Literature DB >> 11692994

The maintenance requirements of mandibular overdentures stabilized by Astra Tech implants using three different attachment mechanisms--balls, magnets, and bars; 3-year results.

D M Davis1, M E Packer.   

Abstract

Thirty seven people were provided with mandibular overdentures stabilized by Astra Tech implants. Thirteen people were provided with ball attachments, 12 with magnet attachments and 12 with bar attachments. The patients were followed for 3 years and detailed records were kept of the extent of maintenance required after placement of the dentures. The bar attachment mechanism required 9 episodes of maintenance, compared to 38 for the ball attachment mechanism and 23 for the magnet attachment mechanism. There was no difference between the three groups for the amount of maintenance required by the overdentures. The design of the ball attachment changed during the study from a two piece to a one piece abutment. It is likely that had this "all in one" attachment been available from the beginning of the study, the amount of maintenance required by the ball attachment mechanism would have been considerably less.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11692994

Source DB:  PubMed          Journal:  Eur J Prosthodont Restor Dent        ISSN: 0965-7452


  5 in total

1.  Immediate loading on mandibular edentulous patient with SFI Bar® overdenture.

Authors:  Ha-Young Kim; Ryan Jin-Young Kim; Sarah Qadeer; Chang-Mo Jeong; Sang-Wan Shin; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2011-03-31       Impact factor: 1.904

2.  Attachment systems for mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Jeong-Yol Lee; Sang-Wan Shin; S Ross Bryant
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

3.  Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Sang-Wan Shin; Jeong-Yol Lee
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

4.  Microbiological evaluation of LOCATOR® Legacy attachments: A cross-sectional clinical study.

Authors:  Ursina Nagy; Christophe Guédat; Catherine Giannopoulou; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2019-07-18

5.  Comparison of stress induced in mandible around an implant-supported overdenture with locator attachment and telescopic crowns - a finite element analysis.

Authors:  Meer Rownaq Ali Abbasi; Dileep Nag Vinnakota; Vijaya Sankar; Rekhalakshmi Kamatham
Journal:  Med Pharm Rep       Date:  2020-04-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.