Literature DB >> 27770390

Repeatability of ocular biometry with IOLMaster 700 in subjects with clear lens.

Manuel Garza-Leon1, Hugo A Fuentes-de la Fuente2, Ana V García-Treviño2.   

Abstract

PURPOSE: The purpose of the study was to assess the reproducibility of ocular biometry using the IOLMaster-700 in a healthy population.
METHODS: This is a prospective, cross-sectional, observational reproducibility study. Ocular biometry was performed three times on each of 45 studied eyes. Flattest meridian (Kf) and the steepest meridian (Ks), central corneal thickness, axial length, anterior chamber depth, aqueous depth, lens thickness, and white-to-white distances were recorded. Reproducibility was evaluated using the coefficient of variation (CV), the within subject standard deviation, and the intraclass correlation coefficient (ICC).
RESULTS: There was a high reproducibility in all parameters; CV was between 0.3 and 1 %, and the ICC was higher than 0.87 in all measurements.
CONCLUSIONS: IOLMaster-700 showed high reproducibility for ocular biometry.

Keywords:  Axial length; Keratometry; Ocular biometry; Reproducibility; White-to-white distance

Mesh:

Year:  2016        PMID: 27770390     DOI: 10.1007/s10792-016-0380-7

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  30 in total

1.  Choice of analytic approach for eye-specific outcomes: one eye or two?

Authors:  Anna Karakosta; Maria Vassilaki; Sotiris Plainis; Nazik Hag Elfadl; Miltiadis Tsilimbaris; Joanna Moschandreas
Journal:  Am J Ophthalmol       Date:  2011-11-10       Impact factor: 5.258

2.  Surgical management of malignant glaucoma with white cataract in nanophthalmos.

Authors:  Yi-fan Feng; Dan-dan Wang; Yun-e Zhao; Jun-hua Li; Giacomo Savini; Jin-hai Huang
Journal:  J Cataract Refract Surg       Date:  2013-09-07       Impact factor: 3.351

Review 3.  People and eyes: statistical approaches in ophthalmology.

Authors:  I E Murdoch; S S Morris; S N Cousens
Journal:  Br J Ophthalmol       Date:  1998-08       Impact factor: 4.638

4.  [Comparison of two different surgical treatments of presbyopia for hyperopic patients over 55 years old: Presbylasik (Supracor) and Prelex (presbyopic lens exchange)].

Authors:  L Moyal; M Abrieu-Lacaille; S Bonnel; D Sendon; B de Rivoyre; M Berguiga; C Rambaud; F Froussart-Maille; J-C Rigal-Sastourné
Journal:  J Fr Ophtalmol       Date:  2015-04-01       Impact factor: 0.818

5.  Cataract surgery in eyes with nanophthalmos and relative anterior microphthalmos.

Authors:  Kyoung In Jung; Ji Wook Yang; Young Chun Lee; Su-Young Kim
Journal:  Am J Ophthalmol       Date:  2012-02-24       Impact factor: 5.258

6.  White-to-white corneal diameter differences in moderately and highly myopic eyes: partial coherence interferometry versus scanning-slit topography.

Authors:  Raul Martin; Sara Ortiz; Ana Rio-Cristobal
Journal:  J Cataract Refract Surg       Date:  2013-02-12       Impact factor: 3.351

Review 7.  Refractive lens exchange.

Authors:  Jorge L Alio; Andrzej Grzybowski; Amr El Aswad; Dorota Romaniuk
Journal:  Surv Ophthalmol       Date:  2014-05-09       Impact factor: 6.048

8.  Objective vs subjective vault measurement after myopic implantable collamer lens implantation.

Authors:  José F Alfonso; Carlos Lisa; Ana Palacios; Paulo Fernandes; José M González-Méijome; Robert Montés-Micó
Journal:  Am J Ophthalmol       Date:  2009-03-14       Impact factor: 5.258

9.  Long-term results of clear lens extraction combined with piggyback intraocular lens implantation to correct high hyperopia.

Authors:  Xia Hua; Xiao-Yong Yuan; Hui Song; Xin Tang
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

10.  Comparison of anterior segment measurements obtained by three different devices in healthy eyes.

Authors:  Carmen Lopez de la Fuente; Ana Sanchez-Cano; Francisco Segura; Isabel Pinilla
Journal:  Biomed Res Int       Date:  2014-06-02       Impact factor: 3.411

View more
  7 in total

1.  Mechanism of accommodation assessed by change in precisely registered ocular images associated with concurrent change in auto-refraction.

Authors:  Andrzej Grzybowski; Ronald A Schachar; Magdalena Gaca-Wysocka; Ira H Schachar; Farhad Kamangar; Barbara K Pierscionek
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-11-16       Impact factor: 3.117

2.  Change in axial length after vitrectomy with silicone oil tamponade for rhegmatogenous retinal detachment.

Authors:  Jiemei Shi; Kaicheng Wu; Huiming Wen; Jiaojiao Wei; Yuan Zong; Jian Yu; Haohao Zhu; Chunhui Jiang
Journal:  BMC Ophthalmol       Date:  2022-06-08       Impact factor: 2.086

3.  Precision of a new ocular biometer in eyes with cataract using swept source optical coherence tomography combined with Placido-disk corneal topography.

Authors:  Wenwen Wang; Yaxin Miao; Giacomo Savini; Colm McAlinden; Hao Chen; Qingjie Hu; Qinmei Wang; Jinhai Huang
Journal:  Sci Rep       Date:  2017-10-23       Impact factor: 4.379

4.  Effect of orthokeratology on precision and agreement assessment of a new swept-source optical coherence tomography biometer.

Authors:  Bao Shu; Fangjun Bao; Giacomo Savini; Weicong Lu; Ruixue Tu; Haisi Chen; Benhao Song; Qinmei Wang; Jinhai Huang
Journal:  Eye Vis (Lond)       Date:  2020-03-02

5.  Comparison of Simulated and True Keratometry Measurements Using Swept-Source Optical Coherence Tomography and Dual Scheimpflug-Placido Imaging.

Authors:  Elizabeth A Urias; Efstathia Polychronopoulou; Rahul T Pandit
Journal:  J Ophthalmol       Date:  2021-09-16       Impact factor: 1.909

6.  The accuracy of the axial length and axial length/corneal radius ratio for myopia assessment among Chinese children.

Authors:  Jingfeng Mu; Dan Zeng; Jingjie Fan; Meizhou Liu; Haoxi Zhong; Xinyi Shuai; Shaochong Zhang
Journal:  Front Pediatr       Date:  2022-09-06       Impact factor: 3.569

7.  Changes in ocular biometric measurements after vitrectomy with silicone oil tamponade for rhegmatogenous retinal detachment repair.

Authors:  Rui Liu; Qingchen Li
Journal:  BMC Ophthalmol       Date:  2020-09-02       Impact factor: 2.209

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.