Literature DB >> 28108064

Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve.

Yue Xuan1, Kapil Krishnan1, Jian Ye2, Danny Dvir3, Julius M Guccione1, Liang Ge1, Elaine E Tseng4.   

Abstract

OBJECTIVE: Transcatheter aortic valve replacement is established therapy for high-risk and inoperable patients with severe aortic stenosis, but questions remain regarding long-term durability. Valve design influences durability. Increased leaflet stresses in surgical bioprostheses have been correlated with degeneration; however, transcatheter valve leaflet stresses are unknown. From 2007 to 2014, a majority of US patients received first-generation balloon-expandable transcatheter valves. Our goal was to determine stent and leaflet stresses in this valve design using finite element analyses.
METHODS: A 26-mm Sapien Transcatheter Heart Valve (Edwards Lifesciences, Inc, Irvine, Calif) underwent high-resolution microcomputed tomography scanning to develop precise 3-dimensional geometry of the leaflets, the stent, and the polyethylene terephthalate elements. The stent was modeled using 3-dimensional elements and the leaflets were modeled using shell elements. Stent material properties were based on stainless steel, whereas those for leaflets were obtained from surgical bioprostheses. Noncylindrical Sapien valve geometry was also simulated. Pressure loading to 80 mm Hg and 120 mm Hg was performed using ABAQUS finite element software (Dassault Systèmes, Waltham, Mass).
RESULTS: At 80 mm Hg, maximum principal stresses on Sapien leaflets were 1.31 megaspascals (MPa). Peak leaflet stress was observed at commissural tips where leaflets connected to the stent. Maximum principal stresses for the stent were 188.91 MPa and located at stent tips where leaflet commissures were attached. Noncylindrical geometry increased peak principal leaflet stresses by 16%.
CONCLUSIONS: Using exact geometry from high-resolution scans, the 26-mm Sapien Transcatheter Heart Valve showed that peak stresses for both stent and leaflets were present at commissural tips where leaflets were attached. These regions would be prone to leaflet degeneration. Understanding stresses in first-generation transcatheter valves allows comparison to future designs for relative durability.
Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  durability; finite element; stress; transcatheter aortic valve

Mesh:

Year:  2016        PMID: 28108064      PMCID: PMC5837867          DOI: 10.1016/j.jtcvs.2016.12.016

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  25 in total

1.  Simulated elliptical bioprosthetic valve deformation: implications for asymmetric transcatheter valve deployment.

Authors:  Wei Sun; Kewei Li; Eric Sirois
Journal:  J Biomech       Date:  2010-12-01       Impact factor: 2.712

2.  Long-term durability of bioprosthetic aortic valves: implications from 12,569 implants.

Authors:  Douglas R Johnston; Edward G Soltesz; Nakul Vakil; Jeevanantham Rajeswaran; Eric E Roselli; Joseph F Sabik; Nicholas G Smedira; Lars G Svensson; Bruce W Lytle; Eugene H Blackstone
Journal:  Ann Thorac Surg       Date:  2015-02-04       Impact factor: 4.330

3.  Transcatheter versus surgical aortic-valve replacement in high-risk patients.

Authors:  Craig R Smith; Martin B Leon; Michael J Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; Mathew Williams; Todd Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H Thourani; Paul Corso; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Jodi J Akin; William N Anderson; Duolao Wang; Stuart J Pocock
Journal:  N Engl J Med       Date:  2011-06-05       Impact factor: 91.245

4.  Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: assessment by multidetector computed tomography.

Authors:  Alexander B Willson; John G Webb; Ronen Gurvitch; David A Wood; Stefan Toggweiler; Ronald Binder; Melanie Freeman; Mark Madden; Cameron Hague; Jonathon Leipsic
Journal:  JACC Cardiovasc Interv       Date:  2012-05       Impact factor: 11.195

5.  5-year outcomes of transcatheter aortic valve replacement compared with standard treatment for patients with inoperable aortic stenosis (PARTNER 1): a randomised controlled trial.

Authors:  Samir R Kapadia; Martin B Leon; Raj R Makkar; E Murat Tuzcu; Lars G Svensson; Susheel Kodali; John G Webb; Michael J Mack; Pamela S Douglas; Vinod H Thourani; Vasilis C Babaliaros; Howard C Herrmann; Wilson Y Szeto; Augusto D Pichard; Mathew R Williams; Gregory P Fontana; D Craig Miller; William N Anderson; Jodi J Akin; Michael J Davidson; Craig R Smith
Journal:  Lancet       Date:  2015-03-15       Impact factor: 79.321

6.  Early effects of transcatheter aortic valve implantation and aortic valve replacement on myocardial function and aortic valve hemodynamics: insights from cardiovascular magnetic resonance imaging.

