Comparison of stress induced in mandible around an implant-supported overdenture with locator attachment and telescopic crowns - a finite element analysis.

Meer Rownaq Ali Abbasi1, Dileep Nag Vinnakota1, Vijaya Sankar1, Rekhalakshmi Kamatham2.   

Abstract

INTRODUCTION: One of the principle factors for the success of implant supported/retained overdentures (IOs) is the manner in which the stresses are transferred to the surrounding bone. Hence, the aim of the present study is to compare the stress induced in the mandible around IOs, using two different attachment systems, locator and telescopic.
METHODS: 3D finite element models were prepared using Pro/ENGINEER or PTC Creo to simulate 4 clinical situations: IOs using two different attachment systems, locator and telescopic, with and without splinting. A vertical compressive load of 35N was directed toward the central fossa in the molar region of each overdenture. Non-linear static contact analysis was carried out to determine the stress distribution in various components of IOs. Then, the models were analyzed by a finite element program ABAQUS, and displayed using Von Mises stress patterns.
RESULTS: The contact stress values developed on the implant and attachment components were lower with locator attachment, in both splinted and non-splinted models. On the other hand, the stress distribution to the cortical bone was more with non-splinted/splinted locator attachments (3.73/4.12 Mega Pascals) when compared to the non-splinted/splinted telescopic attachments (2.66/3.7 Mega Pascals). The stresses in all the components of overdenture were greater with the splinted model compared to non-splinted, in both the attachment systems.
CONCLUSION: The locator attachment might demonstrate superior clinical performance, as the stresses on implant and attachment components were less compared to telescopic. Non-splinted model showed better results in both the attachment types.

Entities:  

Keywords:  attachment; locator; overdenture; stress; telescopic

Year:  2020        PMID: 32478325      PMCID: PMC7243882          DOI: 10.15386/mpr-1312

Source DB:  PubMed          Journal:  Med Pharm Rep        ISSN: 2602-0807


Introduction

Edentulism is a major perpetuating problem in developing countries [1,2]. The consequence of edentulism is bone resorption, which is ten times greater during the first year than in the following years, with mandible experiencing four times greater bone loss than the maxilla [3-5]. Hence, mandibular complete dentures are specifically focused in the literature [6-8]. It was demonstrated, in a study, that 50% of conventional mandibular complete denture wearers displayed problems with retention and stability [6]. Moreover, long term usage of complete dentures further resorbs the bone [4,5,9,10], in turn compromising the treatment outcome. An overdenture employing either natural tooth abutments or implants is an effective alternative treatment modality for the rehabilitation of edentulous patients [10,11]. Studies have indicated a greater probability of treatment success with the use of implants [12,13]. There has been a deceleration in the rate of resorption to 25% and subsequent increase in the alveolar bone height with occlusal load [14,15]. Hence, implant supported/retained overdentures (IOs) have been advocated in the literature as a means of preserving the structures associated with mandibular denture support, in turn augmenting retention, stability and extending the longevity of the prostheses [11-25]. Various types of attachments used with IOs are ball, bar, magnetic, telescopic and locator attachments [26-32]. The mode of retention of these attachments could be frictional, mechanical, both frictional and mechanical or magnetic. The selection of attachment system depends on the amount of retention needed, available inter arch space, manual dexterities of the patient and skills of the dentist [26,27]. Of all, locator and telescopic attachments for IOs have got wide range of acceptance these days [33-42]. The locator attachment with its low profile design is considered as an alternative to the ball attachment, especially when the interarch distance is inadequate, due to its small dimensions and when patients experience problems with rapid wearing of ball abutment components [33-37]. In addition to this it has a self-locating design, which allows the patients to seat the denture easily without the need for accurate alignment of the attachment component in a repeatable path of insertion. Its dual retention is another characteristic feature that provides a greater retention surface area [36,37]. Studies have shown that locator attachment shows superior clinical results compared to ball and bar attachments, with respect to prosthetic complications and maintenance of oral functions [33,35]. Locator attachment is unique in having an inbuilt angulation compensation up to 40° [33-37]. Thus, this attachment is reported to be associated with a more favorable force distribution and magnitude. An overdenture with telescopic attachment is a prosthesis that consists of a primary coping that is cemented to the abutments in a patient’s mouth and a secondary coping that is attached to the prosthesis and fits on the primary coping [38]. Telescopic crowns, are also known as double crowns, crown and sleeve copings. These have been found to provide better force distribution due to the circumferential relation of the outer crown to the abutment [38,39]. This makes axial transfer of occlusal load that produce less rotational torque on the abutment by improving the crown root ratio, thus preserving the tooth and alveolar bone. Double crowns also provide horizontal stabilization as a result of the cone-shaped wall structure and stabilize prostheses against lateral dislocation forces [41]. Comparative studies of telescopic attachments with bar attachment observed superior results with telescopic [38,41]. In spite of the prospective and maintenance studies on locator attachment and telescopic crowns individually, there is no reported study that compared these two. Hence, the present study is planned to evaluate and compare the stress distribution in the bone around mandibular IOs with locator and telescopic attachments using 3 dimensional finite element analysis (3D FEA).

