Literature DB >> 31182834

Accuracy of intraocular lens calculations based on fellow-eye biometry for phacovitrectomy for macula-off rhegmatogenous retinal detachments.

Abdul R El-Khayat1, Alex J Brent2, Shamfa A M Peart2, Partha R Chaudhuri2.   

Abstract

OBJECTIVES: To determine the accuracy of using fellow-eye biometry for intraocular lens calculations for phacovitrectomy for macula off rhegmatogenous retinal detachments.
METHODS: Retrospective case review of phacovitrectomies for consecutive macula off retinal detachments over 10 years. Optical and/or ultrasound biometry was performed for affected and fellow eyes. Prediction error was determined by calculating the difference between predicted and actual refractive outcomes. Results from fellow- and same-eye biometry were compared.
RESULTS: Forty-two eyes were included. The mean prediction errors for fellow- and same-eye biometry were -0.01 ± 1.09 and -1.22 ± 2.32 dioptres, respectively, indicating a myopic shift for same eye biometry calculations. The mean absolute prediction errors for fellow and same eye biometry were 0.73 ± 0.80 and 1.57 ± 2.08 dioptres, respectively. The difference was statistically significant (P = 0.016).
CONCLUSIONS: When appropriate, intraocular lens calculations using fellow-eye biometry for phacovitrectomy for macula off rhegmatogenous retinal detachments are accurate and better than those from same-eye biometry.

Entities:  

Year:  2019        PMID: 31182834      PMCID: PMC7002476          DOI: 10.1038/s41433-019-0485-0

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  4 in total

1.  Changes in axial length after vitrectomy for rhegmatogenous retinal detachment combined with choroidal detachment.

Authors:  Ji-Peng Li; Jun Xu; Meng Zhao
Journal:  Int J Ophthalmol       Date:  2022-08-18       Impact factor: 1.645

2.  Accuracy of segmented measurement of axial length in ultra-high myopia filled with silicone oil using immersion B-scan ultrasonography.

Authors:  Qing-Hua Yang; Hong-Tao Zhang; Xiao-Qi Li; Bing Chen; Zhao-Hui Li; Yi-Fei Huang; Xin Jin; Ying Zhang; Li-Qiang Wang
Journal:  Int J Ophthalmol       Date:  2022-05-18       Impact factor: 1.645

3.  Changes in ocular biometric measurements after vitrectomy with silicone oil tamponade for rhegmatogenous retinal detachment repair.

Authors:  Rui Liu; Qingchen Li
Journal:  BMC Ophthalmol       Date:  2020-09-02       Impact factor: 2.209

4.  Differences in Axial Length and IOL Power Based on Alternative A-Scan or Fellow-Eye Biometry in Macula-Off Rhegmatogenous Retinal Detachment Eyes.

Authors:  Rui Liu; Hongrong Li; Qingchen Li
Journal:  Ophthalmol Ther       Date:  2021-12-08
  4 in total