Authors:  Gareth Crouch; Jayme Bennetts; Ajay Sinhal; Phillip J Tully; Darryl P Leong; Craig Bradbrook; Amy L Penhall; Carmine G De Pasquale; Adhiraj Chakrabarty; Robert A Baker; Joseph B Selvanayagam
Journal:  J Thorac Cardiovasc Surg       Date:  2014-10-17       Impact factor: 5.209

7.  Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment.

Authors:  Qian Wang; Eric Sirois; Wei Sun
Journal:  J Biomech       Date:  2012-06-13       Impact factor: 2.712

8.  Simulation of long-term fatigue damage in bioprosthetic heart valves: effects of leaflet and stent elastic properties.

Authors:  Caitlin Martin; Wei Sun
Journal:  Biomech Model Mechanobiol       Date:  2013-10-04

9.  Aortic root surgery in the United States: a report from the Society of Thoracic Surgeons database.

Authors:  Sotiris C Stamou; Mathew L Williams; Tyler M Gunn; Robert C Hagberg; Kevin W Lobdell; Nicholas T Kouchoukos
Journal:  J Thorac Cardiovasc Surg       Date:  2014-05-21       Impact factor: 5.209

10.  Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients.

Authors:  Martin B Leon; Craig R Smith; Michael J Mack; Raj R Makkar; Lars G Svensson; Susheel K Kodali; Vinod H Thourani; E Murat Tuzcu; D Craig Miller; Howard C Herrmann; Darshan Doshi; David J Cohen; Augusto D Pichard; Samir Kapadia; Todd Dewey; Vasilis Babaliaros; Wilson Y Szeto; Mathew R Williams; Dean Kereiakes; Alan Zajarias; Kevin L Greason; Brian K Whisenant; Robert W Hodson; Jeffrey W Moses; Alfredo Trento; David L Brown; William F Fearon; Philippe Pibarot; Rebecca T Hahn; Wael A Jaber; William N Anderson; Maria C Alu; John G Webb
Journal:  N Engl J Med       Date:  2016-04-02       Impact factor: 91.245

View more
  7 in total

1.  A geometrically adaptable heart valve replacement.

Authors:  Sophie C Hofferberth; Mossab Y Saeed; Lara Tomholt; Matheus C Fernandes; Christopher J Payne; Karl Price; Gerald R Marx; Jesse J Esch; David W Brown; Jonathan Brown; Peter E Hammer; Richard W Bianco; James C Weaver; Elazer R Edelman; Pedro J Del Nido
Journal:  Sci Transl Med       Date:  2020-02-19       Impact factor: 17.956

Review 2.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

3.  Percutaneous aortic and mitral valve repair - from bench testing to simulators and clinical data: Percutaneous aortic and mitral valve repair.

Authors:  Paul T L Chiam; Huay Cheem Tan
Journal:  AsiaIntervention       Date:  2020-12-02

4.  Impact of Transcatheter Aortic Valve Size on Leaflet Stresses: Implications for Durability and Optimal Grey Zone Sizing.

Authors:  Yue Xuan; Danny Dvir; Andrew D Wisneski; Zhongjie Wang; Jian Ye; Julius M Guccione; Liang Ge; Elaine E Tseng
Journal:  AsiaIntervention       Date:  2020-12

5.  Stent and leaflet stresses across generations of balloon-expandable transcatheter aortic valves.

Authors:  Yue Xuan; Danny Dvir; Zhongjie Wang; Jian Ye; Julius M Guccione; Liang Ge; Elaine E Tseng
Journal:  Interact Cardiovasc Thorac Surg       Date:  2020-06-01

Review 6.  Biomechanics of Transcatheter Aortic Valve Implant.

Authors:  Francesco Nappi; Sanjeet Singh Avtaar Singh; Pierluigi Nappi; Antonio Fiore
Journal:  Bioengineering (Basel)       Date:  2022-07-04

7.  A Finite Element Analysis Study from 3D CT to Predict Transcatheter Heart Valve Thrombosis.

Authors:  Francesco Nappi; Laura Mazzocchi; Irina Timofeva; Laurent Macron; Simone Morganti; Sanjeet Singh Avtaar Singh; David Attias; Antonio Congedo; Ferdinando Auricchio
Journal:  Diagnostics (Basel)       Date:  2020-03-26
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.