Materials and methods

The process employed in the present study can be arbitrarily divided into three phases: ➢ Geometrical designing of 3D models ➢ Discretization process ➢ Finite element analysis

Geometrical designing of 3D models (Figures 1–6)

➢ Implant models

3D, root-form, threaded, titanium dental implant models with locator or telescopic attachments were designed, based on the accurate dimensions and designs collected from the manufacturer (Noble Biocare, Switzerland). The implant models had 3.7 mm diameter, 13 mm length and internal hex connection. They were simulated as titanium alloy (Ti6Al4V).

➢ Bone model

A D2 bone was modeled and a computer tomography scan of the patient mandible used by plotting key points on the Pro/ENGINEER or PTC Creo software. The edentulous mandible was modeled as 2mm constant cortical bone layer around a cancellous bone core in the interforaminal region, whereas in the remaining areas it was assumed to be homogenous. ➢ Locator attachment and nylon cap (dimensions and material properties as per ZEST Anchors, USA) ➢ Telescopic attachment; primary and secondary copings (dimensions and material properties as per Dentsply, ANKYLOS Syncone/5°, USA) ➢ Overdenture (assumed to be polymethylmethacrylate) ➢ Splinted bar for locator and telescopic attachments The material properties incorporated in the study are represented in Table I. All materials were assumed to be isotropic, homogenous and elastic.
Table I

Material properties incorporated in the study.

S.NoMaterialYoung’s Modulus (GPa)Poisson’s RatioDensity
1Cortical bone137000.3850–1250 HU (D2 bone)
2Cancellous bone13700.3-
3Titanium alloy (Ti6Al4V-implant)1350000.334.43 g/cm3
4Nylon Ring3500.4-
5Cobalt Chromium2180000.338.5 g/cm3
6Mucosa/Gingiva10.37-
7Type 3 Gold850000.315 g/cm3
8Polymethyl Methacrylate (PMMA)24000.351.19 g/cm3

GPa: Gigapascal, g/cm3: Grams per cubic millimeter, HU: Hounsfield unit

All the above models, along with the surrounding alveolar bone and overlying mucosa, were assembled to form a total of 4 clinical simulations. ➢ Implant supported overdenture with non-splinted locator attachment ➢ Implant supported overdenture with splinted locator attachment ➢ Implant supported overdenture with non-splinted telescopic attachment ➢ Implant supported overdenture with splinted telescopic attachment

Discretization process (Figures 7 and 8)

This procedure includes creating the mesh, elements with their respective nodes and defining boundary conditions. Meshing divides the body into finite number of elements, each element having nodes. The total number of elements and nodes for each model are mentioned in Table II. As an alternative to the quadratic tetrahedral elements in ABAQUS/Standard (C3D10 or C3D10I), the modified quadratic tetrahedral element (C3D10M) was employed. This element was robust for large-deformation and contact problems using either the traditional node-to-surface or the surface-to-surface contact discretization. It also exhibits minimal shear and volumetric locking.
Table II

Number of elements and nodes for each model.

