Literature DB >> 18816810

Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

Philip M Robson1, Aaron K Grant, Ananth J Madhuranthakam, Riccardo Lattanzi, Daniel K Sodickson, Charles A McKenzie.   

Abstract

Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal-to-noise ratio and g-factor and is demonstrated for SENSE and GRAPPA reconstructions for accelerated acquisitions that have not previously been amenable to such assessment. Only a simple "prescan" measurement of noise amplitude and correlation in the phased-array receiver, and a single accelerated image acquisition are required, allowing robust assessment of signal-to-noise ratio and g-factor. The "pseudo multiple replica" method has been rigorously validated in phantoms and in vivo, showing excellent agreement with true multiple replica and analytical methods. This method is universally applicable to the parallel imaging reconstruction techniques used in clinical applications and will allow pixel-by-pixel image noise measurements for all parallel imaging strategies, allowing quantitative comparison between arbitrary k-space trajectories, image reconstruction, or noise conditioning techniques. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18816810      PMCID: PMC2838249          DOI: 10.1002/mrm.21728

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Advances in sensitivity encoding with arbitrary k-space trajectories.

Authors:  K P Pruessmann; M Weiger; P Börnert; P Boesiger
Journal:  Magn Reson Med       Date:  2001-10       Impact factor: 4.668

3.  A generalized approach to parallel magnetic resonance imaging.

Authors:  D K Sodickson; C A McKenzie
Journal:  Med Phys       Date:  2001-08       Impact factor: 4.071

4.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

5.  The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study.

Authors:  Derek K Jones
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

6.  Parallel imaging reconstruction using automatic regularization.

Authors:  Fa-Hsuan Lin; Kenneth K Kwong; John W Belliveau; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2004-03       Impact factor: 4.668

7.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

8.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

9.  Signal-to-noise measurements in magnitude images from NMR phased arrays.

Authors:  C D Constantinides; E Atalar; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

10.  2D SENSE for faster 3D MRI.

Authors:  Markus Weiger; Klaas P Pruessmann; Peter Boesiger
Journal:  MAGMA       Date:  2002-03       Impact factor: 2.533

View more
  124 in total

1.  Low rank alternating direction method of multipliers reconstruction for MR fingerprinting.

Authors:  Jakob Assländer; Martijn A Cloos; Florian Knoll; Daniel K Sodickson; Jürgen Hennig; Riccardo Lattanzi
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

2.  Measuring signal-to-noise ratio in partially parallel imaging MRI.

Authors:  Frank L Goerner; Geoffrey D Clarke
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

3.  Acoustic noise reduction in T 1- and proton-density-weighted turbo spin-echo imaging.

Authors:  Martin Ott; Martin Blaimer; Felix Breuer; David Grodzki; Björn Heismann; Peter Jakob
Journal:  MAGMA       Date:  2015-10-22       Impact factor: 2.310

4.  Diffusion MRI noise mapping using random matrix theory.

Authors:  Jelle Veraart; Els Fieremans; Dmitry S Novikov
Journal:  Magn Reson Med       Date:  2015-11-24       Impact factor: 4.668

5.  A GRAPPA algorithm for arbitrary 2D/3D non-Cartesian sampling trajectories with rapid calibration.

Authors:  Tianrui Luo; Douglas C Noll; Jeffrey A Fessler; Jon-Fredrik Nielsen
Journal:  Magn Reson Med       Date:  2019-05-03       Impact factor: 4.668

6.  A circular echo planar sequence for fast volumetric fMRI.

Authors:  Christoph Rettenmeier; Danilo Maziero; Yongxian Qian; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2018-10-01       Impact factor: 4.668

7.  Scan-specific robust artificial-neural-networks for k-space interpolation (RAKI) reconstruction: Database-free deep learning for fast imaging.

Authors:  Mehmet Akçakaya; Steen Moeller; Sebastian Weingärtner; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2018-09-18       Impact factor: 4.668

8.  Sparsity-promoting calibration for GRAPPA accelerated parallel MRI reconstruction.

Authors:  Daniel S Weller; Jonathan R Polimeni; Leo Grady; Lawrence L Wald; Elfar Adalsteinsson; Vivek K Goyal
Journal:  IEEE Trans Med Imaging       Date:  2013-04-09       Impact factor: 10.048

9.  Water-fat MRI for assessing changes in bone marrow composition due to radiation and chemotherapy in gynecologic cancer patients.

Authors:  Patrick J Bolan; Luke Arentsen; Thanasak Sueblinvong; Yan Zhang; Steen Moeller; Jori S Carter; Levi S Downs; Rahel Ghebre; Douglas Yee; Jerry Froelich; Susanta Hui
Journal:  J Magn Reson Imaging       Date:  2013-02-28       Impact factor: 4.813

Review 10.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.