Literature DB >> 23757462

The effects of two attachment types on the stresses introduced to the mandibular residual ridge: a 3D finite element analysis.

Mohammad Hossein Dashti1, Parsa Atashrazm, Mehdi Imani Emadi, Shiva Mishaeel, Sepideh Banava.   

Abstract

PURPOSE: Two commonly used attachment systems for implant-retained overdentures are bar and ball systems. The aim of this study was to compare these two types of attachments on the basis of the stresses introduced to the mandibular posterior residual ridge by an overdenture retained by two implants. METHOD AND MATERIALS: A basic model was generated from the data provided by a CT scan of a patient's mandible, the diagnostic casts, and the existing overdenture. Two root-form implants were placed in the anterior mandible. Models were used to simulate two situations: The first model represented an edentulous mandible supporting an overdenture retained by two implants connected with a bar and plastic clip system, and in the second model two ball attachments with nylon caps were used as the retention mechanism. A 35 N vertical load was introduced to the first molar region of each group to simulate the occlusal forces of the maxillary complete denture. The stresses in the mandibular residual ridges under the first molar region were measured using Ansys software.
RESULTS: The bar-retained overdenture introduced higher stresses to the posterior mandibular residual ridge compared to the ball-retained overdenture (0.4 MPa and 0.1 MPa, respectively).
CONCLUSION: Within the limitations of this study, the ball system was shown to introduce a lower amount of stress to the posterior mandibular residual ridge compared to a bar and clip system.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23757462     DOI: 10.3290/j.qi.a29753

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  4 in total

1.  Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study.

Authors:  Angel Alvarez-Arenal; Ignacio Gonzalez-Gonzalez; Hector deLlanos-Lanchares; Elena Martin-Fernandez; Aritza Brizuela-Velasco; Joseba Ellacuria-Echebarria
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

2.  Comparison of stress induced in mandible around an implant-supported overdenture with locator attachment and telescopic crowns - a finite element analysis.

Authors:  Meer Rownaq Ali Abbasi; Dileep Nag Vinnakota; Vijaya Sankar; Rekhalakshmi Kamatham
Journal:  Med Pharm Rep       Date:  2020-04-22

3.  Effects of overdenture attachment systems with different working principles on stress transmission: A three-dimensional finite element study.

Authors:  Nurullah Turker; Ulviye Sebnem Buyukkaplan
Journal:  J Adv Prosthodont       Date:  2020-12-28       Impact factor: 1.904

Review 4.  Peri-implant stress distribution assessment of various attachment systems for implant supported overdenture prosthesis by finite element analysis - A systematic review.

Authors:  Bappaditya Bhattacharjee; Ritu Saneja; Ankita Singh; Pavan Kumar Dubey; Atul Bhatnagar
Journal:  J Oral Biol Craniofac Res       Date:  2022-09-07
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.