| Literature DB >> 32878598 |
Rui Liu1, Qingchen Li2,3,4.
Abstract
BACKGROUND: To observe the changes in ocular biometric measurements after vitrectomy with silicone oil tamponade for rhegmatogenous retinal detachment (RRD) repair.Entities:
Keywords: Myopic shift; Ocular biometric measurement; Rhegmatogenous retinal detachment; Silicone oil tamponade; Vitrectomy
Mesh:
Substances:
Year: 2020 PMID: 32878598 PMCID: PMC7466810 DOI: 10.1186/s12886-020-01627-2
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
The comparison of measurements between preoperative and postoperative
| n (pairs) | Preoperative | Postoperative | Difference (post-pre) | Paired samples t-test | |||||
|---|---|---|---|---|---|---|---|---|---|
| Mean | SD | Mean | SD | Mean | 95% CI | t value | P value* | ||
| AL (mm) | 45 | 24.94 | 1.82 | 25.42 | 2.20 | 0.48 | 0.26, 0.69 | −4.493 | |
| ACD (mm) | 42 | 3.45 | 0.42 | 3.30 | 0.41 | − 0.14 | −0.20, − 0.08 | 4.974 | |
| LT (mm) | 53 | 4.34 | 0.16 | 4.43 | 0.21 | 0.09 | 0.06, 0.12 | −5.564 | |
| LP (mm) | 36 | 5.55 | 0.41 | 5.46 | 0.40 | −0.09 | −0.16, − 0.03 | 2.862 | 0.007 |
| RLP | 28 | 0.22 | 0.01 | 0.22 | 0.02 | −0.01 | −0.01, 0 | 4.458 | |
| LRD (mm) | 28 | 19.52 | 1.82 | 20.17 | 2.36 | 0.65 | 0.32, 0.98 | −4.059 | |
*P values less than 0.05 are represented in bold
AL axial length, ACD anterior chamber depth, LT lens thickness, LP lens position, RLP relative lens position, LRD lens-retina distance
Univariate linear regression between patient characteristics and changes of biometric measurements
| Predictors† | n (pairs) | Age (years) | Duration of silicone oil tamponade (months) | ||||
|---|---|---|---|---|---|---|---|
| β | P value* | r2 | β | P value* | r2 | ||
| △AL (mm) | 45 | −0.291 | 0.052 | 0.085 | −0.078 | 0.610 | 0.006 |
| △ACD (mm) | 42 | 0.260 | 0.097 | 0.067 | 0.001 | 0.997 | < 0.001 |
| △LT (mm) | 53 | −0.120 | 0.391 | 0.14 | 0.817 | 0.668 | |
| △LP (mm) | 36 | 0.249 | 0.144 | 0.062 | 0.234 | 0.170 | 0.055 |
| △RLP | 28 | 0.380 | 0.144 | 0.283 | 0.144 | 0.080 | |
| △LRD (mm) | 28 | −0.439 | 0.193 | −0.148 | 0.453 | 0.022 | |
†△ = “postoperative - preoperative”
*P values less than 0.05 are represented in bold
AL axial length, ACD anterior chamber depth, LT lens thickness, LP lens position, RLP relative lens position, LRD lens-retina distance
Fig. 1Univariate linear regressions between △LRD and biometric measurements. Preoperative AL and LRD are positively correlated with △LRD, while RLP is negatively correlated with △LRD (all P < 0.05). None of preoperative ACD, LT or LP is correlated with △LRD (all P > 0.05), and △AL (P < 0.05) but not △LT or △LP (P > 0.05) is correlated with △LRD
Fig. 2Bland-Altman plots of AL, ACD, LT, LP, RLP and LRD between preoperative and postoperative data. AL, ACD, LP, RLP and LRD (more than 95% cases were included in 95% limits of agreement) but not LT (50/53, 94.3% cases were included in 95% limits of agreement) were in close agreement