5.  Application of Highly Flexible Adaptive Image Receive Coil for Lung MR Imaging Using Zero TE Sequence: Comparison with Conventional Anterior Array Coil.

Authors:  Kyungsoo Bae; Kyung Nyeo Jeon; Moon Jung Hwang; Yunsub Jung; Joonsung Lee
Journal:  Diagnostics (Basel)       Date:  2022-01-08
  5 in total