Literature DB >> 3206294

Spinal pedicle fixation: reliability and validity of roentgenogram-based assessment and surgical factors on successful screw placement.

J N Weinstein1, K F Spratt, D Spengler, C Brick, S Reid.   

Abstract

The increased popularity of pedicle fixation prompted research to address two issues: the reliability and validity of roentgenograms as a technique for evaluating the success of pedicle fixation, and the effects of surgical factors on successful fixation. Thus, does approach--the point and angle of screw insertion, surgeon experience, practice, level of the spine involved, and screw size--effect success of pedicle fixation? Eight fresh thoracolumbar spines were harvested and cleaned of all soft tissues. Two surgeons, one more experienced in pedicle fixation than the other, used two pedicle fixation approaches (Weinstein and Roy-Camille) on both the left and right sides at levels T11-S1 of each specimen. All screws were placed under anteroposterior (AP) and lateral c-arm control. For specimens 1 to 3, 5.5 mm screws were used at T11-L1, and 7.0 mm screws at L2-S1. Unacceptable failure rates at L2 and L3 for the first three specimens resulted in a change of instrumentation for the remaining specimens, with 5.5 mm screws used at T11-L3 and 7.0 mm screws at L4-S1. When surgeons completed the fixations for a specimen, AP and lateral roentgenograms were taken and both surgeons independently evaluated the films to assess the success of each fixation. Failure was defined as evidence of any cortical perforation on any side of the pedicle in or outside of the spinal canal. After completing the roentgenogram evaluation, the specimen was transected in the midline, and the success of each pedicle fixation was evaluated by visual/tactile inspection. There were no disagreements between surgeons on the visual/tactile evaluations of the specimens.(ABSTRACT TRUNCATED AT 250 WORDS)

Mesh:

Year:  1988        PMID: 3206294     DOI: 10.1097/00007632-198809000-00008

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  82 in total

1.  CT-Guided Transfacet Pedicle Screw Fixation in Facet Joint Syndrome: A Novel Approach.

Authors:  Luigi Manfré
Journal:  Interv Neuroradiol       Date:  2014-10-17       Impact factor: 1.610

2.  [Iso-C(3D0-assisted) navigated implantation of pedicle screws in thoracic lumbar vertebrae].

Authors:  K Wendl; J von Recum; A Wentzensen; P A Grützner
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

3.  Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine.

Authors:  Marcus Richter; Thomas Mattes; Balkan Cakir
Journal:  Eur Spine J       Date:  2003-11-22       Impact factor: 3.134

4.  [Intraoperative three-dimensional navigation for pedicle screw placement].

Authors:  P A Grützner; T Beutler; K Wendl; J von Recum; A Wentzensen; L-P Nolte
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

5.  A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy.

Authors:  Christopher J Kleck; Ian Cullilmore; Matthew LaFleur; Emily Lindley; Mark E Rentschler; Evalina L Burger; Christopher M J Cain; Vikas V Patel
Journal:  Eur Spine J       Date:  2015-09-22       Impact factor: 3.134

6.  O-arm(®)-based spinal navigation and intraoperative 3D-imaging: first experiences.

Authors:  O Gonschorek; S Hauck; U Spiegl; T Weiß; R Pätzold; V Bühren
Journal:  Eur J Trauma Emerg Surg       Date:  2011-03-31       Impact factor: 3.693

7.  Pedicle Screw Placement in the Thoracolumbar Spine Using a Novel, Simple, Safe, and Effective Guide-Pin : A Computerized Tomography Analysis.

Authors:  Seung-Jae Hyun; Yongjung J Kim; Seung-Chul Rhim; Gene Cheh; Samuel K Cho
Journal:  J Korean Neurosurg Soc       Date:  2015-07-31

8.  Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine.

Authors:  Shiu-Bii Lien; Nien-Hsien Liou; Shing-Sheng Wu
Journal:  Eur Spine J       Date:  2006-12-19       Impact factor: 3.134

9.  Application of multislice spiral CT for guidance of insertion of thoracic spine pedicle screws: an in vitro study.

Authors:  Juan Wang; Yicheng Zhou; Ning Hu; Renfa Wang
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2006

10.  Intraoperative monitoring of segmental spinal nerve root function with free-run and electrically-triggered electromyography and spinal cord function with reflexes and F-responses. A position statement by the American Society of Neurophysiological Monitoring.

Authors:  Ronald E Leppanen
Journal:  J Clin Monit Comput       Date:  2006-01-25       Impact factor: 2.502

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.