Does Computer-assisted Surgery Improve Lag Screw Placement During Cephalomedullary Nailing of Intertrochanteric Hip Fractures?

Mitchell Kuhl1, Claudia Beimel2.   

Abstract

BACKGROUND: Computer-assisted surgery (CAS) techniques have been shown to improve implant placement and reduce the radiation time during cephalomedullary nailing in cadaveric and pilot clinical studies of intertrochanteric hip fractures. However, clinical comparisons of CAS and conventional techniques are lacking. It is unclear whether CAS offers clear advantages in terms of radiation time, operative time, and accuracy of lag-screw placement in patients undergoing surgery for intertrochanteric hip fractures and whether any potential difference in accuracy is associated with a change in the risk of lag-screw cut-out postoperatively. QUESTIONS/PURPOSES: In patients undergoing cephalomedullary nailing for intertrochanteric hip fractures compared with the conventional technique, we asked: (1) Is the CAS technique associated with a decrease in tip-apex distance (TAD), with less variation and fewer outliers at the standard (25 mm) and lower (15 mm) TAD thresholds? (2) Is the CAS technique associated with a decrease in radiation and operative time? (3) If the CAS technique results in a decrease in TAD, is this decrease associated with a decrease in lag screw cut-out postoperatively?
METHODS: Between Oct 2007 and June 2015, 964 stable and unstable intertrochanteric hip fractures were treated surgically at our institution. Of these, 23% (225 of 964) were isolated, acute intertrochanteric hip fractures managed by a single surgeon. Ninety-five percent (213 of 225) of hip fractures were surgically treated with the same cephalomedullary nail based on the general indications of displaced fractures, poor bone quality, and medical complexity. This same surgeon used a sliding hip screw device in the remaining 5% (12 of 225) of hip fractures for the treatment of nondisplaced and minimally displaced fractures in younger patients with fewer medical comorbidities and good bone quality. Between October 2007 and August 2011, all procedures were performed with conventional lag screw placement (n = 110), and between September 2011 and June 2015, all procedures were performed with CAS (n = 103) for lag screw placement. Postoperative radiographs were missing or unavailable for TAD analysis for 3% (3 of 110) of the conventional technique group and 6% (6 of 103) of the CAS group, so these patients were excluded. The remaining 97% (107 of 110) of conventional procedures and 94% (97 of 103) of CAS procedures were included in the TAD, radiation time, and operative time analysis. For the evaluation of cut-out postoperatively, 24% (26 of 107) of conventional patients and 25% (24 of 97) of CAS patients were excluded due to mortality and/or loss to follow-up at a minimum of 1 year. The remaining 76% (81 of 107) of conventional patients and 75% (73 of 97) of CAS patients were included in the cut-out analysis. A retrospective chart review was performed to obtain the data and then compare TAD, radiation time, operative time, and cut-out between the two cohorts.
RESULTS: The median TAD for the CAS procedures was lower than the median TAD for the conventional procedures (median 13 mm versus median 16 mm, median difference 3 mm; p < 0.001 power for difference = 85%). In addition, the TAD variation was also less for the CAS procedures compared with the conventional procedures (interquartile range [IQR] 4 mm versus IQR 9 mm, IQR difference 5 mm; p < 0.001, power for difference = 98%). A TAD greater than 25 mm was found in 1% (1 of 97) of the CAS procedures and 12% (13 of 107) of the conventional procedures. A difference between the proportions could be detected indicating a lesser chance of a TAD > 25 mm in the CAS cohort (odds ratio = 0.075 [95% confidence interval 0.010 to 0.587]; p = 0.002, power for difference 90%). A TAD > 15 mm was found in 23% (22 of 97) of the CAS procedures and 56% (60 of 107) of the conventional procedures, also indicating a lesser chance of a TAD > 15 mm in the CAS cohort (OR = 0.230 [95% CI 0.125 to 0.423], relative risk for TAD > 15 mm = 0.404 [95% CI 0.270 to 0.606]; p < 0.001, power for difference > 99%). The median radiation time for the CAS cohort was lower than the median radiation time for the conventional cohort (median 1.4 minutes versus median 1.7 minutes, median difference 0.3 minutes; p = 0.002, power for difference = 81%). No difference in median total operating time was found for the CAS procedures compared with the conventional procedures (median 36 minutes versus median 38 minutes, median difference 2 minutes; p = 0.227, power for difference = 18%, power for equivalency = 93%). There was no difference in cut-out noted with the use of the CAS compared with the conventional technique with the numbers available. Based on the current results, the upper 95% probability for a cutout complication ranges from 0% to 5% in the CAS cohort versus 0% to 9% in the conventional cohort (difference of upper 95% CI = 4%).
CONCLUSION: CAS use is associated with a decrease in median TAD with less variation and fewer outliers during cephalomedullary nailing. Compared with the conventional technique, fewer outliers were noted with the CAS at the standard TAD threshold of 25 mm and a lower TAD threshold of 15 mm. Additional research is needed to determine the association of TAD variation and outliers on cut-out and to determine if there is any clinical value to the decrease in TAD variation and outliers noted here. The patient and surgical team are exposed to less radiation with the CAS compared with the conventional technique, but this difference is small and it is unclear if this benefit justifies CAS use. Incorporating CAS into the cephalomedullary nailing procedure is not associated with a change in operative time, so there are no costs or risks associated with increased operative time. More procedures would be needed to provide adequate power to better analyze the risk of lag screw cut-out, allowing a more complete understanding of the value of this technology compared with its cost. LEVEL OF EVIDENCE: Level III, therapeutic study.

