Literature DB >> 8809262

Comparison of the dimensional accuracy of one- and two-step techniques with the use of putty/wash addition silicone impression materials.

B Idris1, F Houston, N Claffey.   

Abstract

This study compared the putty/wash one-step and two-step techniques for making addition silicone impressions. For each technique 15 impressions were made of a stainless steel base to which three tapered posts were attached. Stone models were made of all impressions. The results indicated that the interabutment distances increased slightly compared with the stainless steel model for both techniques, but the differences between techniques were not considered to be clinically important. The intraabutment measurements for the abutment without undercut increased, whereas abutments with undercuts decreased. These variations from the stainless steel model were also clinically insignificant.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8809262     DOI: 10.1016/s0022-3913(05)80358-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  13 in total

1.  Accuracy of digital and conventional impression techniques and workflow.

Authors:  Paul Seelbach; Cora Brueckel; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2012-10-21       Impact factor: 3.573

2.  In vivo Study of the Accuracy of Dual-arch Impressions.

Authors:  Luciana Martinelli Santayana de Lima; Gilberto Antonio Borges; Luiz Henrique Burnett Junior; Ana Maria Spohr
Journal:  J Int Oral Health       Date:  2014-06-26

3.  A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material.

Authors:  Smita Sara Manoj; K P Cherian; Vidya Chitre; Meena Aras
Journal:  J Indian Prosthodont Soc       Date:  2013-02-06

4.  Evaluation of dimensional stability and accuracy of autoclavable polyvinyl siloxane impression material.

Authors:  Subash M Reddy; D Vijitha; S Karthikeyan; R Balasubramanian; A Satish
Journal:  J Indian Prosthodont Soc       Date:  2012-08-07

5.  Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study.

Authors:  Sreeramulu Basapogu; Ajai Pilla; Suman Pathipaka
Journal:  J Clin Diagn Res       Date:  2016-02-01

6.  Accuracy of Single-Step versus 2-Step Double-Mix Impression Technique.

Authors:  Eduardo Batista Franco; Leonardo Fernandes da Cunha; Francyle Simões Herrera; Ana Raquel Benetti
Journal:  ISRN Dent       Date:  2011-07-25

7.  A Comparison of Accuracy of Matrix Impression System with Putty Reline Technique and Multiple Mix Technique: An In Vitro Study.

Authors:  M Praveen Kumar; Suneel G Patil; Bhandari Dheeraj; Keshav Reddy; Dinker Goel; Gopi Krishna
Journal:  J Int Oral Health       Date:  2015-06

8.  Accuracy of Multiple Pour Cast from Various Elastomer Impression Methods.

Authors:  Satheesh B Haralur; Majed Saad Toman; Abdullah Ali Al-Shahrani; Abdullah Ali Al-Qarni
Journal:  Int J Dent       Date:  2016-12-14

9.  The effect of repeated immersion of gypsum cast in sodium hypochlorite and glutaraldehyde on its physical properties: An in vitro study.

Authors:  Rachuri Narendra Kumar; Subash M Reddy; Suma Karthigeyan; Rachuri Punithavathy; K S Karthik; R Manikandan
Journal:  J Pharm Bioallied Sci       Date:  2012-08

10.  Accuracy of different putty-wash impression techniques with various spacer thickness.

Authors:  Anshul Chugh; Aman Arora; Vijay Pratap Singh
Journal:  Int J Clin Pediatr Dent       Date:  2012-02-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.