Literature DB >> 32042226

Accuracy and reliability of spinal navigation: An analysis of over 1000 pedicle screws.

Dinesh Shree Kumar1, Nishanth Ampar2, Loo Wee Lim1.   

Abstract

PURPOSE: To estimate the rate of pedicle screw malpositioning associated with placing pedicle screws using intraoperative computed tomography (CT)-guided spinal navigation.
METHODS: We analysed the records of 219 patients who underwent pedicle screw fixation using O-arm-based navigation. Screw placement accuracy was evaluated on intraoperative CT scans acquired after pedicle screw insertion. Breaches were graded according to the Gertzbein classification (grade 0-III).
RESULTS: Of 1152 pedicle screws included, 47 had pedicle violations noted on intraoperative CT. Pedicle screw violation was noted for 17 of 241 screws placed in the cervical spine (overall breach rate, 7.05%; 3.73% and 3.3% with grade I and II, respectively), for 11 of 300 screws placed in the thoracic spine (overall breach rate, 3.67%; 2%, 1%, and 0.67% with grade I, II, and III, respectively), and for 22 of 611 screws placed in the lumbar spine (overall breach rate, 3.6%; 2.29% and 0.82% with grade I and II, respectively). The rate of accuracy of pedicle screw fixation was 93%, 96.33%, and 96.4% for the cervical, thoracic, and lumbar spine, respectively.
CONCLUSIONS: Using O-arm-based intra-operative three-dimensional scans for navigation can improve the reliability, accuracy, and safety of pedicle screw placement, reducing the risk for reoperation and hospitalization due to implant-related complications. Further improvement may be achieved by adequate consideration of potential sources of errors.
© 2019 Professor P K Surendran Memorial Education Foundation. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cortical perforation; Intraoperative computed tomography; O-arm navigation; Pedicle screw; Screw malposition

Year:  2019        PMID: 32042226      PMCID: PMC7000445          DOI: 10.1016/j.jor.2019.10.002

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  25 in total

1.  Accuracy requirements for image-guided spinal pedicle screw placement.

Authors:  Y R Rampersaud; D A Simon; K T Foley
Journal:  Spine (Phila Pa 1976)       Date:  2001-02-15       Impact factor: 3.468

2.  Three-dimensional fluoroscopy-guided percutaneous thoracolumbar pedicle screw placement. Technical note.

Authors:  Langston T Holly; Kevin T Foley
Journal:  J Neurosurg       Date:  2003-10       Impact factor: 5.115

Review 3.  Image-guided spinal surgery.

Authors:  Langston T Holly
Journal:  Int J Med Robot       Date:  2006-03       Impact factor: 2.547

4.  Spinal navigation: standard preoperative versus intraoperative computed tomography data set acquisition for computer-guidance system: radiological and clinical study in 100 consecutive patients.

Authors:  Francesco Costa; Andrea Cardia; Alessandro Ortolina; Galbusera Fabio; Alberto Zerbi; Maurizio Fornari
Journal:  Spine (Phila Pa 1976)       Date:  2011-11-15       Impact factor: 3.468

5.  Reliability of the Planned Pedicle Screw Trajectory versus the Actual Pedicle Screw Trajectory using Intra-operative 3D CT and Image Guidance.

Authors:  Catherine A Miller; Charles G Ledonio; Matthew A Hunt; Farhan Siddiq; David W Polly
Journal:  Int J Spine Surg       Date:  2016-10-24

6.  Accuracy of pedicular screw placement in vivo.

Authors:  S D Gertzbein; S E Robbins
Journal:  Spine (Phila Pa 1976)       Date:  1990-01       Impact factor: 3.468

7.  Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement.

Authors:  J N Weinstein; K F Spratt; D Spengler; C Brick; S Reid
Journal:  Spine (Phila Pa 1976)       Date:  1988-09       Impact factor: 3.468

8.  Placement of thoracolumbar pedicle screws using O-arm-based navigation: technical note on controlling the operational accuracy of the navigation system.

Authors:  Mario Ammirati; Asem Salma
Journal:  Neurosurg Rev       Date:  2012-09-07       Impact factor: 3.042

9.  A prospective multicenter registry on the accuracy of pedicle screw placement in the thoracic, lumbar, and sacral levels with the use of the O-arm imaging system and StealthStation Navigation.

Authors:  Erik Van de Kelft; F Costa; D Van der Planken; F Schils
Journal:  Spine (Phila Pa 1976)       Date:  2012-12-01       Impact factor: 3.468

10.  Pedicle violation and Navigational errors in pedicle screw insertion using the intraoperative O-arm: A preliminary report.

Authors:  Jacob E Mathew; Kelvin Mok; Benoit Goulet
Journal:  Int J Spine Surg       Date:  2013-12-01
View more
  1 in total

1.  Autonomous lumbar spine pedicle screw planning using machine learning: A validation study.

Authors:  Kris B Siemionow; Craig W Forsthoefel; Michael P Foy; Dominik Gawel; Christian J Luciano
Journal:  J Craniovertebr Junction Spine       Date:  2021-09-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.