Literature DB >> 32248231

Stent and leaflet stresses across generations of balloon-expandable transcatheter aortic valves.

Yue Xuan1, Danny Dvir2, Zhongjie Wang1, Jian Ye3, Julius M Guccione1, Liang Ge1, Elaine E Tseng1.   

Abstract

OBJECTIVES: Transcatheter aortic valve replacement (TAVR) is established therapy for severe aortic stenosis patients with intermediate-, high- and prohibitive-risk for surgery. A significant challenge when expanding TAVR to low-risk and younger patients is the unknown long-term durability. High leaflet stresses have been associated with surgical bioprosthetic valve degeneration. In this study, we examined the impact of changes in valve design across 3 generations of same-sized TAVR devices on stent and leaflet stresses.
METHODS: The 26-mm Edwards SAPIEN, 23, 26 and 29 mm SAPIEN XT (XT) and 26 mm SAPIEN 3 (S3) (n = 1 each) underwent micro-computed tomography (micro-CT) scanning. Dynamic finite element computational simulations of 23-26 mm SAPIEN, 23-29 mm XT and 23-29 mm S3 were performed with physiological loading and micro-CT or scaled geometries.
RESULTS: Peak stresses were concentrated in the commissure area and along the bottom of the suture, representing areas most likely to develop structural valve degeneration across TAVR generations. Latest-generation S3 showed greatest 99th percentile principal stress on commissural leaflets for 26 and 29 mm, and increased stresses over XT for 23 mm. Percentage of higher stress areas within the leaflets steadily increased across generations, 3.8%, 3.9% and 5.7%, respectively, for 26 mm SAPIEN, XT and S3 with similar trend for 29-mm valves.
CONCLUSIONS: Using computational simulations based on high-fidelity modelling of balloon-expandable TAVRs, our study demonstrated that maximum stress areas existed in similar leaflet locations across SAPIEN generations, while the latest model S3 had the highest magnitude for both 26- and 29-mm valves. S3 also had the largest area of higher stresses than other generations, which would be prone to degeneration. Our study coupled with future long-term clinical outcomes >10 years will provide insight on biomechanics of TAVR degeneration. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery 2020. This work is written by US Government employees and is in the public domain in the US.

Entities:  

Keywords:  Balloon expandable; Computational simulation; Durability; Transcatheter heart valve

Mesh:

Year:  2020        PMID: 32248231      PMCID: PMC7248644          DOI: 10.1093/icvts/ivaa037

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  23 in total

1.  Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion.

Authors:  Mostafa Abbasi; Ali N Azadani
Journal:  J Biomech       Date:  2015-08-21       Impact factor: 2.712

2.  Simulated bioprosthetic heart valve deformation under quasi-static loading.

Authors:  Wei Sun; Ajay Abad; Michael S Sacks
Journal:  J Biomech Eng       Date:  2005-11       Impact factor: 2.097

3.  Leaflet Mechanical Properties of Carpentier-Edwards Perimount Magna Pericardial Aortic Bioprostheses.

Authors:  Heide Kuang; Yue Xuan; Michelle Lu; Aart Mookhoek; Andrew D Wisneski; Julius M Guccione; Liang Ge; Elaine E Tseng
Journal:  J Heart Valve Dis       Date:  2017-01

4.  Stent and leaflet stresses in 26-mm, third-generation, balloon-expandable transcatheter aortic valve.

Authors:  Yue Xuan; Danny Dvir; Zhongjie Wang; Trek Mizoguchi; Jian Ye; Julius M Guccione; Liang Ge; Elaine E Tseng
Journal:  J Thorac Cardiovasc Surg       Date:  2018-05-28       Impact factor: 5.209

Review 5.  TAVI and valve performance: update on definitions, durability, transcatheter heart valve failure modes and management.

Authors:  Hélène Eltchaninoff; Eric Durand; Marco Barbanti; Mohamed Abdel-Wahab
Journal:  EuroIntervention       Date:  2018-08-31       Impact factor: 6.534

6.  Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients.

Authors:  Jeffrey J Popma; G Michael Deeb; Steven J Yakubov; Mubashir Mumtaz; Hemal Gada; Daniel O'Hair; Tanvir Bajwa; John C Heiser; William Merhi; Neal S Kleiman; Judah Askew; Paul Sorajja; Joshua Rovin; Stanley J Chetcuti; David H Adams; Paul S Teirstein; George L Zorn; John K Forrest; Didier Tchétché; Jon Resar; Antony Walton; Nicolo Piazza; Basel Ramlawi; Newell Robinson; George Petrossian; Thomas G Gleason; Jae K Oh; Michael J Boulware; Hongyan Qiao; Andrew S Mugglin; Michael J Reardon
Journal:  N Engl J Med       Date:  2019-03-16       Impact factor: 91.245

7.  The effects of transcatheter valve crimping on pericardial leaflets.

Authors:  S Hamed Alavi; Elliott M Groves; Arash Kheradvar
Journal:  Ann Thorac Surg       Date:  2014-01-18       Impact factor: 4.330

8.  Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve.

Authors:  Yue Xuan; Kapil Krishnan; Jian Ye; Danny Dvir; Julius M Guccione; Liang Ge; Elaine E Tseng
Journal:  J Thorac Cardiovasc Surg       Date:  2016-12-23       Impact factor: 5.209

9.  Early structural valve deterioration of Mitroflow aortic bioprosthesis: mode, incidence, and impact on outcome in a large cohort of patients.

Authors:  Thomas Sénage; Thierry Le Tourneau; Yohann Foucher; Sabine Pattier; Caroline Cueff; Magali Michel; Jean-Michel Serfaty; Antoine Mugniot; Christian Périgaud; Hubert François Carton; Ousama Al Habash; Olivier Baron; Jean Christian Roussel
Journal:  Circulation       Date:  2014-10-29       Impact factor: 29.690

10.  Patient-specific AAA wall stress analysis: 99-percentile versus peak stress.

Authors:  L Speelman; E M H Bosboom; G W H Schurink; F A M V I Hellenthal; J Buth; M Breeuwer; M J Jacobs; F N van de Vosse
Journal:  Eur J Vasc Endovasc Surg       Date:  2008-10-11       Impact factor: 7.069

View more
  1 in total

Review 1.  Transcatheter aortic valve replacement for bicuspid aortic valve disease: does conventional surgery have a future?

Authors:  Breandan B Yeats; Pradeep K Yadav; Lakshmi P Dasi; Vinod H Thourani
Journal:  Ann Cardiothorac Surg       Date:  2022-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.