Abstract
BACKGROUND: Fixed prosthodontics require an accurate impression for the teeth and the area to be restored for the laboratory to fabricate the desired restoration without mistakes. This study evaluated the quality of impressions received by private laboratories for the fabrication of fixed prosthesis by describing the frequency of clinically detectable errors and by analyzing association between the various factors involved.Entities:
Keywords: Fixed prosthesis; Impressions; Laboratories; Quality; Yemen
Mesh:
Substances:
Year: 2020 PMID: 33148226 PMCID: PMC7640478 DOI: 10.1186/s12903-020-01294-1
Source DB: PubMed Journal: BMC Oral Health ISSN: 1472-6831 Impact factor: 2.757
Errors of impressions
| F | % | |
|---|---|---|
| Voids in finish line | 72 | 43.6 |
| Bubbles in finish line | 114 | 69.1 |
| Tear in finish line | 29 | 17.6 |
| Tissue over finish line | 19 | 11.5 |
| Pull or fold in finish line | 54 | 32.7 |
| Inadequate gingival retraction | 147 | 89.1 |
| Voids in preparation area | 45 | 28.3 |
| Bubbles in preparation area | 54 | 34.0 |
| Tray show through preparation area | 21 | 13.2 |
| Poor details | 149 | 6.3 |
| Inadequate retention of material to tray | 8 | 4.8 |
| 86 | 52.1 | |
Fig. 1Examples of the errors that found in study sample; a Finish line errors; tissue over finish line, b Finish line errors; tears in finish line, c Errors in preparation area; voids, d Errors in silicone impression technique; lack of wash materials in finish line
Association between the type of errors and types of impression material
| Impression material | p-value | ||||||
|---|---|---|---|---|---|---|---|
| Alginate | Addition silicone | Condensation silicone | |||||
| F | % | F | % | F | % | ||
| Yes | 59 | 81.9 | 3 | 4.2 | 10 | 13.9 | 0.000 |
| No | 25 | 26.9 | 31 | 33.3 | 37 | 39.8 | |
| Yes | 70 | 61.4 | 13 | 11.4 | 31 | 27.2 | 0.000 |
| No | 14 | 27.5 | 21 | 41.2 | 16 | 31.4 | |
| Yes | 16 | 55.2 | 5 | 17.2 | 8 | 27.6 | 0.848 |
| No | 68 | 50.0 | 29 | 21.3 | 39 | 28.7 | |
| Yes | 6 | 31.6 | 5 | 26.3 | 8 | 42.1 | 0.191 |
| No | 78 | 53.4 | 29 | 19.9 | 39 | 26.7 | |
| Yes | 22 | 40.7 | 9 | 16.7 | 23 | 42.6 | 0.020 |
| No | 62 | 55.9 | 25 | 22.5 | 24 | 21.6 | |
| Adequate | 2 | 14.3 | 11 | 78.6 | 1 | 7.1 | 0.000 |
| Inadequate | 82 | 55.8 | 20 | 13.6 | 45 | 30.6 | |
| 0 | 0.0 | 3 | 75.0 | 1 | 25.0 | ||
| Yes | 84 | 55.3 | 24 | 15.8 | 44 | 28.9 | 0.000 |
| No | 0 | 0.0 | 10 | 76.9 | 3 | 23.1 | |
| Adequate | 78 | 49.7 | 34 | 21.7 | 45 | 28.7 | 0.308 |
| Inadequate | 6 | 75.0 | 0 | 0.0 | 2 | 25.0 | |
| Yes | 31 | 67.4 | 4 | 8.7 | 11 | 23.9 | 0.016 |
| No | 53 | 44.5 | 30 | 25.2 | 36 | 30.3 | |
| Yes | 35 | 61.4 | 7 | 12.3 | 15 | 26.3 | 0.084 |
| No | 49 | 45.4 | 27 | 25.0 | 32 | 29.6 | |
| Yes | 20 | 95.2 | 0 | 0.0 | 1 | 4.8 | 0.000 |
| No | 64 | 44.4 | 34 | 23.6 | 46 | 31.9 | |
| Yes | 5 | 50.0 | 1 | 10.0 | 4 | 40.0 | 0.633 |
| No | 79 | 51.0 | 33 | 21.3 | 43 | 27.7 | |
| Yes | 58 | 65.2 | 9 | 10.1 | 22 | 24.7 | 0.000 |
| No | 26 | 34.2 | 25 | 32.9 | 25 | 32.9 | |
| Yes | 69 | 80.2 | 11 | 12.8 | 6 | 7.0 | 0.000 |
| No | 15 | 19.0 | 23 | 29.1 | 41 | 51.9 | |
Errors of silicone impression technique
| Type of errors of silicone impression technique | F | % |
|---|---|---|
| Total impressions with errors | 59 | 72.8 |
| Inadequate impression materials mixing | 22 | 27.2 |
| Stepped impression | 4 | 4.9 |
| Lack of wash materials in finish line area | 13 | 16 |
| Heavy bodied materials exposure through wash material | 56 | 69.1 |
| Inadequate union of materials | 0 | 0.0 |
| Lack of polymerization | 0 | 0.0 |