Literature DB >> 19161134

Mechanically adjustable coil array for wrist MRI.

J A Nordmeyer-Massner1, N De Zanche, K P Pruessmann.   

Abstract

In this work, the concept of mechanically adjustable MR receiver coil arrays is proposed and implemented for the specific case of human wrist imaging. An eight-channel wrist array for proton MRI at 3 Tesla was constructed and evaluated. The array adjusts to the individual anatomy by a mechanism that fits a configuration of flexible coil elements closely around the wrist. With such adjustability, it is challenging to ensure robust electrical behavior and signal-to-noise (SNR) performance. These requirements are met by preamplifier decoupling and a suitable matching strategy based on pi networks that render the coil responses robust against changes in tuning, loading and mutual coupling. The robustness of the resulting SNR yield was studied by varying the effective coil matching over a wide range in a phantom imaging experiment. While SNR variation of up to 25% was observed at the surface of the phantom the SNR was essentially constant in the critical center region. A second SNR study in wrist phantoms of different sizes confirmed the benefits of bringing the coil elements very close, up to 3 mm, to the individual target volume. These findings were supported by initial in vivo imaging, exploiting high-sensitivity detection for highly resolved structural imaging. Copyright 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19161134     DOI: 10.1002/mrm.21868

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Size-adaptable "Trellis" structure for tailored MRI coil arrays.

Authors:  Bei Zhang; Ryan Brown; Martijn Cloos; Riccardo Lattanzi; Daniel Sodickson; Graham Wiggins
Journal:  Magn Reson Med       Date:  2018-12-21       Impact factor: 4.668

2.  MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T.

Authors:  Felix P Kuhn; Georg Spinner; Filippo Del Grande; Michael Wyss; Marco Piccirelli; Stefan Erni; Pascal Pfister; Michael Ho; Bert-Ram Sah; Lukas Filli; Dominik A Ettlin; Luigi M Gallo; Gustav Andreisek; Andrei Manoliu
Journal:  Dentomaxillofac Radiol       Date:  2016-12-18       Impact factor: 2.419

3.  Parallel imaging performance investigation of an 8-channel common-mode differential-mode (CMDM) planar array for 7T MRI.

Authors:  Xiaoqing Hu; Xiao Chen; Xin Liu; Hairong Zheng; Ye Li; Xiaoliang Zhang
Journal:  Quant Imaging Med Surg       Date:  2014-02

4.  Application of Adaptive Image Receive Coil Technology for Whole-Brain Imaging.

Authors:  Petrice M Cogswell; Joshua D Trzasko; Erin M Gray; Norbert G Campeau; Phillip J Rossman; Daehun Kang; Fraser Robb; Robert S Stormont; Scott A Lindsay; Matt A Bernstein; Kiaran P McGee; John Huston
Journal:  AJR Am J Roentgenol       Date:  2020-11-25       Impact factor: 3.959

5.  A semiflexible 64-channel receive-only phased array for pediatric body MRI at 3T.

Authors:  Tao Zhang; Thomas Grafendorfer; Joseph Y Cheng; Peigang Ning; Bob Rainey; Mark Giancola; Sarah Ortman; Fraser J Robb; Paul D Calderon; Brian A Hargreaves; Michael Lustig; Greig C Scott; John M Pauly; Shreyas S Vasanawala
Journal:  Magn Reson Med       Date:  2015-09-29       Impact factor: 4.668

6.  A 32-Channel Head Coil Array with Circularly Symmetric Geometry for Accelerated Human Brain Imaging.

Authors:  Ying-Hua Chu; Yi-Cheng Hsu; Boris Keil; Wen-Jui Kuo; Fa-Hsuan Lin
Journal:  PLoS One       Date:  2016-02-24       Impact factor: 3.240

7.  A flexible MRI coil based on a cable conductor and applied to knee imaging.

Authors:  Bili Wang; Syed S Siddiq; Jerzy Walczyk; Mary Bruno; Iman Khodarahmi; Inge M Brinkmann; Robert Rehner; Karthik Lakshmanan; Jan Fritz; Ryan Brown
Journal:  Sci Rep       Date:  2022-09-02       Impact factor: 4.996

8.  Bayesian intravoxel incoherent motion parameter mapping in the human heart.

Authors:  Georg R Spinner; Constantin von Deuster; Kerem C Tezcan; Christian T Stoeck; Sebastian Kozerke
Journal:  J Cardiovasc Magn Reson       Date:  2017-11-06       Impact factor: 5.364

9.  Flexible 23-channel coil array for high-resolution magnetic resonance imaging at 3 Tesla.

Authors:  Roberta Frass-Kriegl; Lucia Isabel Navarro de Lara; Michael Pichler; Jürgen Sieg; Ewald Moser; Christian Windischberger; Elmar Laistler
Journal:  PLoS One       Date:  2018-11-01       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.