S.NoComponentElement TypeElementsNodes
1Cortical boneC3D101133093196993
2Cancellous BoneC3D1013764566882
3GingivaC3D1015736095009
4ImplantC3D10173820110234
5Nylon capC3D1011515922838
6Telescopic attachmentC3D10153218229
7ScrewC3D1013802856653
8SplintC3D1012165033229
9DentureC3D10177208115810
Total772559503491
The forces and the boundary conditions were defined to simulate applied loads and constraints of the structure. Boundary conditions reflect the real situation of the displacement produced at each node. It was defined to simulate the real condition by releasing and restraining some nodes from movement or rotation according to the nature of the 3-Dimensional model. In the present study, contacts with friction (coefficient of friction 0.1) were specified. They were introduced between overdenture and mucosa, and between parts of both the selected attachments to simulate the interactions existing between these bodies. Contact within the attachment assemblies was essential to reproduce the behavior of the two retention mechanisms studied. Implants were considered totally osseointegrated, so a mechanically perfect interface was presumed between implants and bone. A vertical compressive load of 35 Newtons was introduced for all the assemblies in the first molar region to simulate occlusal load. A nonlinear contact stress analysis was performed using ABAQUS/Standard and the stress levels were determined. The stress distribution pattern around each implant was provided in the form of 3Dimensional static models made up of the surrounding bone around each dental implant together with the stresses represented by color coded zones; red as maximum and dark blue as minimum. The color and size of each zone represents the stresses occurring within (Von Mises patterns). The values were recorded and tabulated for four different clinical situations.

Ethics approval

The study was reviewed and approved by Ethics Committee of the Army College of Dental Sciences, Secunderabad, India (ACDS/IEC/11/September 2018).

Results

Stress (Table III)

Von Mises stress fields were traced in the form of color-coded bands. The stress distribution in different components were analyzed based on the color-coded bands with red being the highest followed by orange, yellow, light green, green, light blue, blue and dark blue in descending order.

Distribution of stresses in non-splinted attachments (Figures 9 and 10)

When the non-splinted attachment models were compared, the stress on cortical bone was more with locator attachment when compared to telescopic, whereas on cancellous bone it was more with telescopic. The stress on gingiva showed no difference between the two models. On the other hand, the stress on cap, implant and attachment was more with telescopic attachment when compared to locator.

Distribution of stresses in splinted attachments (Figures 11 and 12)

When the splinted attachment models were compared, the stress on cortical and cancellous bones was more for the locator attachment. The stress on gingiva showed no difference between the two models. On the other hand, the stress on cap, attachments and splinted bars were more with telescopic attachments. The stress on implant and screw were almost similar with locator showing slightly higher values.

Deflection (Table IV)

When the non-splinted models were compared, the deflection was more with the locator attachment in all the components, except cap. Even in the splinted models, the deflections were more with the locator attachment in all the components, except cap.

