Literature DB >> 17378455

The effect of a range of disinfectants on the dimensional accuracy and stability of some impression materials.

D C Jagger1, R W Vowles, L McNally, F Davis, D J O'Sullivan.   

Abstract

Disinfection of dental impressions should be considered as a routine procedure in dental surgeries and dental laboratories. Disinfectants can have deleterious effects on some properties of impression materials. The aim of this study was to evaluate the dimensional accuracy and dimensional stability of a model dental stone, reproduced from five commonly used impression materials (Aquasil soft putty/Aquasil Ultra LV; Aquasil Monophase; Aquasil Ultra Heavy; Impregum F and Provil putty/Provil Light CD wash) retained by their adhesives in acrylic resin trays and exposed to three disinfectant solutions (Perform ID; Haz-Tabs and MD 520). Two hundred models were used to investigate the effect of the three disinfectants on the dimensional accuracy of the five impression materials. Five impressions were taken for each impression material for each disinfection treatment group. Measurements were carried out using a High Precision Reflex Microscope. All materials demonstrated a percentage change in dimensions when subjected to no disinfection when compared to the brass master die and all materials demonstrated a percentage change in dimension when subjected to the different disinfection procedures. The results of this study have demonstrated that for all of the materials investigated, the changes in dimensional stability were small in the order of microns. These changes may however be of clinical significance for procedures requiring a high degree of accuracy, for example fixed prosthodontics. The materials respond differently depending on the disinfectant used and it may therefore be appropriate that manufacturers recommend the use of particular disinfectants for their products in order to ensure optimum dimensional accuracy and stability.

Mesh:

Substances:

Year:  2007        PMID: 17378455

Source DB:  PubMed          Journal:  Eur J Prosthodont Restor Dent        ISSN: 0965-7452


  12 in total

1.  [Effect of disinfectant with benzethon chloramine and isopropanol as main active ingredients on the accuracy of dental impression].

Authors:  D Xu; D H Wei; Y C Zhang; P DI; Y Lin
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-12-18

2.  The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materials.

Authors:  Usama Nassar; Carlos Flores-Mir; Giseon Heo; Ysidora Torrealba
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

3.  Comparative evaluation of dimensional stability of impression materials from developing countries and developed countries after disinfection with different immersion disinfectant systems and ultraviolet chamber.

Authors:  Rupandeep Kaur Samra; Shreenivas Vasant Bhide
Journal:  Saudi Dent J       Date:  2017-12-13

4.  Effect of 0.5% glutaraldehyde disinfection on surface wettability of elastomeric impression materials.

Authors:  Sahar AlZain
Journal:  Saudi Dent J       Date:  2018-10-15

Review 5.  Effect of chemical, microwave irradiation, steam autoclave, ultraviolet light radiation, ozone and electrolyzed oxidizing water disinfection on properties of impression materials: A systematic review and meta-analysis study.

Authors:  Sahar AlZain
Journal:  Saudi Dent J       Date:  2019-12-23

6.  The effect of disinfection by spray atomization on dimensional accuracy of condensation silicone impressions.

Authors:  Fariba Saleh Saber; Nader Abolfazli; Maryam Kohsoltani
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2010-12-21

7.  Wettability changes in polyether impression materials subjected to immersion disinfection.

Authors:  Shweta Shetty; Giridhar Kamat; Rajesh Shetty
Journal:  Dent Res J (Isfahan)       Date:  2013-07

8.  Effect of mixing techniques on bacterial attachment and disinfection time of polyether impression material.

Authors:  Umut Guler; Yasemin Budak; Emrah Ruh; Yesim Ocal; Senay Canay; Yakut Akyon
Journal:  Eur J Dent       Date:  2013-09

9.  Evaluation of dimensional accuracy for different complete edentulous impressions immersed in different disinfectant solutions.

Authors:  Hussein Abdelfattah Ismail; Hamada Z Mahross; Suaad Shikho
Journal:  Eur J Dent       Date:  2017 Apr-Jun

10.  Dimensional Stability of a Preliminary Vinyl Polysiloxane Impression Material.

Authors:  Francisco Martins; José Reis; Ignacio Barbero Navarro; Paulo Maurício
Journal:  Dent J (Basel)       Date:  2019-08-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.