Literature DB >> 18539280

Measuring tip-apex distance using a picture archiving and communication system (PACS).

Luke J Johnson1, Marcus R Cope, Shahram Shahrokhi, Peter Tamblyn.   

Abstract

BACKGROUND: The sliding hip screw is currently the most frequently used prosthesis used to fix trochanteric fractures of the hip. The 'tip-apex distance' (TAD) has been found to be predictive of hardware failure, with a larger TAD being associated with an increasing risk of 'cut-out'. Previous studies have either used 'hard-copy' radiographs and geometrical aids or a mixture of scanned hard-copy images and extra software to measure TAD. The current study describes a new method of tip-apex distance estimation using an entirely digital picture archiving and communication system (PACS).
MATERIALS AND METHODS: Ten radiographs were measured for TAD by four surgeons of differing experience using the described measurement protocol, at two different time points (4 weeks apart). The results were then subjected to two-tailed t-tests to determine if they differed significantly.
RESULTS: No tests attained significance (i.e. no statistical difference existed between the observers' measurements and no difference existed over time from a single observer's results).
CONCLUSION: This study shows that TAD can be easily, accurately and, importantly, reproducibly measured using an entirely digitally based image capture and archiving system. The ease with which the measurements and calculations can be made will facilitate orthopaedic practitioners and trauma units in their auditing activities, and allows for quick TAD estimation in the 'X-ray meeting' environment.

Entities:  

Mesh:

Year:  2008        PMID: 18539280     DOI: 10.1016/j.injury.2007.12.019

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  20 in total

1.  To what degree is digital imaging reliable? Validation of femoral neck shaft angle measurement in the era of picture archiving and communication systems.

Authors:  J D Wilson; W Eardley; S Odak; A Jennings
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

2.  Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures.

Authors:  Richard Stern; Anne Lübbeke; Domizio Suva; Hermes Miozzari; Pierre Hoffmeyer
Journal:  Int Orthop       Date:  2011-03-10       Impact factor: 3.075

3.  Can TAD and CalTAD predict cut-out after extra-medullary fixation with new generation devices of proximal femoral fractures? A retrospective study.

Authors:  Gaetano Caruso; Mattia Andreotti; Carlotta Pari; Francesco Soldati; Alessandro Gildone; Vincenzo Lorusso; Leo Massari
Journal:  J Clin Orthop Trauma       Date:  2016-09-29

4.  Mismatch of short straight proximal femur nails with anterior bow of femur in Indian population- A radiological and functional analysis.

Authors:  Kaustav Mukherjee; Tarun Prashanth K R; Thirunthaiyan M R; Dorai Kumar R
Journal:  J Orthop       Date:  2022-01-29

5.  Minimally Trained Analysts Can Perform Fast, Objective Assessment of Orthopedic Technical Skill from Fluoroscopic Images.

Authors:  Dominik D Mattioli; Geb W Thomas; Steven A Long; Marcus Tatum; Donald D Anderson
Journal:  IISE Trans Healthc Syst Eng       Date:  2022-02-28

6.  Integrating various common indexes of bony alignment in femoral supracondyle.

Authors:  Chi-Chuan Wu
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-12-01

7.  Assessing Wire Navigation Performance in the Operating Room.

Authors:  Leah K Taylor; Geb W Thomas; Matthew D Karam; Clarence D Kreiter; Donald D Anderson
Journal:  J Surg Educ       Date:  2016-05-12       Impact factor: 2.891

8.  Developing an objective assessment of surgical performance from operating room video and surgical imagery.

Authors:  Leah K Taylor; Geb W Thomas; Matthew D Karam; Clarence D Kreiter; Donald D Anderson
Journal:  IISE Trans Healthc Syst Eng       Date:  2018-02-08

9.  Surgical Skill Can be Objectively Measured From Fluoroscopic Images Using a Novel Image-based Decision Error Analysis (IDEA) Score.

Authors:  Steven Long; Geb W Thomas; Matthew D Karam; J Lawrence Marsh; Donald D Anderson
Journal:  Clin Orthop Relat Res       Date:  2021-06-01       Impact factor: 4.755

10.  A review of tip apex distance in dynamic hip screw fixation of osteoporotic hip fractures.

Authors:  Imran Haruna Abdulkareem
Journal:  Niger Med J       Date:  2012-10
View more