Discussion

Proper prosthetic rehabilitation can minimize the bone resorption that occurs after the loss of teeth [11,13]. With the advent and success of osseointegrated dental implant, the concept of IOs has been accepted world wide as a reliable treatment protocol for the management of completely edentulous patients [15-19]. The IOs have become the standard of care because of the greater stability derived from the mechanical attachment retaining the restoration, limited lateral movements that consequently minimize soft tissue trauma [17,26,27]. IOs are subjected to various types of axial and non-axial stresses, including the masticatory forces. The resultant of these forces is transmitted to the implant through the superstructure via the attachments [7]. As the titanium implants are stiffer than natural teeth and as implant–bone interface is rigid, the loads are directly transmitted to the adjacent bone [10]. Thus, the ability of the attachments to dissipate the stresses transmitted by the superstructures influences the prognosis and the success of the implants. In the present study, the tapered implants have been considered for both the attachment systems, as it is reported to provide better stress distribution [16,22]. The techniques like strain gauge, photo-elasticity and FEA have been employed for evaluating the stress distribution in IOs with various attachments [17]. FEA has become an increasingly useful tool for studying the effects of stress on implant and surrounding bone, thus making it an effective computational tool that has been adapted from the engineering arena to dental implants [43]. In the present study, 3D FEA is considered as it is predominantly viewed as the most suitable tool [33-35]; additional advantages being the representation of complex geometries accurately, easy model modifications as well as the depiction of internal stress and other mechanical quantities. Four clinical situations are simulated in the models, splinted and non-splinted implants with locator and telescopic attachments. A nonlinear contact stress analysis was used to analyze the stress pattern, as linear static analysis cannot represent proper physics of the problem, due to complexities involved in analyzing the total assembly with different non-linear contacts. Linear analysis is based on the static and linearity assumptions. When these assumptions fail, linear analysis will produce wrong predictions. Hence, nonlinear analysis is apt to model the nonlinearities of the present design. Amount of force applied on the models in the present study was 35 N. This is because it simulated the bite forces of edentulous patients with overdentures supported by implants in the mandible [34]. During mastication, loads are transferred to alveolar bone surrounding the IOs [34]. The stresses induced by the occlusal loads are initially transferred from the implant to the cortical bone, while a small amount of remaining stresses to the cancellous bone. It has been observed that cortical bone has a greater ability to transfer stress, because of higher elastic modulus [33,34]. A key factor for success or failure of dental implants is dependent on the manner in which stresses are transferred to peri-implant bone. The influence of different types of attachments on peri-implant stress has been investigated [33,35]. In the present study, stress transferred to the cortical bone in splinted and non-splinted locator attachment was more than telescopic attachment. On the other hand, in the components above the mucosa like the caps, implants and attachments, the amount of contact stresses are less with locator attachment than telescopic attachments, indicating a possibility of superior performance and greater prosthesis life span. The time needed between the successive maintenance sessions can also be expected to be less. The stress created on the implant was also less with the locator attachment, 2.1 MPa, as compared to 8.73 MPa for telescopic attachments, which is a clinical advantage. This can be attributed to the geometrical design of locator attachment with smaller height and wider diameter that allows better dissipation of stresses that resulted from the occlusal load application. Another factor is that the material of locator attachment is titanium, whose elastic modulus is 63% more than gold of telescopic attachment [39-42]. Thus, the section modulus, bending resistance, strength and bending moment of inertia are more for locator attachment than telescopic attachment. When stress patterns generated in splinted and non-splinted models in both the attachment types were compared, stresses were less in non-splinted model. This can be attributed to the fact that, in non-splinted attachment model only vertical compressive forces act. On the contrary, in splinted ones, the combined vertical compressive force along with the bending moment might have created high stress. Also due to the cantilever effect of splinted bar, the deflection was of higher value causing high stresses at the level of the contact zone of the abutment, implant and screw. The major limitations of the present study are that the stress distribution has been evaluated only under vertical load and consideration of the lowest possible force of 35 N. Another limitation is the assumption of bone as isotropic and homogenous, though the tissue behavior is not. The FEA is a numerical mathematical solution technique, with possible numerical errors and differences in the stresses from one configuration to another. The stress singularities and notch sensitivities in each model might also influence the results. The FEA cannot be used to reproduce the tissue behavior, but can approximate it and provide partially relevant results. Hence, further randomized clinical studies on this topic are needed to draw final conclusions, in spite of the superiority of locator over telescopic attachment as reported in the present study. - The contact stresses developed on the attachment and implant components were less in the locator model when compared to telescopic, irrespective of splinting procedure. The stresses transferred to the supporting structure, cortical bone, were more with locator attachment compared to the telescopic one, in both non-splinted and splinted models. - The stresses in all the components of overdenture were greater in the splinted model compared with the non-splinted one, irrespective of the attachment type. - Thus, from a clinical viewpoint, locator attachment can be considered as a suitable alternative to telescopic for IOs. On the other hand, non-splinted design is preferable when compared to the splinted one. Implant supported overdenture – 3D model. Implant supported overdenture, non-splinted and locator attachments. Geometric design of implant supported overdenture, non-splinted and locator attachment. Implant supported overdenture, non-splinted and telescopic attachment. Geometric design of implant supported overdenture, non-splinted and telescopic attachment. Geometric design of implant supported overdenture, splinted attachments. Meshing of overdenture, non-splinted and locator attachment. Meshing of overdenture, splinted locator (A,B) and telescopic attachments (C,D). Von Mises stress contour plot- overdenture, non-splinted and locator attachment. Von Mises stress contour plot- overdenture, non-splinted and telescopic attachment. Von Mises stress contour plot- overdenture, splinted and locator attachment. Von Mises stress contour plot- overdenture, splinted and telescopic attachment. Material properties incorporated in the study. GPa: Gigapascal, g/cm3: Grams per cubic millimeter, HU: Hounsfield unit Number of elements and nodes for each model. Contact stress induced for vertical compressive load of 35 Newtons. Deflection for vertical compressive load of 35 Newtons. E: Exponential form
Table III

Contact stress induced for vertical compressive load of 35 Newtons.

