Literature DB >> 24179972

A 3-year prospective clinical study of telescopic crown, bar, and locator attachments for removable four implant-supported maxillary overdentures.

Duohong Zou, Yiqun Wu, Wei Huang, Feng Wang, Shen Wang, Zhiyong Zhang, Zhiyuan Zhang.   

Abstract

PURPOSE: To evaluate telescopic crown (TC), bar, and locator attachments used in removable four implant-supported overdentures for patients with edentulous maxillae.
MATERIALS AND METHODS: A total of 30 maxillary edentulous patients were enrolled in a 3-year prospective study. Ten patients (group A) were treated with overdentures supported by TCs, 10 patients (group B) with overdentures supported by bar attachments, and 10 patients (group C) with overdentures supported by locator attachments. A total of 120 implants were used to restore oral function. During the 3-year follow-up period, implant survival and success rates, biologic and mechanical complications, prosthodontic maintenance efforts, and patient satisfaction were evaluated.
RESULTS: All 30 patients were available for the 3-year follow-up and exhibited 100% implant survival and success rates. Peri-implant marginal bone resorption was not statistically significant for the three groups. There were lower plaque, bleeding, gingiva, and calculus indices in group C compared with groups A and B. The number of prosthodontic maintenance visits revealed eight complications in the TC group, seven complications in the bar group, and four complications in the locator group. However, there were no differences in the clinical effects of the overdentures in the three groups.
CONCLUSION: Within the limits of this prospective study, it was concluded that the locator system produced superior clinical results compared with the TC and bar attachments in terms of peri-implant hygiene parameters, the frequency of prosthodontic maintenance measures, cost, and ease of denture preparation. However, longer-term prospective studies are required to confirm these results.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24179972     DOI: 10.11607/ijp.3485

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  13 in total

1.  Locator® versus ceramic/electroplated double-crown attachments: a prospective study on the intraindividual comparison of implant-supported mandibular prostheses.

Authors:  Silvia Brandt; Jan Brandt; Ali-Reza Ketabi; Hans-Christoph Lauer; Anna Kunzmann
Journal:  Clin Oral Investig       Date:  2018-05-19       Impact factor: 3.573

2.  Patient satisfaction and survival of maxillary overdentures supported by four or six splinted implants: a systematic review with meta-analysis.

Authors:  Fabrizio Di Francesco; Emilio A Cafferata; Gennaro De Marco; Estefani B Capcha; Alessandro Lanza; Corina M Cristache; Rolando Vernal
Journal:  BMC Oral Health       Date:  2021-05-08       Impact factor: 2.757

Review 3.  A systematic review and meta-analysis of removable and fixed implant-supported prostheses in edentulous jaws: post-loading implant loss.

Authors:  Jaana-Sophia Kern; Thomas Kern; Stefan Wolfart; Nicole Heussen
Journal:  Clin Oral Implants Res       Date:  2015-02-09       Impact factor: 5.977

4.  Maxillary overdentures supported by four or six implants in the anterior region: 5-year results from a randomized controlled trial.

Authors:  Wim Slot; Gerry M Raghoebar; Marco S Cune; Arjan Vissink; Henny J A Meijer
Journal:  J Clin Periodontol       Date:  2016-10-14       Impact factor: 8.728

5.  Microbiological evaluation of LOCATOR® Legacy attachments: A cross-sectional clinical study.

Authors:  Ursina Nagy; Christophe Guédat; Catherine Giannopoulou; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2019-07-18

6.  Comparison of stress induced in mandible around an implant-supported overdenture with locator attachment and telescopic crowns - a finite element analysis.

Authors:  Meer Rownaq Ali Abbasi; Dileep Nag Vinnakota; Vijaya Sankar; Rekhalakshmi Kamatham
Journal:  Med Pharm Rep       Date:  2020-04-22

7.  Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review.

Authors:  Jeong-Gyo Seo; Jin-Hyun Cho
Journal:  J Adv Prosthodont       Date:  2020-02-20       Impact factor: 1.904

8.  Wear, microleakage and plastic deformation of an implant-supported chair-side bar system.

Authors:  Christian Johannes Mehl; Martin Steiner; Klaus Ludwig; Matthias Kern
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

9.  Clinical performance of LOCATOR® attachments: A retrospective study with 1-8 years of follow-up.

Authors:  Christophe Guédat; Ursina Nagy; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2018-07-27

10.  Maxillary Implant-Supported Overdentures: Mechanical Behavior Comparing Individual Axial and Bar Retention Systems. A Cohort Study of Edentulous Patients.

Authors:  José Félix Mañes Ferrer; Lucía Fernández-Estevan; Eduardo Selva-Otaolaurruchi; Carlos Labaig-Rueda; María Fernanda Solá-Ruíz; Rubén Agustín-Panadero
Journal:  Medicina (Kaunas)       Date:  2020-03-19       Impact factor: 2.430