Entities:  

Mesh:

Year:  2020        PMID: 32496321      PMCID: PMC7431259          DOI: 10.1097/CORR.0000000000001306

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.755


  20 in total

Review 1.  Occupational radiation exposure to the surgeon.

Authors:  Gordon Singer
Journal:  J Am Acad Orthop Surg       Date:  2005 Jan-Feb       Impact factor: 3.020

2.  Measuring tip-apex distance using a picture archiving and communication system (PACS).

Authors:  Luke J Johnson; Marcus R Cope; Shahram Shahrokhi; Peter Tamblyn
Journal:  Injury       Date:  2008-06-09       Impact factor: 2.586

3.  Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip.

Authors:  M R Baumgaertner; B D Solberg
Journal:  J Bone Joint Surg Br       Date:  1997-11

4.  Prolonged operative duration is associated with complications: a systematic review and meta-analysis.

Authors:  Hang Cheng; Jeffrey W Clymer; Brian Po-Han Chen; Behnam Sadeghirad; Nicole C Ferko; Chris G Cameron; Piet Hinoul
Journal:  J Surg Res       Date:  2018-04-24       Impact factor: 2.192

5.  Reliability of predictors for screw cutout in intertrochanteric hip fractures.

Authors:  Kirstin De Bruijn; Dennis den Hartog; Wim Tuinebreijer; Gert Roukema
Journal:  J Bone Joint Surg Am       Date:  2012-07-18       Impact factor: 5.284

6.  Predictive factors for cutting-out in femoral intramedullary nailing.

Authors:  Antonio Lobo-Escolar; Eduardo Joven; Daniel Iglesias; Antonio Herrera
Journal:  Injury       Date:  2010-09-15       Impact factor: 2.586

7.  Nail or plate fixation of intertrochanteric hip fractures: changing pattern of practice. A review of the American Board of Orthopaedic Surgery Database.

Authors:  Jeffrey O Anglen; James N Weinstein
Journal:  J Bone Joint Surg Am       Date:  2008-04       Impact factor: 5.284

8.  Enhanced cephalomedullary nail lag screw placement and intraoperative tip-apex distance measurement with a novel computer assisted surgery system.

Authors:  Mitchell Kuhl; Claudia Beimel
Journal:  Injury       Date:  2016-07-19       Impact factor: 2.586

9.  Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures.

Authors:  Jeffrey A Geller; Comron Saifi; Todd A Morrison; William Macaulay
Journal:  Int Orthop       Date:  2009-07-18       Impact factor: 3.075

10.  Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients.

Authors:  Kuang-Kai Hsueh; Chi-Kuang Fang; Chuan-Mu Chen; Yu-Ping Su; Heng-Fei Wu; Fang-Yao Chiu
Journal:  Int Orthop       Date:  2009-09-26       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.