Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion.

Mostafa Abbasi1, Ali N Azadani2.   

Abstract

Transcatheter aortic valve replacement (TAVR) is an established treatment alternative to surgical valve replacement in high-risk patients with severe symptomatic aortic stenosis. The current guidelines for TAVR are to upsize transcatheter aortic valve (TAV) relative to the native annulus to secure the device and minimize paravalvular leakage. Unlike surgical stented bioprosthetic valves where leaflets are attached to a rigid frame, TAVs must expand to fit within the native annulus. Fully-expanded circular TAVs have consistent leaflet kinematics; however, subtle variations in the degree of stent expansion may affect leaflet coaptation. The objective of this study was to determine the impact of incomplete TAV expansion on leaflet stress and strain distributions. In this study, we developed finite element models of a 23 mm homemade TAV expanded to diameters ranging from 18 to 23 mm in 1mm increments. Through dynamic finite element simulations, we found that leaflet stress and strain distributions were dependent on the diameter of the inflated TAV. After complete expansion of the TAV to 23 mm, high stress and strain regions were observed primarily in the commissures during diastole. However, 2-3mm incomplete TAV stent expansion induced localized high stress regions within the TAV commissures, while 4-5mm incomplete stent expansion induced localized high stress regions within the belly of the TAV leaflets during the diastolic phase of the cardiac cycle. Increased mechanical stress and flexural deformation on TAV leaflets due to incomplete stent expansion may lead to accelerated tissue degeneration and diminished long-term valve durability.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Finite element modeling; Incomplete stent expansion; Oversizing; Stress and strain; Transcatheter aortic valve replacement

Mesh:

Year:  2015        PMID: 26338100     DOI: 10.1016/j.jbiomech.2015.08.012

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  22 in total

1.  Transcatheter Valve Underexpansion Limits Leaflet Durability: Implications for Valve-in-Valve Procedures.

Authors:  Caitlin Martin; Wei Sun
Journal:  Ann Biomed Eng       Date:  2016-10-12       Impact factor: 3.934

2.  Bovine Pericardium of High Fibre Dispersion Has High Fatigue Life and Increased Collagen Content; Potentially an Untapped Source of Heart Valve Leaflet Tissue.

Authors:  Alix Whelan; Elizabeth Williams; David R Nolan; Bruce Murphy; Paul S Gunning; David O'Reilly; Caitríona Lally
Journal:  Ann Biomed Eng       Date:  2020-10-15       Impact factor: 3.934

Review 3.  Is Bioprosthetic Valve Fracture Beneficial for Patients with Larger Surgical Valves Undergoing Valve in Valve TAVR?

Authors:  Adnan K Chhatriwalla; John T Saxon; David J Cohen; Keith B Allen
Journal:  Curr Cardiol Rep       Date:  2018-08-22       Impact factor: 2.931

Review 4.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

5.  Optimising the Haemodynamics of Aortic Valve-in-valve Procedures.

Authors:  Ren Jie Yao; Matheus Simonato; Danny Dvir
Journal:  Interv Cardiol       Date:  2017-05

6.  Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

Authors:  John T Saxon; Keith B Allen; David J Cohen; Adnan K Chhatriwalla
Journal:  Interv Cardiol       Date:  2018-01

7.  Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve.

Authors:  Yue Xuan; Kapil Krishnan; Jian Ye; Danny Dvir; Julius M Guccione; Liang Ge; Elaine E Tseng
Journal:  J Thorac Cardiovasc Surg       Date:  2016-12-23       Impact factor: 5.209

8.  Stent and Leaflet Stresses in 29-mm Second-Generation Balloon-Expandable Transcatheter Aortic Valve.

Authors:  Yue Xuan; Kapil Krishnan; Jian Ye; Danny Dvir; Julius M Guccione; Liang Ge; Elaine E Tseng
Journal:  Ann Thorac Surg       Date:  2017-04-12       Impact factor: 4.330

9.  Stent and leaflet stresses across generations of balloon-expandable transcatheter aortic valves.

Authors:  Yue Xuan; Danny Dvir; Zhongjie Wang; Jian Ye; Julius M Guccione; Liang Ge; Elaine E Tseng
Journal:  Interact Cardiovasc Thorac Surg       Date:  2020-06-01

10.  Rate-Dependent and Relaxation Properties of Porcine Aortic Heart Valve Biomaterials.

Authors:  Christopher Noble; Michael Kamykowski; Amir Lerman; Melissa Young
Journal:  IEEE Open J Eng Med Biol       Date:  2020-06-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.