Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip.

M R Baumgaertner1, B D Solberg.   

Abstract

We compared the results of the surgical treatment of trochanteric hip fractures before and after surgeons had been introduced to the tip-apex distance (TAD) as a method of evaluating screw position. There were 198 fractures evaluated retrospectively and 118 after instruction. The TAD is the sum of the distance from the tip of the screw to the apex of the femoral head on anteroposterior and lateral views. This decreased from a mean of 25 mm in the control group to 20 mm in the study group (p = 0.0001). The number of mechanical failures by cut-out of the screw from the head decreased from 16 (8%) in the control group at a mean of 13 months to none in the study group at a mean of eight months (p = 0.0015). There were significantly fewer poor reductions in the study group. Our study confirms the importance of good surgical technique in the treatment of trochanteric fractures and supports the concept of the TAD as a clinically useful way of describing the position of the screw.

Entities:  

Mesh:

Year:  1997        PMID: 9393914     DOI: 10.1302/0301-620x.79b6.7949

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  74 in total

1.  Is the rotation of the femoral head a potential initiation for cutting out? A theoretical and experimental approach.

Authors:  Andreas Lenich; Samuel Bachmeier; Lukas Prantl; Michael Nerlich; Jochen Hammer; Edgar Mayr; Amir Andreas Al-Munajjed; Bernd Füchtmeier
Journal:  BMC Musculoskelet Disord       Date:  2011-04-22       Impact factor: 2.362

2.  [Navigated osteosynthesis of the proximal femur. An experimental study].

Authors:  T Hüfner; M Kfuri; D Kendoff; M Richter; J Geerling; C Krettek
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

Review 3.  [Biomechanics of implant augmentation].

Authors:  M Windolf
Journal:  Unfallchirurg       Date:  2015-09       Impact factor: 1.000

Review 4.  Fixation principles in metaphyseal bone--a patent based review.

Authors:  R Curtis; J Goldhahn; R Schwyn; P Regazzoni; N Suhm
Journal:  Osteoporos Int       Date:  2004-11-03       Impact factor: 4.507

5.  Internal fixation of femoral neck fractures with posterior comminution: a biomechanical comparison of DHS® and Intertan nail®.

Authors:  Martin Rupprecht; Lars Grossterlinden; Kai Sellenschloh; Michael Hoffmann; Klaus Püschel; Michael Morlock; Johannes M Rueger; Wolfgang Lehmann
Journal:  Int Orthop       Date:  2011-02-01       Impact factor: 3.075

6.  Fixation of basicervical and related fractures.

Authors:  Elsayed Ibraheem Elsayed Massoud
Journal:  Int Orthop       Date:  2009-05-28       Impact factor: 3.075

7.  Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures.

Authors:  Richard Stern; Anne Lübbeke; Domizio Suva; Hermes Miozzari; Pierre Hoffmeyer
Journal:  Int Orthop       Date:  2011-03-10       Impact factor: 3.075

8.  Is helical blade superior to screw design in terms of cut-out rate for elderly trochanteric fractures? A meta-analysis of randomized controlled trials.

Authors:  Xiao Huang; Frankie Leung; Ming Liu; Long Chen; Zhao Xu; Zhou Xiang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-02-21

Review 9.  Is rotation the mode of failure in pertrochanteric fractures fixed with nails? Theoretical approach and illustrative cases.

Authors:  C Kokoroghiannis; D Vasilakos; K Zisis; G Dimitriou; E Pappa; D Evangelopoulos
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-09-20

10.  A Vision for Using Simulation & Virtual Coaching to Improve the Community Practice of Orthopedic Trauma Surgery.

Authors:  Geb W Thomas; Steven Long; Marcus Tatum; Timothy Kowalewski; Dominik Mattioli; J Lawrence Marsh; Heather R Kowalski; Matthew D Karam; Joan E Bechtold; Donald D Anderson
Journal:  Iowa Orthop J       Date:  2020