Stress (in Megapascal)
S.NoComponentsNon-SplintedSplinted
LocatorTelescopicLocatorTelescopic
1Cortical Bone3.732.664.123.7
2Cancellous Bone0.2950.491.171.05
3Gingiva0.140.1380.210.22
4Cap5.740.57.4261.47
5Implant2.18.7325.3524.2
6Attachment10.2526.4112.130.19
7Screw--34.530.89
8Splinted Bar--43.3248.36
9Abutment--57.6554.22
Table IV

Deflection for vertical compressive load of 35 Newtons.

Deflection (in millimeters)
S.NoComponentsNon-splintedSplinted
LocatorTelescopicLocatorTelescopic
1Cortical Bone6.15E-044.14E-044.52E-044.19E-04
2Cancellous Bone1.18E-031.09E-038.93E-047.89E-04
3Gingiva9.72E-029.25E-021.16E-011.18E-01
4Cap1.34E-028.36E-032.98E-025.85E-02
5Implant7.61E-044.58E-041.11E-031.00E-03
6Attachment / Attachment on splinted bar9.40E-043.59E-039.61E-038.73E-03
7Screw--8.63E-048.11E-04
8Splinted Bar--1.88E-021.77E-02
9Abutment--4.82E-034.45E-03

E: Exponential form

  35 in total

Review 1.  Mandibular implant overdenture treatment: consensus and controversy.

Authors:  D R Burns
Journal:  J Prosthodont       Date:  2000-03       Impact factor: 2.752

Review 2.  The mandibular complete overdenture.

Authors:  David R Burns
Journal:  Dent Clin North Am       Date:  2004-07

Review 3.  A review of the functional and psychosocial outcomes of edentulousness treated with complete replacement dentures.

Authors:  Patrick Finbarr Allen; Anne Sinclair McMillan
Journal:  J Can Dent Assoc       Date:  2003-11       Impact factor: 1.316

4.  Implant-supported mandibular overdentures retained with ball or telescopic crown attachments: a 3-year prospective study.

Authors:  Gerald Krennmair; Michael Weinländer; Martin Krainhöfner; Eva Piehslinger
Journal:  Int J Prosthodont       Date:  2006 Mar-Apr       Impact factor: 1.681

5.  Telescopic crowns as attachments for implant supported restorations: a case series.

Authors:  Oliver Hoffmann; Christian Beaumont; Dimitris N Tatakis; Gregory-George Zafiropoulos
Journal:  J Oral Implantol       Date:  2006       Impact factor: 1.779

6.  Treatment planning of the edentulous mandible.

Authors:  W Chee; S Jivraj
Journal:  Br Dent J       Date:  2006-09-23       Impact factor: 1.626

7.  The effects of two attachment types on the stresses introduced to the mandibular residual ridge: a 3D finite element analysis.

Authors:  Mohammad Hossein Dashti; Parsa Atashrazm; Mehdi Imani Emadi; Shiva Mishaeel; Sepideh Banava
Journal:  Quintessence Int       Date:  2013       Impact factor: 1.677

8.  The continuing reduction of the residual alveolar ridges in complete denture wearers: a mixed-longitudinal study covering 25 years.

Authors:  A Tallgren
Journal:  J Prosthet Dent       Date:  1972-02       Impact factor: 3.426

9.  The maintenance requirements of mandibular overdentures stabilized by Astra Tech implants using three different attachment mechanisms--balls, magnets, and bars; 3-year results.

Authors:  D M Davis; M E Packer
Journal:  Eur J Prosthodont Restor Dent       Date:  2000-12

10.  Epidemiological survey on edentulousness.

Authors:  N Simhachalam Reddy; Nallala Amarendra Reddy; R Narendra; Sashi Deepth Reddy
Journal:  J Contemp Dent Pract       Date:  2012-07-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.